- Keywords: drug concentration; ethyl acetate; human plasma; LC-MS/MS; liquid-liquid extraction; prucalopride
- From: Chinese Pharmacological Bulletin 2022;38(5):789-794
- CountryChina
- Language:Chinese
- Abstract: Aim To develop an LC-MS/MS method for the determination of prucalopride(PCP)in human plasma.Methods Prucalopride -13CD3(dPCP)was used as the internal standard.The analytes were extracted from human plasma through liquid-liquid extraction method using ethyl acetate, followed by being dried, and then the reconstitution was injected into LC-MS/MS systems.Agilent ZORBAX SB C18(3.0×100 mm, 3.5 μm)column and isocratic elution system composing of methanol and 1 mmol·L-1 ammonium acetate(80:20, V/V)provided chromatographic separation of PCP and dPCP.AB Sciex API4000 mass spectrometer equipped with an electrospray ionization source in positive ion mode was employed for mass detection, and data acquisition was carried out in multiple reaction monitoring(MRM)mode.The mass transition ion-pair was followed as m/z 368.4/196.0 for PCP and m/z 374.4/198.0 for dPCP.Results PCP and dPCP were eluted at 3.6 min, with no interference in human blank plasma.PCP in human plasma showed good linearity over the concentration range of 0.058 96-7.547 μg·L-1 with the correlation coefficient of 0.996 3-0.999 6.The lower limit of quantitation of this method was 0.058 96 μg·L-1.The intra-batch and inter-batch accuracy ranged from 98.29% to 108.2%, with good precision(CV<5.2%).The average matrix factors of normal, haemolysed and lipaemic matrix human samples all ranged from 96.48% to 106.3% with CV less than 8.39%.The average extraction recoveries of PCP at low, medium and high concentrations were 89.88%, 95.27% and 94.52% respectively, with CV less than 7.21%.PCP was stable in human samples after 6 h at room temperature, 60 h at -20 ℃, 56 days or three freeze-thaw cycles at -80 ℃; meanwhile, the processed plasma samples remained stable after being stored for 24 hours in autosampler at 8 ℃.Furthermore, PCP in human blood samples was proved to be stable after 4 h at room temperature.Conclusions The present LC-MS/MS method for the determination of PCP in human plasma was convenient, accurate, sensitive, stable, specific and reproducible and was proved to be suitable for the clinical pharmacokinetics and bioequivalence studies of PCP preparations.