Cause analysis and prevention of wrong connection between anticoagulant and normal saline solution during apheresis platelet donation
10.13303/j.cjbt.issn.1004-549x.2022.02.024
- VernacularTitle:血细胞分离机单采过程抗凝剂和生理盐水连接错误原因分析及预防
- Author:
Shuhua JI
1
;
Shuming HUANG
1
;
Huiwei TANG
1
;
Cen CHEN
1
;
Xiaoling CHU
1
Author Information
1. Fujian Blood Center, Fuzhou 350004, China
- Publication Type:Journal Article
- Keywords:
apheresis platelets;
solution connect;
information system;
auxiliary calibration
- From:
Chinese Journal of Blood Transfusion
2022;35(2):219-221
- CountryChina
- Language:Chinese
-
Abstract:
【Objective】 To explore the reasons for wrong connection between anticoagulant and normal saline solution during apheresis platelet donation, as well as the preventive measures, so as to ensure the safety of apheresis platelet donors. 【Methods】 Manual checking in the first phase (December 2008 to September 2016) was compared with double checking (manual checking plus information system) in the second phase (October 2016 to October 2020) via bilateral testing using Fisher's Exact Test to study pre-post-improvement differences. 【Results】 The incidence of solution connection errors during apheresis platelet donation in the first phase was 1.02/10 000, and the error incidence between Amicus and Trima + Mcs®+ blood cell separator was statistically significant (P<0.05). The total incidence of errors between the first and second phases was not statistically significant (P>0.05). After the performance of double checking in the second phase, no wrong connection of anticoagulant and saline solution occurred. 【Conclusion】 The double checking method assisted by manual and information system can effectively prevent the wrong connection between anticoagulant and normal saline solution.