Immunogenicity evaluation of prototype and variant inactivated SARS-CoV-2 vaccines in rats
10.13200/j.cnki.cjb.004172
- VernacularTitle:原型株及变异株SARS-CoV-2灭活疫苗在大鼠体内的免疫原性评价
- Author:
Kangwei XU
- Publication Type:Journal Article
- Keywords:
SARS-CoV-2;
Inactivated vaccine;
IgG antibody;
Neutralizing antibody
- From:
Chinese Journal of Biologicals
2024;37(3):263-266+272
- CountryChina
- Language:Chinese
-
Abstract:
Objective To evaluate the immunogenicity of prototype strain,Beta strain,Gamma strain and Delta strain of SARS-CoV-2 inactivated vaccines in rats.Methods Five female Wistar rats were immunized with SARS-CoV-2 inactivated vaccines of prototype,Beta,Gamma and Delta strains through thigh muscle twice at an interval of 14 d,with an immunization dose of 3 μg virus protein/(0.5 mL per rat).Serum samples were collected and isolated by vein 14,28 and 42 d after the first immunization.The serum IgG antibody levels were detected by indirect ELISA,the titers of serum neutralizing antibody were measured by microneutralization,and the antigenic ratios of the serum neutralizing antibody titers were calculated to evaluate the antigenicity difference between different strains.Results at 14 d after the first immunization,IgG antibodies against four strains of virus were detected in all immunized serum samples.The levels of IgG antibodies increased by more than 10 times at 28 d compared with those at 14 d,and decreased slightly at 42 d.At 14 d after the first immunization,all the neutralizing antibodies against the four strains were positive in the serum of rats immunized with prototype strain or Delta strain vaccine;In the serum samples of rats immunized with Beta and Gamma strains,all the neutralizing antibodies against Beta and Gamma strains were positive,while some neutralizing antibodies against prototype or Delta strains were positive.At 28 d after the first immunization,the neutralizing antibodies in the immune serum of the four strains were positive,and the titers of neutralizing antibodies were significantly higher than those at 14 d;The neutralizing antibody titers were slightly lower at 42 d after the first immunization than 28 d.There was small difference in the antigenicity between Beta and Gamma,prototype and Gamma,but significant difference in the antigenicity between prototype and Beta strains.Conclusion The prototype strain,Beta strain,Gamma strain and Delta strain of SARS-CoV-2 inactivated vaccines can stimulate rats to produce neutralizing antibodies with high titer,while the immunogenicity has difference.