1.Early effectiveness of a new minimally invasive plate in treatment of varus-type ankle arthritis.
Xuewen WANG ; Heng LI ; Xiaofeng GONG ; Liangpeng LAI ; Wenjing LI ; Yan WANG ; Hui DU ; Ying LI ; Ning SUN ; Yong WU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(7):776-781
OBJECTIVE:
To evaluate the early effectiveness of a new minimally invasive plate in the treatment of varus-type ankle arthritis.
METHODS:
A clinical data of 15 patients with varus-type ankle arthritis who met the selection criteria between March 2021 and October 2021 were retrospectively analyzed. All the patients were treated with medial open-wedge supramalleolar osteotomy and fibular osteotomy. The osteotomies were fixed with the new minimally invasive plate. There were 7 males and 8 females with an average age of 49.8 years (range, 16-71 years). The causes of ankle arthritis included post-fracture deformity in 1 case, sprain in 8 cases, and acquired clubfoot in 1 case; and 5 cases were without obvious factors. The disease duration ranged from 1 to 12 years, with an average of 4.1 years. Comparisons were made between pre-operation and the last follow-up in the Takakura staging, the American Orthopedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, foot function index (FFI), visual analogue scale (VAS) score, tibial anterior surface angle (TAS), tibial lateral surface angle (TLS), and talar tilt (TT).
RESULTS:
All incisions healed by first intention. All patients were followed up 7-18 months (mean, 12.8 months). At last follow-up, the AOFAS ankle-hindfoot score, FFI, VAS score, and Takakura staging significantly improved when compared with the preoperative ones ( P<0.05). X-ray films showed that the osteotomy healed at 3 months after operation. At last follow-up, TAS significantly increased and TT decreased when compared with the preoperative ones ( P<0.05), and the difference in TLS between pre- and post-operation was not significant ( P>0.05). Complications included 1 case of intraoperative screw breakage and 2 cases of nerve injury of the affected foot. None of the patients complained of significant discomfort at the plate placement during follow-up, and no loosening of the internal fixator occurred. Eleven patients were very satisfied with the effeectiveness, while 4 were relatively satisfied.
CONCLUSION
The new minimally invasive plate for the varus-type ankle arthritis has good early effectiveness in relieving ankle pain, correcting deformity, improving limb alignment and ankle function, and reducing the incidence of postoperative incisional complications.
Female
;
Humans
;
Male
;
Middle Aged
;
Ankle
;
Ankle Joint/surgery*
;
Osteoarthritis/surgery*
;
Retrospective Studies
;
Tibia/surgery*
;
Treatment Outcome
;
Adolescent
;
Young Adult
;
Adult
;
Aged
2.Establishment of finite element model of varus-type ankle arthritis and biomechanical analysis of different correction models for tibial anterior surface angle.
Cheng CHEN ; Yunfeng YANG ; Bing LI ; Jiang XIA ; Youguang ZHAO ; Hui ZHU ; Haichao ZHOU ; Yongqi LI ; Zhendong LI ; Wenbao HE ; Yi ZHANG ; Hui HUANG
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(7):796-801
OBJECTIVE:
To establish the finite element model of varus-type ankle arthritis and to implement the finite element mechanical analysis of different correction models for tibial anterior surface angle (TAS) in supramalleolar osteotomy.
METHODS:
A female patient with left varus-type ankle arthritis (Takakura stage Ⅱ, TAS 78°) was taken as the study object. Based on the CT data, the three-dimensional model of varus-type ankle arthritis (TAS 78°) and different TAS correction models [normal (TAS 89°), 5° valgus (TAS 94°), and 10° valgus (TAS 99°)] were created by software Mimics 21.0, Geomagic Wrap 2021, Solidworks 2017, and Workbench 17.0. The 290 N vertical downward force was applied to the upper surface of the tibia and 60 N vertical downward force to the upper surface of the fibula. Von Mises stress distribution and stress peak were calculated.
RESULTS:
The finite element model of normal TAS was basically consistent with biomechanics of the foot. According to biomechanical analysis, the maximum stress of the varus model appeared in the medial tibiotalar joint surface and the medial part of the top tibiotalar joint surface. The stress distribution of talofibular joint surface and the lateral part of the top tibiotalar joint surface were uniform. In the normal model, the stress distributions of the talofibular joint surface and the tibiotalar joint surface were uniform, and no obvious stress concentration was observed. The maximum stress in the 5° valgus model appeared at the posterior part of the talofibular joint surface and the lateral part of the top tibiotalar joint surface. The stress distribution of medial tibiotalar joint surface was uniform. The maximum stress of the 10° valgus model appeared at the posterior part of the talofibular joint surface and the lateral part of the top tibiotalar joint surface. The stress on the medial tibiotalar joint surface increased.
CONCLUSION
With the increase of valgus, the stress of ankle joint gradually shift outwards, and the stress concentration tends to appear. There was no obvious obstruction of fibula with 10° TAS correction. However, when TAS correction exceeds 10° and continues to increase, the obstruction effect of fibula becomes increasingly significant.
Humans
;
Female
;
Tibia/surgery*
;
Finite Element Analysis
;
Ankle
;
Arthritis
;
Fibula/surgery*
;
Ankle Joint/surgery*
3.Correction of tibial multiplanar deformities using single Taylor external fixator combined with biplanar osteotomy.
Shaofeng JIAO ; Sihe QIN ; Zhenjun WANG ; Yue GUO ; Hongsheng XU ; Zhijie LIU ; Jianwen CHEN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(7):839-845
OBJECTIVE:
To investigate the effectiveness of single Taylor external fixator combined with biplanar osteotomy on correction of tibial multiplanar deformities.
METHODS:
Between October 2016 and December 2021, 11 patients with tibial multiplanar deformities (20 sides) were treated with single Taylor external fixator and biplanar osteotomy. Of them, 4 were male and 7 were female; the average age ranged from 13 to 33 years (mean, 21.9 years). Diagnosis included rickets severe genu varum deformity (7 cases, 14 sides), rickets severe genu valgum deformity (2 cases, 4 sides), multiple osteochondromatosis calf deformity (1 case, 1 side), neurofibromatosis medial lower leg anterior arch deformity with short of leg (1 case, 1 side). After fibular osteotomy and tibial multiplanar osteotomy, a Taylor external fixator was installed. After operation, the deformities were corrected successively and fixed completely. The osteotomy healed, then the external fixator was removed. Before operation and at 12 months after operation, the full-length X-ray films were taken. The leg-length discrepancy, medial proximal tibial angle (MPTA), lateral distal tibial angle (LDTA), posterior proximal tibial angle (PPTA), anterior distal tibial angle (ADTA), and tibial rotation angle were measured. The degree of lower limb deformity was scored with reference to a customized tibial mechanical axis scoring table.
RESULTS:
Osteotomy was successfully completed without neurovascular injury and other complications. The external fixator was adjusted for 28-46 days, with an average of 37 days, and the external fixator was worn for 136-292 days, with an average of 169 days. Mild needle infection during the fixation period occurred in 3 sides, refracture at the distal tibial osteotomy in 1 side after removing the external fixator, and nonunion of the distal fibular osteotomy in 1 side. All patients were followed up 369-397 days (mean, 375 days). At 12 months after operation, the lower limb discrepancy decreased, but there was no significant difference ( P>0.05). MPTA, LDTA, PPTA, ADTA, and tibial rotation angle improved, and the differences in LDTA, ADTA, and tibial rotation angle were significant ( P<0.05). The score of lower limb deformity was significantly higher than that before operation ( P<0.05), and the results were excellent in 9 sides, good in 8 sides, fair in 3 sides, with the excellent and good rate of 85%.
CONCLUSION
Single Taylor external fixator combined with biplanar osteotomy is effective in the correction of tibial multiplanar deformities.
Humans
;
Male
;
Female
;
Adolescent
;
Young Adult
;
Adult
;
Tibia/surgery*
;
Osteotomy/methods*
;
Rickets
;
External Fixators
;
Retrospective Studies
;
Treatment Outcome
4.A study on repair method of type Ⅱc injury in lateral meniscus popliteal tendon area of porcine knee.
He WU ; Zhu DAI ; Yuxi CHEN ; Weijie FAN ; Ying LIAO ; Chao LIU ; Jianghua LIU
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(7):856-861
OBJECTIVE:
To investigate the repair method of type Ⅱc injury in the lateral meniscus popliteal tendon area based on the porcine knee joint.
METHODS:
Eighteen commercially available fresh porcine knee joints were randomly divided into 3 groups ( n=6). After preparing a type Ⅱc injury in the lateral meniscus popliteal tendon area, and the anterior (group A), posterior (group B), or anterior and posterior (group C) of the popliteal hiatus (PH) was sutured by vertical mattress. The tension meter was used to apply gradient tensions of 2, 4, 6, 8, and 10 N along the tibial plateau horizontally, respectively, to pull the midpoint of the lateral meniscus popliteal tendon area. The displacement values before modeling, after modeling, and after suture were recorded. The reduction value of lateral meniscus displacement and reduction rate after suture were calculated and compared between groups.
RESULTS:
There was no significant difference between groups ( P>0.05) in the displacement values before modeling, after modeling, and after suture under different tensions. There was no significant difference between groups A and C ( P>0.05) in the reduction value of lateral meniscus displacement and reduction rate after suture under different tensions. The reduction value of lateral meniscus displacement and reduction rate after suture in group B were lower than those in groups A and C. The reduction value of lateral meniscus displacement under tension of 2 N and the reduction rates under tensions of 2, 4, and 6 N between groups A and B showed significant differences ( P<0.05). The reduction value of lateral meniscus displacement and the reduction rate under tensions of 2, 4, and 6 N between groups B and C showed significant differences ( P<0.05).
CONCLUSION
Suturing the anterior area of PH is the key to repairing type Ⅱc injury of lateral meniscus popliteal tendon area.
Animals
;
Humans
;
Knee
;
Knee Joint
;
Menisci, Tibial/surgery*
;
Swine
;
Tendons
;
Tibia
5.Correlation analysis between imaging classification of varus knee osteoarthritis and axis angle of tibiofemoral and patellofemoral joints.
Xiao YU ; Yong MA ; Yang GUO ; Ling WANG ; Zhen GONG ; Li-Jia HUANG
China Journal of Orthopaedics and Traumatology 2023;36(4):364-370
OBJECTIVE:
To explore correlation between imaging classification of knee osteoarthritis (KOA) and axis angle of tibiofemoral and patellofemoral joints.
METHODS:
A retrospective analysis of 739 middle-aged and elderly patients with KOA (1 026 knee joints) who underwent vertical X-ray examination of both lower limbs and lateral knee joints from September 2018 to December 2020. Among them, 63 patients with K-L 0 grade (95 knee joints), 100 patients with K-L 1 grade (130 knee joints), 161 patients with K-L 2 grade (226 knee joints), 187 patients with K-L 3 grade (256 knee joints), and 228 patients of K-L 4 grade (319 knee joints). According to relative position of knee joint center and line between hip joint center and ankle joint center, the affected knee was divided into varus group(844 knees joints) and valgus group (182 knees joints). According to Install-Salvati method, the affected knee was divided into three groups, such as high patella (patella height>1.2 mm, 347 knees joints), median patella (patella height ranged from 0.8 to 1.2 mm, 561 knees joints), and low patella (patella height<0.8 mm, 118 knees joints). Lower femur angle, upper tibia angle, femoral neck shaft angle, femoral tibial angle, joint gap angle, hip-knee-ankle angle, patella-femoral angle and patella height among different groups were observed and compared.
RESULTS:
(1) In varus KOA group, there were statistical differnces in hip-knee-ankle angle, tibiofemoral angle, lower femoral angle, upper tibial angle, joint space angle, and femoral neck shaft angle of patients with different K-L grades (P<0.05). Hip-knee-ankle angle, tibiofemoral angle, lower femoral angle, upper tibial angle, joint space angle and K-L grade were significantly positively correlated at 0.01(P<0.05);femoral neck shaft angle and K-L grade showed negative correlation at 0.01(P<0.05). (2) In valgus KOA group, hip-knee-ankle angle, there were statistical differences in tibiofemoral angle, inferior femoral angle, superior tibial angle, joint space angle, and femoral neck shaft angle of patients with different K-L grades(P<0.05). Hip-knee-ankle angle, tibiofemoral angle, lower femoral angle, upper tibial angle, and femoral neck shaft angle showed negative correlation with K-L grades at level of 0.01 (P<0.05);joint gap angle and K-L grades showed significantly positive correlation at level of 0.01(P<0.05). (3) In high patella group, there were statistically differences in patellar height and patellar femoral angle of different K-L grades(P<0.05);there were no statistical difference in patella height and patellar femoral angle of different K-L grades in median patella group. There was no significant difference in patella heightin low patella group with different K-L grades(P>0.05), and there was statistical difference in patellofemoral angle(P<0.05). Patellar height and patella-femoral angle of high patella group were significantly positively correlated with K-L grades at the level of 0.01 (P<0.05);patella height and patella-femoral angle were not correlated with K-L grades in median patella group(P>0.05). There was no correlation between height of patella and K-L grade in low patella group (P>0.05). There was significant negative correlation between patella-femoral angle and K-L grade at level of 0.05 (P<0.05).
CONCLUSION
Inferior femoral angle, tibiofemoral angle, joint gap angle, hip-knee-ankle angle, femoral neck shaft angle and high patella are related to K-L classification of varus KOA, which could be used for early diagnosis and provide objective data for efficacy analysis of conservative treatment.
Aged
;
Middle Aged
;
Humans
;
Patellofemoral Joint/diagnostic imaging*
;
Osteoarthritis, Knee/diagnostic imaging*
;
Retrospective Studies
;
Knee Joint
;
Femur/diagnostic imaging*
;
Tibia
6.Value of personalized osteotomy in primary total knee arthroplasty for severe varus knee osteoarthritis.
Ying-Jie YAN ; Gang JIA ; Ding-Wen BAI
China Journal of Orthopaedics and Traumatology 2023;36(4):386-392
OBJECTIVE:
To explore application value and efficacy of personalized osteotomy in primary total knee arthroplasty (TKA) for severe varus knee osteoarthritis.
METHODS:
From June 2018 to January 2020, 36 patients (49 knees) with severe varus knee osteoarthritis were treated, including 15 males (21 knees) and 21 females (28 knees), aged from 59 to 82 years old with an average of (67.6 ± 6.5) years old;the course of disease ranged from 9.5 to 20.5 years with an average of (15.0 ± 5.0) years;11 patients (15 knees) with Kellgren-Lawrence grade Ⅲ and 25 patients (34 knees) with grade Ⅳ according to Kellgren-Lawrence grading. According to AORI clsssification of tibial bone defects, 8 patients (15 knees) were typeⅠTa and 16 patients (18 knees) were typeⅡ T2a. All patients' femor-tibial angle (FTA) was above 15°, and received primary TKA with personalized osteotomy. Thirty-three patients (45 knees) were treated with posterior-stabilized (PS) prostheses, 13 patients (15 knees) with PS prostheses combined with a metal pad and extension rod on the tibial side, and 3 patients (4 knees) with legacy constrained condylar knee (LCCK) prostheses. FTA, posterior condylar angle (PCA), medial proximal tibial angle (MPTA) and lateral distal femoral angle (LDFA) before and after operation at 1 month were measured and compared by using picture archiving and communication systems (PACS). Recovery of lower limbs before and after operation at 12 months was evaluated by American Knee Society Score(KSS), and complications were observed and recorded.
RESULTS:
All 36 patients (49 knees) were followed up from 15 to 40 months with an average of (23.46±7.65) months. FTA, MPTA were corrected from preoperative (18.65±4.28)° and (83.75±3.65)° to postoperative (2.35±1.46)° and (88.85±2.25)° at 1 month, respectively (P<0.001). PCA was decreased from (2.42±2.16)° before operation to (1.65±1.35)° at 1 month after operation, LDFA improved from (89.56 ± 3.55)° before operation to (91.63±3.38)° at 1 month after operation (P<0.05). KSS increased from (67.58±24.16) before opertion to(171.31±15.24) at 12 months after operation, 14 patients (19 knees) got excellent result, 19 (26 knees) good, and 3 (4 knees) fair.
CONCLUSION
Personalized osteotomy is helpful for recovery of axial alignment of lower limbs and correct placement of prosthesis, could effectively relieve pain of knee joint, recover knee joint function.
Male
;
Female
;
Humans
;
Child
;
Adolescent
;
Young Adult
;
Adult
;
Arthroplasty, Replacement, Knee
;
Osteoarthritis, Knee/surgery*
;
Retrospective Studies
;
Knee Joint/surgery*
;
Osteotomy
;
Tibia/surgery*
8.Effect of prosthetic joint line installation height errors on insert wear in unicompartmental knee arthroplasty.
Shoulin XIONG ; Yafei QU ; Jiaxuan REN ; Jing ZHANG ; Hui LI ; Zhenxian CHEN
Journal of Biomedical Engineering 2023;40(6):1192-1199
The clinical performance and failure issues are significantly influenced by prosthetic malposition in unicompartmental knee arthroplasty (UKA). Uncertainty exists about the impact of the prosthetic joint line height in UKA on tibial insert wear. In this study, we combined the UKA musculoskeletal multibody dynamics model, finite element model and wear model to investigate the effects of seven joint line height cases of fixed UKA implant on postoperative insert contact mechanics, cumulative sliding distance, linear wear depth and volumetric wear. As the elevation of the joint line height in UKA, the medial contact force and the joint anterior-posterior translation during swing phase were increased, and further the maximum von Mises stress, contact stress, linear wear depth, cumulative sliding distance, and the volumetric wear also were increased. Furthermore, the wear area of the insert gradually shifted from the middle region to the rear. Compared to 0 mm joint line height, the maximum linear wear depth and volumetric wear were decreased by 7.9% and 6.8% at -2 mm joint line height, and by 23.7% and 20.6% at -6 mm joint line height, the maximum linear wear depth and volumetric wear increased by 10.7% and 5.9% at +2 mm joint line height, and by 24.1% and 35.7% at +6 mm joint line height, respectively. UKA prosthetic joint line installation errors can significantly affect the wear life of the polyethylene inserted articular surfaces. Therefore, it is conservatively recommended that clinicians limit intraoperative UKA joint line height errors to -2-+2 mm.
Humans
;
Arthroplasty, Replacement, Knee
;
Knee Joint
;
Knee Prosthesis
;
Mechanical Phenomena
;
Polyethylene
;
Osteoarthritis, Knee/surgery*
;
Tibia/surgery*
;
Biomechanical Phenomena
9.Research progress of tibial-graft fixation methods on anterior cruciate ligament reconstruction.
Dengjun YANG ; Fuke WANG ; Qiai ZHANG ; Yaozhang ZHANG ; Haopeng SHENTU ; Fan WANG
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(9):1162-1168
OBJECTIVE:
To review the studies about the tibial-graft fixation methods on anterior cruciate ligament (ACL) reconstruction, in order to provide clinical reference.
METHODS:
The literature about the tibial-graft fixation methods on ACL reconstruction at home and abroad was extensively reviewed, and the factors that affect the selection of fixation methods were summarized.
RESULTS:
The knee flexion angle, graft tension, and graft fixation device are mainly considered when the tibial-graft was fixed on ACL reconstruction. At present, the graft is mainly fixed at 0°/30° of knee flexion. The study shows that the knee joint is more stable after fixed at 30°, while the incidence of knee extension limitation decrease after fixed at 0°. In terms of graft tension, a good effectiveness can be obtained when the tension level is close to 90 N or the knee flexion is 30° to recover the affected knee over-restrained 2 mm relative to the healthy knee. In terms of the graft device, the interference screw is still the most commonly used method of tibial-graft fixation, with the development of all-inside ACL reconstruction in recent years, the cortical button fixation may become the mainstream.
CONCLUSION
Arthroscopic reconstruction is the main treatment of ACL rupture at present. However, there is no optimal fixation method for the tibial-graft, the advantages and disadvantages of each fixation methods need to be further studied.
Humans
;
Tibia/surgery*
;
Anterior Cruciate Ligament Reconstruction
;
Knee Joint/surgery*
;
Anterior Cruciate Ligament Injuries/surgery*
;
Bone Screws
10.Finite element analysis of artificial ankle elastic improved inserts.
Zhi XU ; Yuwan LI ; Gang ZOU ; Ying JIN ; Jingcheng RAO ; Shoujin TIAN
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(11):1361-1369
OBJECTIVE:
To discuss the influence of artificial ankle elastic improved inserts (hereinafter referred to as "improved inserts") in reducing prosthesis micromotion and improving joint surface contact mechanics by finite element analysis.
METHODS:
Based on the original insert of INBONE Ⅱ implant system (model A), four kinds of improved inserts were constructed by adding arc or platform type flexible layer with thickness of 1.3 or 2.6 mm, respectively. They were Flying goose type_1.3 elastic improved insert (model B), Flying goose type_2.6 elastic improved insert (model C), Platform type_1.3 elastic improved insert (model D), Platform type_2.6 elastic improved insert (model E). Then, the CT data of right ankle at neutral position of a healthy adult male volunteer was collected, and finite element models of total ankle replacement (TAR) was constructed based on model A-E prostheses by software of Mimics 19.0, Geomagic wrap 2017, Creo 6.0, Hypermesh 14.0, and Abaqus 6.14. Finally, the differences of bone-metal prosthesis interface micromotion and articular surface contact behavior between different models were investigated under ISO gait load.
RESULTS:
The tibia/talus-metal prosthesis interfaces micromotion of the five TAR models gradually increased during the support phase, then gradually fell back after entering the swing phase. The improved models (models B-E) showed lower bone-metal prosthesis interface micromotion when compared with the original model (model A), but there was no significant difference among models A-E ( P>0.05). The maximum micromotion of tibia appeared at the dome of the tibial bone groove, and the micromotion area was the largest in model A and the smallest in model E. The maximum micromotion of talus appeared at the posterior surface of the central bone groove, and there was no difference in the micromotion area among models A-E. The contact area of the articular surface of the insert/talus prosthesis in each group increased in the support phase and decreased in the swing phase during the gait cycle. Compared with model A, the articular surface contact area of models B-E increased, but there was no significant difference among models A-E ( P>0.05). The change trend of the maximum stress on the articular surface of the inserts/talus prosthesis was similar to that of the contact area. Only the maximum contact stress of the insert joint surface of models D and E was lower than that of model A, while the maximum contact stress of the talar prosthesis joint surface of models B-E was lower than that of model A, but there was no significant difference among models A-E ( P>0.05). The high stress area of the lateral articular surface of the improved inserts significantly reduced, and the articular surface stress distribution of the talus prosthesis was more uniform.
CONCLUSION
Adding a flexible layer in the insert can improve the elasticity of the overall component, which is beneficial to absorb the impact force of the artificial ankle joint, thereby reducing interface micromotion and improving contact behavior. The mechanical properties of the inserts designed with the platform type and thicker flexible layer are better.
Adult
;
Male
;
Humans
;
Ankle
;
Ankle Joint/surgery*
;
Finite Element Analysis
;
Tibia/surgery*
;
Talus
;
Stress, Mechanical
;
Biomechanical Phenomena

Result Analysis
Print
Save
E-mail