Efficacy of C3F8 versus silicone oil tamponade in highly myopic macular hole retinal detachment
10.3980/j.issn.1672-5123.2024.5.27
- VernacularTitle:高度近视黄斑裂孔性视网膜脱离行玻璃体切割术后C3F8与硅油填充的疗效比较
- Author:
Xiaoying WEN
1
;
Na YANG
1
;
Yueling ZHANG
1
;
Weina MA
1
;
Yan FU
1
;
Renfei GENG
1
Author Information
1. Department of Ophthalmology, Baoding No.1 Central Hospital, Baoding 071000, Hebei Province, China
- Publication Type:Journal Article
- Keywords:
macular hole retinal detachment;
high myopia;
pars plana vitrectomy;
silicone oil tamponade;
C3F8 tamponade
- From:
International Eye Science
2024;24(5):805-809
- CountryChina
- Language:Chinese
-
Abstract:
AIM: To compare the outcome of C3F8 versus silicone oil tamponade after pars plana vitrectomy(PPV)and inverted internal limiting membrane(ILM)for the treatment of highly myopic macular hole retinal detachment(MHRD).METHODS: Retrospective clinical study. Totally 45 patients(45 eyes)with highly myopic MHRD who visited our hospital between January 2019 and August 2022 were selected as the research subjects. The patients were divided into two groups according to different intraocular tamponade agents: C3F8(22 eyes)and silicone oil(23 eyes)groups. All patients underwent conventional three-incision PPV, ILM was tamped, a venous blood clot was placed on the tamped ILM, and 15% C3F8 and silicone oil were used as tamponade, respectively. The best corrected visual acuity(BCVA), multifocal electroretinogram(mfERG), the closure of the macular hole, retinal reattachment and the complications were observed.RESULTS: The macular hole closure rate was 77% in the C3F8 group and 83% in the silicone oil group, respectively(P>0.05), and retinal reattachment rates were 95% and 96%, respectively(P>0.05). The visual acuity of the two groups significantly improved, which was 0.99±0.34 and 1.22±0.37, respectively, and the C3F8 group was better than that of the silicone oil group(t=-2.156, P=0.037). After operation, the response density of the first ring of P1 wave in the first order kernel in mfERG was 114.27±26.37 nV/deg2 for the C3F8 group and 98.08±24.36 nV/deg2 for the silicone oil group, and the response density of the second ring of P1 wave was 80.45±14.94 nV/deg2 for the C3F8 group and 67.73±15.33 nV/deg2 for the silicone oil group, all of which were significantly higher compared to pre-operation [the response density of the first ring of P1 wave: 58.13±13.96 nV/deg2 for the C3F8 group and 55.30±10.48 nV/deg2 for the silicone oil group, the response density of the second ring of P1 wave: 51.18±8.19 nV/deg2 for the C3F8 group and 47.43±11.97 nV/deg2 for the silicone oil group](all P<0.05). It was found that the response density of the first ring of P1 wave was lower in the silicone oil group than in the C3F8 group(P<0.05). There was no statistically significant difference in the incidence of complications between the two groups(P>0.05).CONCLUSION: Silicone oil tamponade or C3F8 tamponade after PPV combined with ILM can both promote retinal reattachment and macular hole closure in patients with MHRD, and the C3F8 tamponade was superior to silicone oil in visual function recovery.