Abstract:
【Objective】 To investigate the effectiveness of current indicators in initial screening and retest before donation and access the optimal testing strategies. 【Methods】 Data of initial screening (rate method for ALT, colloidal gold method for HBsAg) and retest (rate method for ALT, ELISA for HBsAg) of 18 510 platelet donors in our center from January 2019 to December 2021 were collected, and the results were retrospectively analyzed and compared in terms of different years and number of donations. 【Results】 From 2019 to 2021, data of initial screening and retest of platelet donors were as follows: 1) the deferral rate of ALT and HBsAg was 12.98% (2 403/18 510) vs 0.26%(40/15 412); 2) the deferral rate of ALT was 13.19% (712/5 398) vs 0.20%(9/4 410)in 2019, 13.33% (873/6 549) vs 0.06%(3/5 387)in 2020 and 11.05% (725/6 563) vs 0.07%(4/5 615)in 2021; for initial screening, significant difference was noticed in ALT reactivity in 2021 as in comparison to other two years(P<0.05); 3) the reactive rate of HBsAg was 0.43% (23/5 398) vs 0.18%(8/4 410)in 2019, 0.66% (43/6 549) vs 0.20%(11/5 387)in 2020 and 0.41% (27/6 563) vs 0.09%(5/5, 615) in 2021. For initial screening, HBsAg deferral in 2021 was significantly different from 2019, while similar with 2020. 4) Among ALT deferral samples in the retest, 68.75% (11/16) were ALT≥45 U/L. Among HBsAg reactive samples, 91.67% (22/24) were reactive by single reagent. 【Conclusion】 Setting the threshold value of ALT for platelet donors in initial screening as less than 45 U/L can effectively reduce the reactive rate in the retest. HBsAg screening only for first-time platelet donors can reduce the detection cost. Adding pre-donation detection indicators according to local prevalence of transfusion transmitted diseases is conductive to reduce the discarding rate of platelets.