Application of intelligent closed-loop mobile nursing management system in quality management of blood transfusion
10.13303/j.cjbt.issn.1004-549x.2021.04.026
- VernacularTitle:智慧型闭环移动护理管理系统在临床用血质量管理中的应用
- Author:
Yeling ZHANG
1
;
Xiaojia BU
1
;
Jinglian ZHANG
1
;
Changyan SHAO
1
;
Shuchao ZHANG
2
Author Information
1. Department of Hematology, The Affiliated Hospital of Qingdao University, Qingdao 266003, China
2. Department of Blood Transfusion, The Affiliated Hospital of Qingdao University, Qingdao 266003, China
- Publication Type:Journal Article
- Keywords:
blood transfusion nursing;
mobile nursing management system;
intelligent closed-loop management;
safety of clinical blood use;
quality management of blood transfusion
- From:
Chinese Journal of Blood Transfusion
2021;34(4):420-423
- CountryChina
- Language:Chinese
-
Abstract:
【Objective】 To explore the effect of intelligent closed-loop mobile nursing management system in quality management of blood transfusion. 【Methods】 The mobile nursing system and the cold chain management system of our hospital were integrated to realize intelligent closed-loop management of blood transfusion. After consulting medical records, 789 blood recipients, admitted to the Department of Hematology of our hospital from January to December 2017 (before the implementation of closed-loop management), were selected as the control group, and 836 blood recipients, admitted during January to December 2018 (after the implementation of closed-loop management), were selected as the observation group. A self-designed blood transfusion standard management checklist was adopted, with the number of standard execution items as the numerator and the total number of checked items as the denominator to obtain the standard implementation rate. The checking rate of blood sample collection, blood transfusion rate within 30 min after blood issuing, the execution rate of double check specification and inspection specification, the completion rate of RBCs transfusion within 4 h and qualified rate of blood transfusion nursing record before and after the implementation of closed-loop management were compared by chi-square test or Fisher's exact probability method to evaluate the efficacy of blood quality management improvement. A total of 8 head nurses from clinical departments (Hematology Department, Cardiac Surgery Department, Operating Room, Comprehensive ICU) involved in blood transfusion were selected for semi-structured interviews. The interviews focused on the effect of intelligent closed-loop mobile nursing information system in quality management of clinical blood use, and the results of the interviews were analyzed. 【Results】 The double check execution rate of blood transfusion, the checking rate of blood sample collection specification, the transfusion rate within 30 min after blood issuing, the execution rate of blood transfusion inspection, the completion rate of RBCs transfusion within 4 h, the qualified rate of blood transfusion nursing record in the observation group and the control group after and before the implication of the intelligent closed-loop mobile nursing management system were 100%(836/836) vs 97.72%(771/789), 99.04%(828/836) vs 97.34%(768/789), 97.97%(819/836) vs 95.06%(750/789), 99.28%(830/836) vs 94.93%(712/789), 99.16%(829/836) vs 97.47%(769/789) and 100%(836/836) vs 89.73%(708/789), respectively, showing significant improvement (P < 0.05). The time spend on the record, summary and feedback of quality control results was significantly shortened. 【Conclusion】 The application of intelligent closed-loop mobile nursing management system in the quality management of clinical blood use can effectively improve the efficiency of blood transfusion, nursing quality and the safety of clinical blood use.