Comparison of Forefinger Tapping between Hemiplegics and Normal Controls
- VernacularTitle:偏瘫患者健侧食指摆动频率与健康者的比较
- Author:
Ling-li ZHANG
;
Zhu-sheng YU
- Publication Type:Journal Article
- Keywords:
hemiplegia, unaffected hand, finger tapping
- From:
Chinese Journal of Rehabilitation Theory and Practice
2012;18(12):1107-1108
- CountryChina
- Language:Chinese
-
Abstract:
Objective To measure the tapping frequency of hemiplegic unaffected forefinger and normal control's forefinger. Methods The tapping frequency of 27 left hemiplegic patients and 32 healthy controls were measured by finger oscillating frequency tester. Results The oscillation frequency of hemiplegic patients was lower than that of the healthy controls (P<0.001). Conclusion Hand function of hemiplegic patients weakened.