1.Three cases of troubleshooting for Bird-brand ventilator
China Medical Equipment 2009;(8):54-55
Ventilator is broadly used in the hospital all over the world,The paper describes three case of common troubles in clinical practice for Bird-brand ventilator and its troubleshooting.
2.Property and Effect in Chinese Ancient Herbalism
Journal of Traditional Chinese Medicine 2017;58(17):1447-1449,1461
The construction of traditional theory of Chinese herbalism cannot do without the accumulated understanding of herb effect in clinical practice.Meanwhile,it closely relates to the natural history of using different theories of herb property to explain effect and mechanism at different stages.The compilation of Inner Canon of Yellow Emperor 《(黄帝内经》) and Shennong Bencao Jing 《神农本草经》) represent the initial formation of traditional herbalism in Chinese medicine.These two books have a relatively complete description of property and effects of herbs,but with different focus of concerning.After Shennong Bencao Jing,explaining the effect from property of herbs gradually become the developing trend and basic characteristics of herbalism.During the Ming-Qing Dynasties,publication of a large number of herbal annotation works further highlights this feature.
3.Construction and self-activation detection of yeast two-hybrid bait plasmid of human programmed cell death ligand 1 immunoglobulin variable region domain gene
Chinese Journal of Biologicals 2024;37(1):8-16
Objective To construct a yeast two-hybrid recombinant bait plasmid of human programmed cell death ligand 1(PD-L1)immunoglobulin variable region(IgV)domain gene,detect its expression in yeast and detect the cytotoxicity and self-activation of PD-L1 IgV protein as well as the interaction between PD-L1 IgV and human thioredoxin(hTrx).Methods Human PD-L1 was analyzed by bioinformatics method,and primers were designed to amplify PD-L1 IgV domain based on the coding region of PD-L1 gene registered in NCBI GenBank database. PCR amplification was carried out with pENTERPD-L1 plasmid as template,and then cloned into yeast two-hybrid bait vector pGBKT7. The recombinant bait plasmid and pGBKT7 empty vector were transformed into Y2HGold yeast cells respectively,and the PD-L1 IgV gene and its expression were detected by PCR and Western blot;Meanwhile,the protein toxicity and self-activation of PD-L1 IgV were detected,and the interaction between PD-L1 IgV and hTrx was detected by drip plate method.Results The bioinformatics analysis results of PD-L1 were consistent with related reports. The recombinant bait plasmid pGBKT7-PD-L1 IgV was correctly constructed,and Y2HGold positive clone was obtained,in which PD-L1 IgV was stably expressed. The empty vector pGBKT7 and recombinant bait plasmid pGBKT7-PD-L1 IgV grew well on SD/-Trp and SD/-Trp/X-α-Gal plates with the same colony size and number and white colony,but they did not grow on SD/-Trp/X-α-Gal/AbA plates,which indicated that PD-L1 IgV protein had no toxicity and no self-activation effect on yeast. The results of drip plates test showed that all experimental groups grew well on SD/-Trp/-Leu plate,while only positive control group grew on SD/-Trp/-Leu/X-α-Gal/AbA plate and showed blue color,which indicated that bait protein PD-L1 IgV and hTrx did not self-activate,and there was no interaction between them.Conclusion Recombinant human PD-L1 IgV bait plasmid was successfully constructed. PD-L1 IgV protein showed no toxicity and self-activation effect on yeast cells,and there was no interaction between PD-L1 IgV and hTrx. Subsequently,hTrx can be used to construct a peptide aptamer library,from which peptide aptamers that specifically bind to PD-L1 IgV can be screened.
4.A comparison of computer-assisted total knee arthroplasty through vastus medialis approach and conventional arthroplasty
Chinese Journal of Tissue Engineering Research 2016;20(22):3205-3211
BACKGROUND:In the treatment of primary knee osteoarthritis, total knee arthroplasty is a common treatment, but there are some shortcomings in the traditional operation, which maylead to early failure of the prosthesis.
OBJECTIVE:To explore the difference of computer-assisted total knee arthroplasty by vastus medialis approach from the traditional total knee arthroplasty.
METHODS:A total of 79 patients with primary knee osteoarthritis were randomly divided into control group (41 cases) and observation group (38 cases), which underwent conventional total knee arthroplasty and computer-assisted total knee arthroplasty by vastus medialis approach. Surgical incision, operation time, total blood loss and drainage volume were recorded and compared in both groups. In 12 months of folow-up, Hospital for Special Surgery knee score was evaluated, and the complications were recorded and compared between the two groups.
RESULTS AND CONCLUSION:(1) Operative incision was significantly less in the observation group than in the control group. Operation time was significantly shorter in the observation group than in the control group. Total blood loss and drainage volume were significantly lessin the observation group than in the control group (alP< 0.05). (2) Patients in both groups were folowed up for 12 months. Index score and total score of knee function were significantly higher in the observation group than in the control group (al P< 0.05). (3) No adverse events such as infection, prosthesis loosening or fracture appeared in the observation group. In the control group, four cases affected prosthesis loosening. One case suffered from wound infection. Above events were improved obviously after active treatment. No serious complications occurred. The incidence of complications was significantly lower in the observation group than in the control group (P< 0.05). (4) The results show that, compared with the traditional operation, the choice of the femoral medial approach and the use of computer aided design technology can simulate the knee replacement process, set the cutting position, improve the accuracy and success rate of surgery, have less trauma, and effectively improve knee function, and reduce the incidence of postoperative complications.
5.Software version and medical device software supervision.
Chinese Journal of Medical Instrumentation 2015;39(1):48-50
The importance of software version in the medical device software supervision does not cause enough attention at present. First of all, the effect of software version in the medical device software supervision is discussed, and then the necessity of software version in the medical device software supervision is analyzed based on the discussion of the misunderstanding of software version. Finally the concrete suggestions on software version naming rules, software version supervision for the software in medical devices, and software version supervision scheme are proposed.
Equipment and Supplies
;
Software
6. Determination of pantoprazole in human plasma by LC-MS/MS
Chinese Pharmaceutical Journal 2013;48(8):633-635
OBJECTIVE: To determine the concentration of pantoprazole in human plasma and evaluate the bioequivalence of two kinds of pantoprazole sodium enteric-coated tablets. METHODS: The concentration of pantoprazole in human plasma was determined by LC-MS/MS, and the pharmacokinetic parameters for evaluation of bioequivalence were calculated with DAS2.0. RESULTS: The main pharmacokinetic parameters of test and reference formulation were as follows; t1/2 (1.96±0.66) and (1.98±0.59) h, (3.17±0.84) and (3.09±0.81) h, pmax(3.53±0.78) and (3.41±0.79) μg · mL-1, AUC0-∞ (10.12±4.09) and (10.86±3.99) μg · h · mL-1. The relative bioavailability was (97.9±22.3)%. CONCLUSION: The method is repeatable and sensitive. The test and reference formulation are bioequivalent.
7.Inhibition of autoimmune diabetes in NOD mice by GAD-specific regulatory T cells
Chinese Journal of Endocrinology and Metabolism 2000;0(06):-
Objective To investigate the role of antigen-specific regulatory T cells in spontaneous diabetes of NOD mice. Methods Glutamic acid decarboxylase (GAD)-peptide specific T cells with fluorescein-labelled Class Ⅱ MHC tetramers were isolated by flow cytometer from NOD mice with spontaneous diabetes and diabetes resistant BALB/c mice. The cytokine profiles of these T cells were detected by antigen stimulated assay, ELISA and intracellular cytokine staining. Adoptively transferred diabetes was determined by intravenously injecting these T cells to NOD/scid mice. Results With different peptides working on the same strain, it showed that NOD mice-derived T cells secreted different amounts of interforn-? but comparable interlenkin (IL)-4 or IL-10, however, similar cytokine profiles were shown in BALB/c mice-derived T cells. With the same peptide working on different strains, NOD mice-derived T cells secreted less IL-2 but more IL-4 and IL-10 than BALB/c mice-derived T cells did. Interestingly, these NOD mice-derived T cells effectively inhibited diabetes development in adoptively transferred NOD/scid mice. Conclusion NOD mice-derived T cells inhibit development of diabetes, however, different cytokine profiles are expressed by these T cells induced by two adjacent GAD peptides. It suggests that these T cells are diabetes-inhibiting regulatory T cells displaying unique cytokine profiles.
8.Effect of a layered nursing intervention based on risk assessment strategies application in elderly patients with hip replacement
Chinese Journal of Practical Nursing 2017;33(9):669-672
Objective To explore a layered nursing intervention based on risk assessment strategies application effect in elderly patients with hip replacement. Methods Chosen during January 2013 to December 2014 rows of orthopaedic trauma treated 224 patients of senile hip replacement as the research objectto divide into observation group and control group 112 caseseach according to admission time.Observation group applied based on risk assessment strategy stratification nursing intervention, the control group used conventional care. Compared two groups of patients with postoperative pain degree, hip function, complications, and patient satisfaction. Results For 24 h, 48 h, 72 h after the operation, Visual Analog Scale (VAS) scores of observation groupwere 2.25 ± 0.35, 2.01 ± 0.31, 1.92 ± 0.23, which were significantly lower than 3.53 ± 0.51, 2.84±0.45, 2.70±0.35 of the control group (t=21.900, 16.075, 21.900, P<0.01);3 months and 12 months after the surgery, the index of the Harris hip score observation group was 71.32 ± 7.45, 93.44 ± 9.65, which were obviously higher than 60.47 ± 6.65, 83.75 ± 9.21 of control group (t=11.498, 7.688, P<0.01);8.04%(9/112) incidence of complications such as infection of incision, increase of observation group was obviously lower than 20.54%(23/112) of the control group(χ2=7.146, P<0.05);97.32%(109/112) satisfaction was significantly higher than 78.57% (88/112) of the control group (χ2= 18.572, P < 0.05). Conclusions Stratified nursing intervention based on risk assessment strategy can help to alleviate the degreeof pain, improve hip function, reduce postoperative complications and improve patient satisfaction.
9.Analysis of the Antivirals Used in 136 Hospitals of 6 Cities in the Yangtse Valley of China
China Pharmacy 2001;0(11):-
OBJECTIVE:To survey and objectively evaluate the present situation and trend of the usages of the antivirals METHODS:To make a survey of the usage for above-mentioned drugs in 136 hospitals of 6 cities in the Yangtse valley of China during the period 1998~2000 concerning the sum of money for drugs,main pharmaceutical enterprises etc and to analyse the situation of clinical use and trend forecast RESULTS:The sum of money for the antivirals was 17 330 331 yuans,24 068 239 yuans and 47 427 419 yuans in 1998,in 1999 and in 2000,respectively Total expenditure and consumption for the antivirals in China increased year by year CONCLUSION:The antivirals is a kind of drug which has developmental potential,the expenditure and consumption will increase rapidly
10.Effect of Several Cleaning Methods on Laparoscope
Chinese Journal of Nosocomiology 2005;0(11):-
OBJECTIVE To compare the cleaning efficacy of manual cleaning with ultrasonic cleaning on laparoscope and choose the best way to clean laparoscope under present condition.METHODS The laparoscopes were collected from each department based on the weekly usages.The efficacy of the cleaning way was the focus.The cleaniness of the laparoscopes were inspected with naked eyes.RESULTS The cleaning effect of the ultrasonic cleaning method was better than the manual cleaning method for the laparoscope.It would help for the cleaning effect to remove the air bubble in the laparoscope pipeline.CONCLUSIONS Ultrasonic cleaning method plus removing the air bubble in the laparoscope pipeline could guarantee the cleaning quality for the laparoscope.