Analysis of the impact of setting up plasmapheresis station on the collection volume of voluntary blood donation based on panel vector autoregressive model
10.13303/j.cjbt.issn.1004-549x.2023.07.015
- VernacularTitle:基于面板向量自回归模型分析单采血浆站设置对无偿献血采集量的冲击
- Author:
Wan LI
1
;
Guanglin XIAO
1
;
Changqing LI
1
;
Yongjun CHEN
1
;
Yong WANG
2
;
Jing HUANG
3
;
Xiaojun MA
4
;
Shouqiang YANG
4
;
Fei CHEN
5
;
Ya WANG
1
Author Information
1. Institute of Blood Transfusion, Chinese Academy of Medical Sciences & Peking Union Medical College, Chengdu 610052, China
2. Guangyuan Blood Center
3. Sichuan Yuanda Shuyang Pharmaceutical Co., Ltd
4. Jiange Plasmapheresis Station, Sichuan Yuanda Shuyang Pharmaceutical Company Limited
5. Cangxi Plasmapheresis Station, Sichuan Yuanda Shuyang Pharmaceutical Company Limited
- Publication Type:Journal Article
- Keywords:
panel vector autoregressive model;
plasmapheresis station;
voluntary blood donation;
Guangyuan
- From:
Chinese Journal of Blood Transfusion
2023;36(7):618-622
- CountryChina
- Language:Chinese
-
Abstract:
【Objective】 To analyze the dynamic relationship between the setting up of plasmapheresis station and the volume of voluntary blood donation collected using panel vector autoregressive model, so as to provide scientific reference for the management policies of blood stations and plasmapheresis stations in China. 【Methods】 The data collected from blood stations in seven administrative regions of Guangyuan, Sichuan Province from 2011 to 2021, as well as plasma collection data from two plasmapheresis stations in the region within two years since their operation, were collected. A panel vector autoregressive model was constructed. Impulse response analysis and variance decomposition analysis were used to analyze the impact and time lag effects of simulated plasmapheresis station settings on the collection volume of voluntary blood donation. Covariance analysis was used to explore whether the establishment of plasmapheresis station had an impact on the volume of voluntary blood donation collected after excluding the impact of initial value differences. 【Results】 The pulse response results showed that after the plasmapheresis station was set up, there was a negative impact effect on the voluntary blood donation collection volume at the first stage, and its impact began to rise after the second stage, reached the highest value in the third stage, and then began to decline. After the seventh stage, it tended to be stable. However, within the 10 stage range, the confidence interval for the response strength of voluntary blood donation collection volume always included 0, indicating that the response of blood collection volume to the plasmapheresis station setting in the region was not statistically significant. The results of variance decomposition showed that the contribution of collection volume of voluntary blood donation to their own impact reached 94.3%. In terms of the contribution of plasmapheresis station factors, the number of plasma donors has a relatively greater impact on the volume of voluntary blood donation collected(2.2%). Covariance analysis showed that after removing the initial confounding factors, whether to establish a plasmapheresis station had no significant impact on blood donation volume in the two groups of regions (P>0.05). 【Conclusion】 The establishment of a new plasmapheresis station will have a certain impact on blood collection volume of blood stations in the region in a short term, but in the long term, it may not directly affect the voluntary blood donation collection in the region.