1.Porcelain repair - Influence of different systems and surface treatments on resin bond strength.
Ji Young YOO ; Hyung In YOON ; Ji Man PARK ; Eun Jin PARK
The Journal of Advanced Prosthodontics 2015;7(5):343-348
PURPOSE: The purpose of this study was to evaluate the bond strength of composite resin on the fracture surface of metal-ceramic depending on the repair systems and surface roughening methods. MATERIALS AND METHODS: A total of 30 disk specimens were fabricated, 15 of each were made from feldspathic porcelain and nickel-chromium base metal alloy. Each substrate was divided into three groups according to the repair method: a) application of repair system I (Intraoral Repair Kit) with diamond bur roughening (Group DP and DM), b) application of repair system I with airborne-particle abrasion (Group SP and SM), and c) application of repair system II (CoJet Intraoral Repair System, Group CP and CM). All specimens were thermocycled, and the shear bond strength was measured. The data were analyzed using the Kruskal-Wallis analysis and the Mann-Whitney test with a significance level of 0.05. RESULTS: For the porcelain specimens, group SP showed the highest shear bond strength (25.85 +/- 3.51 MPa) and group DP and CP were not significantly different. In metal specimens, group CM showed superior values of bond strength (13.81 +/- 3.45 MPa) compared to groups DM or SM. CONCLUSION: Airborne-particle abrasion and application of repair system I can be recommended in the case of a fracture localized to the porcelain. If the fracture extends to metal surface, the repair system II is worthy of consideration.
Alloys
;
Dental Instruments
;
Dental Porcelain*
2.Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis.
Seok Gyu KIM ; Chae Heon CHUNG ; Mee Kyoung SON
The Journal of Advanced Prosthodontics 2015;7(3):207-213
PURPOSE: The purpose of this study was to examine the abutment screw stability of screw- and cement-retained implant-supported dental prosthesis (SCP) after simulated cement washout as well as the stability of SCP cements after complete loosening of abutment screws. MATERIALS AND METHODS: Thirty-six titanium CAD/CAM-made implant prostheses were fabricated on two implants placed in the resin models. Each prosthesis is a two-unit SCP: one screw-retained and the other cemented. After evaluating the passive fit of each prosthesis, all implant prostheses were randomly divided into 3 groups: screwed and cemented SCP (Control), screwed and noncemented SCP (Group 1), unscrewed and cemented SCP (Group 2). Each prosthesis in Control and Group 1 was screwed and/or cemented, and the preloading reverse torque value (RTV) was evaluated. SCP in Group 2 was screwed and cemented, and then unscrewed (RTV=0) after the cement was set. After cyclic loading was applied, the postloading RTV was measured. RTV loss and decementation ratios were calculated for statistical analysis. RESULTS: There was no significant difference in RTV loss ratio between Control and Group 1 (P=.16). No decemented prosthesis was found among Control and Group 2. CONCLUSION: Within the limits of this in vitro study, the stabilities of SCP abutment screws and cement were not significantly changed after simulated cement washout or screw loosening.
Dental Cements
;
Dental Prosthesis, Implant-Supported*
;
Prostheses and Implants
;
Titanium
;
Torque
3.Impact of surface roughness of gypsum materials on adaptation of zirconia cores.
Ki Baek KIM ; Jae Hong KIM ; Sa Hak KIM
The Journal of Advanced Prosthodontics 2015;7(3):199-206
PURPOSE: The present study investigated the influences of various gypsum materials on the precision of fit of CAD/CAM-fabricated prostheses and analyzed their correlation with surface roughness. MATERIALS AND METHODS: The master model of the mandibular right first molar was replicated, and four experimental groups based on two types of Type IV stone (GC Fujirock EP, Die keen) and two types of scannable stone (Aesthetic-Basegold, Everest Rock) were created to include a total of 40 specimens, 10 in each group. The surface roughness of the working models for the respective experimental groups was measured. Once the zirconia cores had been fabricated, the marginal and internal fits were measured with a digital microscope using the silicone replica technique. The mean and standard deviation of the respective points of measurement were computed and analyzed through the one-way ANOVA and Tukey's HSD test. The correlation between surface roughness and the precision of fit of the zirconia core was analyzed using the Pearson correlation analysis (alpha=.05). RESULTS: The zirconia cores fabricated from the scannable stone working models exhibited a superior precision of fit as compared to those fabricated from the Type IV stone working models. The correlation analysis results showed a clear positive correlation between surface roughness and the precision of fit of zirconia cores in all of the experimental groups (P<.05). CONCLUSION: The results confirmed that the surface roughness of dental working models has a decisive influence on the precision of fit of zirconia cores.
Calcium Sulfate*
;
Molar
;
Prostheses and Implants
;
Replica Techniques
;
Silicones
4.Comparison of marginal bone loss and patient satisfaction in single and double-implant assisted mandibular overdenture by immediate loading.
Sara TAVAKOLIZADEH ; Fariborz VAFAEE ; Masume KHOSHHAL ; Zahra EBRAHIMZADEH
The Journal of Advanced Prosthodontics 2015;7(3):191-198
PURPOSE: The purpose of this study was to compare the coronal bone level and patient satisfaction in 1-implant and 2-implant assisted mandibular overdentures. MATERIALS AND METHODS: Twenty patients who had maladaptive mandibular dentures were treated in this study. Patients were randomly divided into two groups. The first group received 1 implant (Simple line II, Implantium, South Korea) in their mandibular midline and the second group received 2 implants in their B and D regions (according to Misch's category). If the primary stability of each implant was at least 60 ISQ, ball attachment was placed and denture relined with soft liner. After 6 weeks, retentive cap incorporated with hard acrylic resin. In the 6 and 12 months recalls, periapical digital radiograph were made and visual analogue scale questionnaires were used to record patient satisfaction. The Friedman test was done for comparing the presurgical and postsurgical parameters in each group and the U-Mann Whitney test (P<.05) was done for comparison of post-treatment results between the two groups. RESULTS: All implants achieved sufficient primary stability to be immediately loaded. Patient satisfaction was high, and there were no significant differences between two groups (P>.05). In addition, mean marginal bone loss was 0.6 +/- 0.67 mm in the first group and 0.6 +/- 0.51 mm in the second group, after 12 month. Mean marginal bone loss showed no significant differences between two groups. CONCLUSION: This preliminary one-year result indicated that mandibular overdentures anchored to a single implant can be a safe and cost-effective method as a starting step for implant-overdenture treatment.
Denture, Overlay*
;
Dentures
;
Humans
;
Patient Satisfaction*
;
Surveys and Questionnaires
5.Influence of preparation depths on the fracture load of customized zirconia abutments with titanium insert.
Han Sung JOO ; Hong So YANG ; Sang Won PARK ; Hyun Seung KIM ; Kwi Dug YUN ; Min Kyung JI ; Hyun Pil LIM
The Journal of Advanced Prosthodontics 2015;7(3):183-190
PURPOSE: This study evaluated the fracture load of customized zirconia abutments with titanium insert according to preparation depths, with or without 5-year artificial aging. MATERIALS AND METHODS: Thirty-six identical lithium disilicate crowns (IPS e.max press) were fabricated to replace a maxillary right central incisor and cemented to the customized zirconia abutment with titanium insert on a 4.5x10 mm titanium fixture. Abutments were fabricated with 3 preparation depths (0.5 mm, 0.7 mm, and 0.9 mm). Half of the samples were then processed using thermocycling (temperature: 5-55degrees C, dwelling time: 120s) and chewing simulation (1,200,000 cycles, 49 N load). All specimens were classified into 6 groups depending on the preparation depth and artificial aging (non-artificial aging groups: N5, N7, N9; artificial aging groups: A5, A7, A9). Static load was applied at 135 degrees to the implant axis in a universal testing machine. Statistical analyses of the results were performed using 1-way ANOVA, 2-way ANOVA, independent t-test and multiple linear regression. RESULTS: The fracture loads were 539.28 +/- 63.11 N (N5), 406.56 +/- 28.94 N (N7), 366.66 +/- 30.19 N (N9), 392.61 +/- 50.57 N (A5), 317.94 +/- 30.05 N (A7), and 292.74 +/- 37.15 N (A9). The fracture load of group N5 was significantly higher than those of group N7 and N9 (P<.017). Consequently, the fracture load of group A5 was also significantly higher than those of group A7 and A9 (P<.05). After artificial aging, the fracture load was significantly decreased in all groups with various preparation depths (P<.05). CONCLUSION: The fracture load of a single anterior implant restored with lithium disilicate crown on zirconia abutment with titanium insert differed depending on the preparation depths. After 5-year artificial aging, the fracture loads of all preparation groups decreased significantly.
Aging
;
Axis, Cervical Vertebra
;
Crowns
;
Dental Implants
;
Incisor
;
Linear Models
;
Lithium
;
Mastication
;
Titanium*
6.Rehabilitation of a patient with non-syndromic partial oligodontia.
Hyeon Goo KANG ; Yoon Hyuk HUH ; Chan Jin PARK ; Lee Ra CHO
The Journal of Advanced Prosthodontics 2016;8(3):241-250
Oligodontia is defined as a congenital tooth agenesis with the absence of six or more permanent teeth. This clinical report describes a patient with non-syndromic partial oligodontia, with retained deciduous teeth and the absence of 16 permanent teeth. Anterior esthetic problems were caused by interarch tooth size discrepancy, interdental space, aberrant tooth dimensions, and the absence of centric contacts of the anterior teeth. Prosthetic restoration after orthodontic and implant treatment was performed with a multi-disciplinary team approach. Favorable functional and esthetic results were obtained using a definitive prosthesis.
Humans
;
Prostheses and Implants
;
Rehabilitation*
;
Tooth
;
Tooth, Deciduous
7.Comparison of alkaline phosphatase activity of MC3T3-E1 cells cultured on different Ti surfaces: modified sandblasted with large grit and acid-etched (MSLA), laser-treated, and laser and acid-treated Ti surfaces.
Lin Jie LI ; So Nam KIM ; Sung Am CHO
The Journal of Advanced Prosthodontics 2016;8(3):235-240
PURPOSE: In this study, the aim of this study was to evaluate the effect of implant surface treatment on cell differentiation of osteoblast cells. For this purpose, three surfaces were compared: (1) a modified SLA (MSLA: sand-blasted with large grit, acid-etched, and immersed in 0.9% NaCl), (2) a laser treatment (LT: laser treatment) titanium surface and (3) a laser and acid-treated (LAT: laser treatment, acid-etched) titanium surface. MATERIALS AND METHODS: The MSLA surfaces were considered as the control group, and LT and LAT surfaces as test groups. Alkaline phosphatase expression (ALP) was used to quantify osteoblastic differentiation of MC3T3-E1 cell. Surface roughness was evaluated by a contact profilometer (URFPAK-SV; Mitutoyo, Kawasaki, Japan) and characterized by two parameters: mean roughness (Ra) and maximum peak-to-valley height (Rt). RESULTS: Scanning electron microscope revealed that MSLA (control group) surface was not as rough as LT, LAT surface (test groups). Alkaline phosphatase expression, the measure of osteoblastic differentiation, and total ALP expression by surface-adherent cells were found to be highest at 21 days for all three surfaces tested (P<.05). Furthermore, ALP expression levels of MSLA and LAT surfaces were significantly higher than expression levels of LT surface-adherent cells at 7, 14, and 21 days, respectively (P<.05). However, ALP expression levels between MSLA and LAT surface were equal at 7, 14, and 21 days (P>.05). CONCLUSION: This study suggested that MSLA and LAT surfaces exhibited more favorable environment for osteoblast differentiation when compared with LT surface, the results that are important for implant surface modification studies.
Alkaline Phosphatase*
;
Cell Differentiation
;
Osteoblasts
;
Titanium
8.Analysis of maxillofacial prosthetics at university dental hospitals in the capital region of Korea.
Jee Hwan KIM ; Soo Yeon SHIN ; Janghyun PAEK ; Jong Ho LEE ; Ho Beom KWON
The Journal of Advanced Prosthodontics 2016;8(3):229-234
PURPOSE: The purpose of this study was to investigate the demographic patterns of maxillofacial prosthetic treatment to identify the characteristics and geographic distribution of patients with maxillofacial prosthetics in the capital region of Korea. MATERIALS AND METHODS: This retrospective analytical multicenter study was performed by chart reviews. This study included patients who visited the department of prosthodontics at four university dental hospitals for maxillofacial prosthetic rehabilitation. Patients with facial and congenital defects or with insufficient medical data were excluded. The patients were classified into three categories based on the location of the defect. Patients' sex, age, and residential area were analyzed. Pearson's chi-square test with a significance level of 0.05 was used to analyze the variables. RESULTS: Among 540 patients with maxillofacial prosthetics, there were 284 (52.59%) male patients and 256 (47.41%) female patients. The number of the patients varied greatly by hospital. Most patients were older than 70, and the most common defect was a hard palate defect. Chi-square analysis did not identify any significant differences in sex, age, and distance to hospital for any defect group (P>.05). CONCLUSION: The results of this study indicated that there was imbalance in the distribution of patients with maxillofacial prosthetic among the hospitals in the capital region of Korea. Considerations on specialists and insurance policies for the improvement of maxillofacial prosthetics in Korea are required.
Congenital Abnormalities
;
Female
;
Head and Neck Neoplasms
;
Humans
;
Insurance
;
Korea*
;
Male
;
Mandibular Prosthesis
;
Maxillofacial Prosthesis
;
Palatal Obturators
;
Palate, Hard
;
Prosthodontics
;
Rehabilitation
;
Retrospective Studies
;
Specialization
;
Velopharyngeal Insufficiency
9.Effect of dentin surface roughness on the shear bond strength of resin bonded restorations.
Roodabeh KOODARYAN ; Ali HAFEZEQORAN ; Sajjad POURSOLTAN
The Journal of Advanced Prosthodontics 2016;8(3):224-228
PURPOSE: This study aimed to investigate whether dentin surface preparation with diamond rotary instruments of different grit sizes affects the shear bond strength of resin-bonded restorations. MATERIALS AND METHODS: The buccal enamel of 60 maxillary central incisors was removed with a low speed diamond saw and wet ground with silicon carbide papers. The polished surfaces of the teeth were prepared with four groups of rotary diamond burs with super-coarse (SC), coarse (C), medium (M), and fine (F) grit sizes. Following surface preparation, 60 restorations were casted with nickel-chromium alloy and bonded with Panavia cement. To assess the shear bond strength, the samples were mounted on a universal testing machine and an axial load was applied along the cement-restoration interface at the crosshead speed of 0.5 mm/min. The acquired data was analyzed with one way ANOVA and Tukey post hoc test (α=.05). RESULTS: The mean ± SD shear bond strengths (in MPa) of the study groups were 17.75 ± 1.41 for SC, 13.82 ± 1.13 for C, 10.40 ± 1.45 for M, and 7.13 ± 1.18 for F. Statistical analysis revealed the significant difference among the study groups such that the value for group SC was significantly higher than that for group F (P<.001). CONCLUSION: Dentin surface roughness created by diamond burs of different grit sizes considerably influences the shear bond strength of resin bonded restorations.
Alloys
;
Dental Enamel
;
Dental Instruments
;
Dentin*
;
Denture, Partial, Fixed, Resin-Bonded
;
Diamond
;
Incisor
;
Shear Strength
;
Silicon
;
Tooth
10.Creating a digitized database of maxillofacial prostheses (obturators): A pilot study.
Mahmoud ELBASHTI ; Mariko HATTORI ; Yuka SUMITA ; Amel ASWEHLEE ; Shigen YOSHI ; Hisashi TANIGUCHI
The Journal of Advanced Prosthodontics 2016;8(3):219-223
PURPOSE: This study aimed to create a digitized database of fabricated obturators to be kept for patients' potential emergency needs. MATERIALS AND METHODS: A chairside intraoral scanner was used to scan the surfaces of an acrylic resin obturator. The scanned data was recorded and saved as a single standard tessellation language file using a three-dimensional modeling software. A simulated obturator model was manufactured using fused deposition modeling technique in a three-dimensional printer. RESULTS: The entire obturator was successfully scanned regardless of its structural complexity, modeled as three-dimensional data, and stored in the digital system of our clinic at a relatively small size (19.6 MB). A simulated obturator model was then accurately manufactured from these data. CONCLUSION: This study provides a proof-of-concept for the use of digital technology to create a digitized database of obturators for edentulous maxillectomy patients.
Emergencies
;
Humans
;
Maxillofacial Prosthesis*
;
Pilot Projects*