1.The level of buccal gingival margin around single and two adjacent implant restorations: a preliminary result.
Young Bum KIM ; June Sung SHIM ; Chong Hyun HAN ; Sun Jai KIM
The Journal of Advanced Prosthodontics 2009;1(3):140-144
STATEMENT OF PROBLEM: Little information is available about the buccal gingival level of multiple implant restorations. PURPOSE: This study was aimed to evaluate the relationship between width and height of buccal soft tissue around single and 2 adjacent implant restorations. MATERIAL AND METHODS: Four implant restoration groups (first and second molars, single second molars, posterior single restorations between teeth, and anterior single restorations between teeth) were randomly chosen from one dental institute. Each group comprised of 6 patients. After 6 months of function, silicone impressions were taken and stone models were fabricated for each restoration group. The stone models were cut in bucco-lingual direction at the most apical point of buccal gingival margin. The height and width of buccal supra-implant soft tissue were measured. One way ANOVA and Tukey HSD post hoc tests were performed to analyze the data obtained (P < .05). RESULTS: The most unfavorable width-height ratio was noted for the group, which was comprised of the second molar in the multiple adjacent (first and second molar) implant-supported restorations. The group also resulted in the shorter height of buccal supra-implant mucosa rather than that of anterior single implant restorations between natural teeth. CONCLUSION: To achieve a favorable level of buccal gingival margin, greater thickness of buccal supra-implant mucosa is required for the implant restorations without a neighboring natural tooth compared to the implant restorations next to a natural tooth.
Humans
;
Molar
;
Mucous Membrane
;
Silicones
;
Tooth
2.Results of immediate loading for implant restoration in partially edentulous patients: a 6-month preliminary prospective study using SinusQuick(TM) EB implant system.
Jong Hwa KIM ; Young Kyun KIM ; Yang Jin YI ; Pil Young YUN ; Hyo Jung LEE ; Myung Jin KIM ; In Sung YEO
The Journal of Advanced Prosthodontics 2009;1(3):136-139
STATEMENT OF PROBLEM: Many dental clinicians are concerned about immediate loading of inserted implants. However, there have been few clinical studies surveying the success rates of immediate loading, based on Korean implant systems. PURPOSE: The aim of this study was to evaluate the outcome of immediate functional loading of the implant (SinusQuick(TM) EB, Neobiotech Co., Seoul, Korea) in partially edentulous maxilla or mandible. MATERIAL AND METHODS: Total 15 implants were placed. Within 2 weeks after implant insertion, provisional implant-supported fixed partial dentures were delivered to the patients. Quantitatively, marginal bone loss was measured at the time of immediate loading, after 3-months of continued loading and at the last follow-up. The mean follow-up period was 4.8 months. RESULTS: Mean marginal bone loss from implant surgery to early loading, 3-months follow-up and last follow-up was 0.03 +/- 0.07 mm, 0.16 +/- 0.17 mm and 0.29 +/- 0.19 mm. No implant failed up to 6 months after insertion, resulting in a 100% survival rate. CONCLUSION: Immediate loading exhibited high success rate in partial edentulism for up to 6 months. Well-controlled long term clinical studies with large sample size are necessary to confirm this finding.
Dental Implants
;
Denture, Partial, Fixed
;
Follow-Up Studies
;
Humans
;
Mandible
;
Maxilla
;
Prospective Studies
;
Sample Size
;
Survival Rate
3.Shear bond strength of veneering porcelain to zirconia and metal cores.
Bu Kyung CHOI ; Jung Suk HAN ; Jae Ho YANG ; Jai Bong LEE ; Sung Hun KIM
The Journal of Advanced Prosthodontics 2009;1(3):129-135
STATEMENT OF PROBLEM: Zirconia-based restorations have the common technical complication of delamination, or porcelain chipping, from the zirconia core. Thus the shear bond strength between the zirconia core and the veneering porcelain requires investigation in order to facilitate the material's clinical use. PURPOSE: The purpose of this study was to evaluate the bonding strength of the porcelain veneer to the zirconia core and to other various metal alloys (high noble metal alloy and base metal alloy). MATERIAL AND METHODS: 15 rectangular (4x4x9mm) specimens each of zirconia (Cercon), base metal alloy (Tillite), high noble metal alloy (Degudent H) were fabricated for the shear bond strength test. The veneering porcelain recommended by the manufacturer for each type of material was fired to the core in thickness of 3mm. After firing, the specimens were embedded in the PTFE mold, placed on a mounting jig, and subjected to shear force in a universal testing machine. Load was applied at a crosshead speed of 0.5mm/min until fracture. The average shear strength (MPa) was analyzed with the one-way ANOVA and the Tukey's test (alpha= .05). The fractured specimens were examined using SEM and EDX to determine the failure pattern. RESULTS: The mean shear strength (+/- SD) in MPa was 25.43 (+/- 3.12) in the zirconia group, 35.87 (+/- 4.23) in the base metal group, 38.00 (+/- 5.23) in the high noble metal group. The ANOVA showed a significant difference among groups, and the Tukey's test presented a significant difference between the zirconia group and the metal group. Microscopic examination showed that the failure primarily occurred near the interface with the residual veneering porcelain remaining on the core. CONCLUSION: There was a significant difference between the metal ceramic and zirconia ceramic group in shear bond strength. There was no significant difference between the base metal alloy and the high noble metal alloy.
Ceramics
;
Collodion
;
Dental Porcelain
;
Fires
;
Fungi
;
Polytetrafluoroethylene
;
Shear Strength
;
Zirconium
4.A comparative study on the accuracy of the devices for measuring the implant stability.
In Ho CHO ; Young Il LEE ; Young Mi KIM
The Journal of Advanced Prosthodontics 2009;1(3):124-128
STATEMENT OF PROBLEM: How the ISQ values measured by Osstell(TM) and Osstell(TM) Mentor are related, and whether the ISQ values acquired from the two machines changes in accordance with changes in implant stability are not yet fully understood. PURPOSE: The aim of this study was to find out correlation between the ISQ values acquired from Osstell(TM) and Osstell(TM) Mentor, and to evaluate the clinical effectiveness and accuracy of two devices. MATERIAL AND METHODS: Sixty two implants were inserted into 47 patients, and their ISQ values were measured using Osstell(TM) and Osstell(TM) Mentor. In the first stage surgery, the ISQ values of forty four implants inserted into thirty five patients were measured. In the second stage surgery, the values of fifty implants inserted into thirty seven patients were measured. The values were analyzed to determine the difference between the mean ISQ values of Osstell(TM) and Osstell(TM) Mentor. In addition, the correlation between implants used in the first and second stage of surgery with regard to their types and areas of insertion were analyzed. The difference between the ISQ values of 32 implants in each patient during the first and second stage was analyzed. The statistical assessment was carried out using SPSS V. 12.0 for Win. (SPSS Inc., Chicago, USA). The Pearson correlation coefficient was used to examine the correlation between Osstell(TM) and Osstell(TM) Mentor in the first and second stages of surgery, whereas the difference between their ISQ values was evaluated using a paired t-test. RESULTS: In the first stage, the mean ISQ value for Osstell(TM) and Osstell(TM) Mentor was 70.84 and 75.09, respectively, showing a significant difference (P < .01). In the second stage, the mean ISQ value of Osstell(TM) and Osstell(TM) Mentor was 71.76 and 75.94, respectively, also showing a significant difference (P < .01). The difference between the ISQ values in patients in the first and the second stages was significant with both instruments. CONCLUSION: The significant difference in the values obtained using the Osstell(TM) and Osstell(TM) Mentor between the first and second stages of implant surgery indicates that these values can be a convenient and precise way for evaluating the implant stability in clinical practice.
Chicago
;
Humans
;
Mentors
5.Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis.
Seok Gyu KIM ; Chae Heon CHUNG ; Mee Kyoung SON
The Journal of Advanced Prosthodontics 2015;7(3):207-213
PURPOSE: The purpose of this study was to examine the abutment screw stability of screw- and cement-retained implant-supported dental prosthesis (SCP) after simulated cement washout as well as the stability of SCP cements after complete loosening of abutment screws. MATERIALS AND METHODS: Thirty-six titanium CAD/CAM-made implant prostheses were fabricated on two implants placed in the resin models. Each prosthesis is a two-unit SCP: one screw-retained and the other cemented. After evaluating the passive fit of each prosthesis, all implant prostheses were randomly divided into 3 groups: screwed and cemented SCP (Control), screwed and noncemented SCP (Group 1), unscrewed and cemented SCP (Group 2). Each prosthesis in Control and Group 1 was screwed and/or cemented, and the preloading reverse torque value (RTV) was evaluated. SCP in Group 2 was screwed and cemented, and then unscrewed (RTV=0) after the cement was set. After cyclic loading was applied, the postloading RTV was measured. RTV loss and decementation ratios were calculated for statistical analysis. RESULTS: There was no significant difference in RTV loss ratio between Control and Group 1 (P=.16). No decemented prosthesis was found among Control and Group 2. CONCLUSION: Within the limits of this in vitro study, the stabilities of SCP abutment screws and cement were not significantly changed after simulated cement washout or screw loosening.
Dental Cements
;
Dental Prosthesis, Implant-Supported*
;
Prostheses and Implants
;
Titanium
;
Torque
6.Impact of surface roughness of gypsum materials on adaptation of zirconia cores.
Ki Baek KIM ; Jae Hong KIM ; Sa Hak KIM
The Journal of Advanced Prosthodontics 2015;7(3):199-206
PURPOSE: The present study investigated the influences of various gypsum materials on the precision of fit of CAD/CAM-fabricated prostheses and analyzed their correlation with surface roughness. MATERIALS AND METHODS: The master model of the mandibular right first molar was replicated, and four experimental groups based on two types of Type IV stone (GC Fujirock EP, Die keen) and two types of scannable stone (Aesthetic-Basegold, Everest Rock) were created to include a total of 40 specimens, 10 in each group. The surface roughness of the working models for the respective experimental groups was measured. Once the zirconia cores had been fabricated, the marginal and internal fits were measured with a digital microscope using the silicone replica technique. The mean and standard deviation of the respective points of measurement were computed and analyzed through the one-way ANOVA and Tukey's HSD test. The correlation between surface roughness and the precision of fit of the zirconia core was analyzed using the Pearson correlation analysis (alpha=.05). RESULTS: The zirconia cores fabricated from the scannable stone working models exhibited a superior precision of fit as compared to those fabricated from the Type IV stone working models. The correlation analysis results showed a clear positive correlation between surface roughness and the precision of fit of zirconia cores in all of the experimental groups (P<.05). CONCLUSION: The results confirmed that the surface roughness of dental working models has a decisive influence on the precision of fit of zirconia cores.
Calcium Sulfate*
;
Molar
;
Prostheses and Implants
;
Replica Techniques
;
Silicones
7.Comparison of marginal bone loss and patient satisfaction in single and double-implant assisted mandibular overdenture by immediate loading.
Sara TAVAKOLIZADEH ; Fariborz VAFAEE ; Masume KHOSHHAL ; Zahra EBRAHIMZADEH
The Journal of Advanced Prosthodontics 2015;7(3):191-198
PURPOSE: The purpose of this study was to compare the coronal bone level and patient satisfaction in 1-implant and 2-implant assisted mandibular overdentures. MATERIALS AND METHODS: Twenty patients who had maladaptive mandibular dentures were treated in this study. Patients were randomly divided into two groups. The first group received 1 implant (Simple line II, Implantium, South Korea) in their mandibular midline and the second group received 2 implants in their B and D regions (according to Misch's category). If the primary stability of each implant was at least 60 ISQ, ball attachment was placed and denture relined with soft liner. After 6 weeks, retentive cap incorporated with hard acrylic resin. In the 6 and 12 months recalls, periapical digital radiograph were made and visual analogue scale questionnaires were used to record patient satisfaction. The Friedman test was done for comparing the presurgical and postsurgical parameters in each group and the U-Mann Whitney test (P<.05) was done for comparison of post-treatment results between the two groups. RESULTS: All implants achieved sufficient primary stability to be immediately loaded. Patient satisfaction was high, and there were no significant differences between two groups (P>.05). In addition, mean marginal bone loss was 0.6 +/- 0.67 mm in the first group and 0.6 +/- 0.51 mm in the second group, after 12 month. Mean marginal bone loss showed no significant differences between two groups. CONCLUSION: This preliminary one-year result indicated that mandibular overdentures anchored to a single implant can be a safe and cost-effective method as a starting step for implant-overdenture treatment.
Denture, Overlay*
;
Dentures
;
Humans
;
Patient Satisfaction*
;
Surveys and Questionnaires
8.Influence of preparation depths on the fracture load of customized zirconia abutments with titanium insert.
Han Sung JOO ; Hong So YANG ; Sang Won PARK ; Hyun Seung KIM ; Kwi Dug YUN ; Min Kyung JI ; Hyun Pil LIM
The Journal of Advanced Prosthodontics 2015;7(3):183-190
PURPOSE: This study evaluated the fracture load of customized zirconia abutments with titanium insert according to preparation depths, with or without 5-year artificial aging. MATERIALS AND METHODS: Thirty-six identical lithium disilicate crowns (IPS e.max press) were fabricated to replace a maxillary right central incisor and cemented to the customized zirconia abutment with titanium insert on a 4.5x10 mm titanium fixture. Abutments were fabricated with 3 preparation depths (0.5 mm, 0.7 mm, and 0.9 mm). Half of the samples were then processed using thermocycling (temperature: 5-55degrees C, dwelling time: 120s) and chewing simulation (1,200,000 cycles, 49 N load). All specimens were classified into 6 groups depending on the preparation depth and artificial aging (non-artificial aging groups: N5, N7, N9; artificial aging groups: A5, A7, A9). Static load was applied at 135 degrees to the implant axis in a universal testing machine. Statistical analyses of the results were performed using 1-way ANOVA, 2-way ANOVA, independent t-test and multiple linear regression. RESULTS: The fracture loads were 539.28 +/- 63.11 N (N5), 406.56 +/- 28.94 N (N7), 366.66 +/- 30.19 N (N9), 392.61 +/- 50.57 N (A5), 317.94 +/- 30.05 N (A7), and 292.74 +/- 37.15 N (A9). The fracture load of group N5 was significantly higher than those of group N7 and N9 (P<.017). Consequently, the fracture load of group A5 was also significantly higher than those of group A7 and A9 (P<.05). After artificial aging, the fracture load was significantly decreased in all groups with various preparation depths (P<.05). CONCLUSION: The fracture load of a single anterior implant restored with lithium disilicate crown on zirconia abutment with titanium insert differed depending on the preparation depths. After 5-year artificial aging, the fracture loads of all preparation groups decreased significantly.
Aging
;
Axis, Cervical Vertebra
;
Crowns
;
Dental Implants
;
Incisor
;
Linear Models
;
Lithium
;
Mastication
;
Titanium*
9.Rehabilitation of a patient with non-syndromic partial oligodontia.
Hyeon Goo KANG ; Yoon Hyuk HUH ; Chan Jin PARK ; Lee Ra CHO
The Journal of Advanced Prosthodontics 2016;8(3):241-250
Oligodontia is defined as a congenital tooth agenesis with the absence of six or more permanent teeth. This clinical report describes a patient with non-syndromic partial oligodontia, with retained deciduous teeth and the absence of 16 permanent teeth. Anterior esthetic problems were caused by interarch tooth size discrepancy, interdental space, aberrant tooth dimensions, and the absence of centric contacts of the anterior teeth. Prosthetic restoration after orthodontic and implant treatment was performed with a multi-disciplinary team approach. Favorable functional and esthetic results were obtained using a definitive prosthesis.
Humans
;
Prostheses and Implants
;
Rehabilitation*
;
Tooth
;
Tooth, Deciduous
10.Comparison of alkaline phosphatase activity of MC3T3-E1 cells cultured on different Ti surfaces: modified sandblasted with large grit and acid-etched (MSLA), laser-treated, and laser and acid-treated Ti surfaces.
Lin Jie LI ; So Nam KIM ; Sung Am CHO
The Journal of Advanced Prosthodontics 2016;8(3):235-240
PURPOSE: In this study, the aim of this study was to evaluate the effect of implant surface treatment on cell differentiation of osteoblast cells. For this purpose, three surfaces were compared: (1) a modified SLA (MSLA: sand-blasted with large grit, acid-etched, and immersed in 0.9% NaCl), (2) a laser treatment (LT: laser treatment) titanium surface and (3) a laser and acid-treated (LAT: laser treatment, acid-etched) titanium surface. MATERIALS AND METHODS: The MSLA surfaces were considered as the control group, and LT and LAT surfaces as test groups. Alkaline phosphatase expression (ALP) was used to quantify osteoblastic differentiation of MC3T3-E1 cell. Surface roughness was evaluated by a contact profilometer (URFPAK-SV; Mitutoyo, Kawasaki, Japan) and characterized by two parameters: mean roughness (Ra) and maximum peak-to-valley height (Rt). RESULTS: Scanning electron microscope revealed that MSLA (control group) surface was not as rough as LT, LAT surface (test groups). Alkaline phosphatase expression, the measure of osteoblastic differentiation, and total ALP expression by surface-adherent cells were found to be highest at 21 days for all three surfaces tested (P<.05). Furthermore, ALP expression levels of MSLA and LAT surfaces were significantly higher than expression levels of LT surface-adherent cells at 7, 14, and 21 days, respectively (P<.05). However, ALP expression levels between MSLA and LAT surface were equal at 7, 14, and 21 days (P>.05). CONCLUSION: This study suggested that MSLA and LAT surfaces exhibited more favorable environment for osteoblast differentiation when compared with LT surface, the results that are important for implant surface modification studies.
Alkaline Phosphatase*
;
Cell Differentiation
;
Osteoblasts
;
Titanium