Effect of noise on hearing loss among workers in a fastener manufacturing enterprise
10.19485/j.cnki.issn2096-5087.2023.11.009
- Author:
MENG Pan
;
WU Yikang
;
HU Zan
;
WU Daming
;
SHI Zhihao
;
ZHOU Zhehua
- Publication Type:Journal Article
- Keywords:
noise;
high-frequency noise-induced hearing loss;
speech-frequency noise-induced hearing loss;
fastener manufacturing
- From:
Journal of Preventive Medicine
2023;35(11):957-960, 965
- CountryChina
- Language:Chinese
-
Abstract:
Objective :To investigate the current status of hearing loss in a fastener manufacturing enterprise, and to analyze its influencing factors, so as to provide insights into occupational disease prevention and control.
Methods:The occupational health examination data of noise exposed workers and the workplace occupational disease hazard factors detection data in a fastener manufacturing enterprise in Jiaxing City in 2022 were collected through the Occupational Disease and Occupational Health Hazard Factors Detection System of China Disease Prevention and Control Information System, and factors affecting the development of high-frequency noise-induced hearing loss (HFNIHL) and speech-frequency noise-induced hearing loss (SFNIHL) were analyzed.
Results:Totally 625 workers were investigated, with a median age of 44.00 (interquartile range, 13.00) years and a median length of service of 8.00 (interquartile range, 9.00) years, and including 519 men (83.04%) and 106 women (16.96%). There were 309 workers with single noise exposure (49.44%) and 316 workers with joint noise exposure (50.56%), and 518 workers exposed to noise with the normalized continuous A-weighted sound pressure level equivalent to a 40 h working week (LEX,40 h) that exceeded the national standard (82.88%). The detection rates of HFNIHL and SFNIHL were 49.12% and 35.04%, respectively. Multivariable logistic regression analysis indicated that males (OR=10.528, 95%CI: 5.271-21.025), length of service of 10 years and longer (OR=2.451, 95%CI: 1.599-3.759), LEX,40 h of >85 dB (A) (OR=2.227, 95%CI: 1.318-3.764) and joint noise exposure (OR=3.002, 95%CI: 2.080-4.334) were associated with an increased risk of HFNIHL, and male (OR=9.400, 95%CI: 4.211-20.985), LEX,40 h of >85 dB (A) (OR=2.305, 95%CI: 1.345-3.951), and joint noise exposure (OR=3.880, 95%CI: 2.677-5.623) were associated with an increased risk of SFNIHL.
Conclusion:Gender, length of service, noise intensity and exposure mode are factors affecting the risk of HFNIHL, while gender, noise intensity and exposure mode are factors affecting the risk of SFNIHL.
- Full text:紧固件制造企业噪声对作业工人听力损失的影响研究.pdf