Evaluation of early binocular visual function after implantable collamer lens V4c implantation in patients with high myopia
10.3980/j.issn.1672-5123.2024.4.26
- VernacularTitle:高度近视患者ICL V4c植入术后早期双眼视觉功能评估
- Author:
Kaili TANG
1
,
2
,
3
;
Jing WANG
1
,
2
,
3
;
Zhenbo ZHAO
1
,
2
,
3
;
Dong HAN
1
,
2
,
3
;
Yuxi DING
1
,
2
,
3
;
Jinsong ZHANG
1
,
2
,
3
;
Liwei MA
1
,
2
,
3
Author Information
1. Aier Eye Hospital Affiliated to Anhui Medical University, Hefei 230031, Anhui Province, China
2. Shenyang Aier Excellence Eye Hospital, Shenyang 110000, Liaoning Province, China
3. Aier Eye Institute of Cataract and Intraocular Lens, Shenyang 110000, Liaoning Province, China
- Publication Type:Journal Article
- Keywords:
high myopia;
implantable collamer lens V4c(ICL V4c);
binocular visual function
- From:
International Eye Science
2024;24(4):634-640
- CountryChina
- Language:Chinese
-
Abstract:
AIM: To evaluate the binocular visual function in high myopia patients after the implantation of implantable collamer lens(ICL)V4c.METHODS: A total of 35 cases(70 eyes)that received binocular ICL implantation at our hospital from May 2019 to May 2021 were enrolled in this prospective study. Binocular full-range visual acuity, contrast sensitivity, stereopsis, mesopic vision and glare sensitivity, and monocular wavefront and the quality of vision questionnaire were assessed before the surgery and at 1 mo postoperatively.RESULTS: At 1 mo postoperatively, 35 cases(100%)had binocular uncorrected distance visual acuity(UDVA)≤0.00(LogMAR), 16 cases(46%)had binocular UDVA≥preoperative corrected distance visual acuity(CDVA). Binocular UDVA and uncorrected intermediate visual acuity(UIVA,80 cm)were improved compared to preoperative CDVA and distance-corrected intermediate visual acuity(DCIVA,80 cm)(all P<0.05).While there were no differences in the binocular postoperative UIVA(60 cm)and preoperative DCIVA(60 cm),and uncorrected near visual acuity(UNVA,40 cm)and preoperative distance-corrected near visual acuity(DCNVA,40 cm)(all P>0.05). The binocular contrast sensitivity was significantly improved postoperatively(P=0.001), and the postoperative binocular mesopic vision, glare sensitivity(no glare/glare)and binocular stereopsis(5 m/40 cm)had no differences(all P>0.05). The postoperative total higher-order aberration, trefoil aberration, coma and spherical aberration were increased, besides the median of total coma in the right eye with a pupil diameter of 3.0 mm was decreased after surgery. The mean total score of quality of vision questionnaire was significantly increased from 54.87 preoperatively to 80.92 after implantation(P<0.05), with high satisfaction and no obvious visual disturbance in patients.CONCLUSION: Although the monocular high-order aberrations increased in the early stage after ICL V4c binocular implantation in patients with high myopia, the binocular visual function was improved.