1.Research on Hospital Operating Room Management System Based on PDA Code Scanning Technology.
Chinese Journal of Medical Instrumentation 2022;46(5):496-502
In view of the high recognition error rate and long scanning time in the existing hospital scanning technology, a new hospital operating room scanning system is designed based on personal digital assistant (PDA). The PDA scanning device adopts PIC16F877A microcontroller of 8 bit for wireless transmission through RFID and bluetooth technology, the code scanning efficiency is greatly improved. In addition, in order to improve the accuracy of image analysis, this study also adopts the energy driven sampling classification algorithm (EDS-CA) to properly preprocess the medical data information received through PDA scanning, then constructs a function classifier, and improves the image processing efficiency according to the EDS-CA reduction process. The experimental results show that the average accuracy of the code scanning system designed in this study is 95%, which proves that PDA code scanning has good performance.
Algorithms
;
Computers, Handheld
;
Hospitals
;
Operating Rooms
;
Technology
2.Automatic Control System of Oxygen Concentration in Medical Hyperbaric Oxygen Chamber Based on ZigBee.
Danna WANG ; Yao CHEN ; Huijun CAO ; Huarui WANG
Chinese Journal of Medical Instrumentation 2022;46(1):47-51
In order to effectively prevent the damage to the human body caused by abnormal oxygen concentration in the medical hyperbaric oxygen chamber, a ZigBee-based medical hyperbaric oxygen chamber oxygen concentration automatic control system is designed. The data acquisition module uses the microprocessor STM32F103C8T6 to receive the oxygen concentration data of each acquisition point, and the ZigBee of the data processing module transmits the processing results to the MSP430G2553 single-chip microcomputer at the receiving end of the slave. The MSP430G2553 single-chip microcomputer uses a self-organizing TS fuzzy neural network (SOTSFNN) and adds activation. The intensity concept realizes automatic control of the oxygen concentration in the hyperbaric oxygen chamber, and controls the buzzer to give an alarm when the oxygen concentration is lower than 19 mg/L and higher than 23 mg/L, and displays the current real-time oxygen concentration through LCD12864. The experimental results show that as the communication distance increases, the packet loss rate of the system is always lower than 5%, and the signal strength under the same communication distance is better; the system can effectively control the oxygen concentration value within the set range, and the oxygen concentration. The control accuracy is high and the stability is good.
Humans
;
Hyperbaric Oxygenation
;
Microcomputers
;
Oxygen
3.Design and Experimental Research of Portable Extracorporeal Circulation Pipeline Performance Testing System.
Song LIU ; Ganying WANG ; Yihan WANG ; Ling PENG ; Jinlu ZHENG
Chinese Journal of Medical Instrumentation 2022;46(2):164-167
Aiming at the current situation of performance testing of hemodialysis extracorporeal circulation tubing, which has slow efficiency, inaccurate measurement, and inconvenient testing, a portable detection system for testing the performance of hemodialysis extracorporeal circulation tubing is designed. The system mainly includes a hardware system and a software system. The hardware system uses STM32F407 single-chip microcomputer as the core to design the driving control of the roller pump; the software system uses the C++ real-time operating system, and the flow detection data is transmitted to the upper computer through RS485 communication and displayed. Experimental showed that the system detects the accuracy and the stability of the flow rate. It has the characteristics of stability and high precision. The relative error of the experimental measurement is within the range of ±10%. The weight of the whole machine is 2 kg, which improves the efficiency by 50% compared with the traditional detection method.
Computers
;
Equipment Design
;
Extracorporeal Circulation
;
Microcomputers
;
Renal Dialysis
;
Software
4.Prevalence and description of digital device use among preschool children: A cross-sectional study in Kota Setar District, Kedah
Tanusha Nathan ; Leelavathi Muthupalaniappen ; Noor Azimah Muhammad
Malaysian Family Physician 2022;17(3):114-120
Introduction:
Digital device helps children enhance academic, cognitive and psychomotor skills. However, prolonged use causes physical inactivity, poor interpersonal skills and communication problems. Information on digital device use among young children in Malaysia is currently limited. Hence, this study aimed to determine the prevalence of digital device utilisation among preschool children in Kota Setar District, Kedah.
Methods:
A cross-sectional study at government preschools in Kota Setar District was conducted from February to April 2020. Selection of preschools and students was done using multistage simple randomisation. A self-administered questionnaire containing demographic and digital device use details was filled by parents.
Results:
The prevalence of digital device use among preschool children was 95.9% and mostly used smartphones (94.2%). Most children (95%) did not own the device, and usage was under supervision (95.7%). The reason for supervision was to prevent exposure to inappropriate content (70.5%). The common reasons for allowing digital device use were for educational (37.4%) and entertainment purposes (36%) through videos (30.9%) and games (30.2%). Approximately 21.5% and 50.3% of the children spent more than 1 and 2 hours on digital devices during weekdays and weekends, respectively.
Conclusion
The prevalence of digital device use among the preschool children in Kota Setar District was very high. Most of them used digital devices for educational and entertainment purposes under parental supervision. However, some exceeded the recommended screen time on weekends. These findings could promote awareness of digital device use among young children and help design public health awareness programmes and future policies.
Child
;
Child, Preschool
;
Prevalence
;
Smartphone
;
Screen time
5.Design of Gas Detection System Based on STM32 Infusion Set.
Song LIU ; Jun SU ; Ling PENG ; Bingrong LIU ; Cheng ZHOU ; Yanqing WANG
Chinese Journal of Medical Instrumentation 2021;45(2):159-162
Aiming at the low efficiency and low quality detection level of the manual infusion set, a gas detection system for infusion set based on STM32 single-chip microcomputer was designed. The detection system includes hardware system design and software system design. The hardware system is based on the STM32F103 single-chip microcomputer. It mainly designs the gas pressure sensor acquisition circuit and the multi-way solenoid valve control circuit. The software system uses a C ++ real-time operating system to ensure system monitoring's real-time performance and validity. Test data is transmitted to the upper computer and displayed via USB serial communication. The experiment proves that the infusion set gas detection system can perform gas detection on the infusion set. The system has the characteristics of stability and high accuracy. The relative error of the experimental measurement is within ±5%, and the detection efficiency is better than manual detection.
Computers
;
Equipment Design
;
Microcomputers
;
Software
6.Industry and workplace characteristics associated with the downloading of a COVID-19 contact tracing app in Japan: a nation-wide cross-sectional study.
Tomohiro ISHIMARU ; Koki IBAYASHI ; Masako NAGATA ; Ayako HINO ; Seiichiro TATEISHI ; Mayumi TSUJI ; Akira OGAMI ; Shinya MATSUDA ; Yoshihisa FUJINO
Environmental Health and Preventive Medicine 2021;26(1):94-94
BACKGROUND:
To combat coronavirus disease 2019 (COVID-19), many countries have used contact tracing apps, including Japan's voluntary-use contact-confirming application (COCOA). The current study aimed to identify industry and workplace characteristics associated with the downloading of this COVID-19 contact tracing app.
METHODS:
This cross-sectional study of full-time workers used an online survey. Multiple logistic regression analysis was used to evaluate the associations of industry and workplace characteristics with contact tracing app use.
RESULTS:
Of the 27,036 participants, 25.1% had downloaded the COCOA. Workers in the public service (adjusted odds ratio [aOR] = 1.29, 95% confidence interval [CI] 1.14-1.45) and information technology (aOR = 1.38, 95% CI 1.20-1.58) industries were more likely to use the app than were those in the manufacturing industry. In contrast, app usage was less common among workers in the retail and wholesale (aOR = 0.87, 95% CI 0.76-0.99) and food/beverage (aOR = 0.81, 95% CI 0.70-0.94) industries, but further adjustment for company size attenuated these associations. Workers at larger companies were more likely to use the app. Compared with permanent employees, the odds of using the app were higher for managers and civil servants but lower for those who were self-employed.
CONCLUSIONS
Downloading of COCOA among Japanese workers was insufficient; thus, the mitigating effect of COCOA on the COVID-19 pandemic is considered to be limited. One possible reason for the under-implementation of the contact tracing app in the retail and wholesale and food/beverage industries is small company size, as suggested by the fully adjusted model results. An awareness campaign should be conducted to promote the widespread use of the contact tracing app in these industries.
Adult
;
COVID-19/prevention & control*
;
Contact Tracing/methods*
;
Cross-Sectional Studies
;
Female
;
Humans
;
Industry/classification*
;
Japan/epidemiology*
;
Male
;
Middle Aged
;
Mobile Applications/statistics & numerical data*
;
SARS-CoV-2
;
Smartphone
;
Workplace/statistics & numerical data*
7.Development and Effect of a Smartphone Overdependence Prevention Program for University Students Based on Self-Determination Theory
Myung Soon KWON ; Jeong Soon YU
Journal of Korean Academy of Nursing 2020;50(1):116-131
PURPOSE: This study aimed to develop a smartphone overdependence prevention program for college students based on the self-determination theory (SDT) and evaluate its effectiveness.METHODS: A non-equivalent control group repeated measures design was used for the study. Participants were 64 university freshmen (experimental group: 29, control group: 35). The developed program consists of eight sessions conducted twice a week. The program was designed to promote autonomy, competence, and relatedness the three elements of the basic psychological needs of self-determination theory. The participants were assessed before the program, immediately after, and 1 and 3 months after the program. Data were collected from April 23 to September 14, 2018 and analyzed by performing a Chi-square test, Fisher's exact test, independent t-test, and repeated measures ANOVA using SPSS/WIN 23.0.RESULTS: This study showed improvement in the basic psychological needs (F=3.90, p =.010) in the experimental group compared to the control group. Specifically, competence (F=2.93, p =.035), relatedness (F=2.89, p =.045), and self-regulatory ability (F=3.11, p =.028) improved significantly.CONCLUSION: Study findings indicate thatthe smartphone overdependence prevention program based on the Self-determination theory could be an effective intervention for improving basic psychological needs and self-regulation ability. Therefore, this program could be an efficient strategy for smartphone overdependence prevention in university students.
Humans
;
Mental Competency
;
Personal Autonomy
;
Self-Control
;
Smartphone
8.Development and Effects of Smartphone App-Based Exercise Program for Hemodialysis Patients
Journal of Korean Academy of Nursing 2020;50(1):52-65
PURPOSE: To examine the effects of a smartphone application-based exercise program on self-efficacy expectations (SEE) and outcome expectations regarding exercise (OEE), physical fitness, activity level, physiological indices, and health-related quality of life in a sample of hemodialysis patients.METHODS: A quasi-experimental control group pre-test post-test design was used. Subjects were recruited from two university hospitals in G city. The subjects were assigned randomly by coin toss: 33 participants to the experimental group and 30 to the control group. A literature review and the self-efficacy theory were used to develop the smartphone program. Experts designed and verified the program to be userfriendly and in consideration of user interaction. Data were collected through a self-report pre-test post-test questionnaire and online medical records.RESULTS: In the experimental group, the levels of physical fitness and physical activity were significantly improved post-test, but the scores on health-related quality of life and the physical indices did not improve. In the experimental group, the SEE and OEE post-test scores were also significantly higher than the pre-test scores, but the control group's scores did not change.CONCLUSION: The smartphone application-based exercise program based on self-efficacy theory significantly improved the level of physical fitness and activity, SEE, and OEE for hemodialysis patients. The use of this application-based exercise program for hemodialysis patients might be an effective nursing intervention tool for improving SEE, OEE, level of physical fitness, and physical activity.
Hospitals, University
;
Humans
;
Medical Records
;
Motor Activity
;
Numismatics
;
Nursing
;
Physical Fitness
;
Quality of Life
;
Renal Dialysis
;
Self Efficacy
;
Smartphone
9.Design of Remote Multi-part Personal Radiation Dose System Based on Bluetooth Communication Module.
Guangguang YAN ; Ting ZHANG ; Jinlin GONG ; Wenjie LI ; Chunhua SHI
Chinese Journal of Medical Instrumentation 2020;44(1):38-41
OBJECTIVE:
A remote multi-part personal radiation dose detection system is designed with ATmega32A single chip microcomputer as the control core.
METHODS:
First of all, the geiger counter tube module collects the radiation signal of the surrouding environment. Secondly, using ATmega32A Microprocessor of Slave computer to calculate the collected signal. Finally, it is sent to the host receiving device or mobile APP through Bluetooth module,so as to realize real-time detection of radiation data, remote transmission and security alarm.
RESULTS:
The system is measured in the same environment as the RG1100 radiometer, with a maximum difference of 0.03 μSv/h.This shows that it can stably realize the functions of radiation measurement, monitoring, alarm, remote connection and multimodal display.
CONCLUSIONS
The system has the advantages of good portability (easy to carry), low power consumption, accurate measurement and so on. It has certain reference value and practicability.
Equipment Design
;
Microcomputers
;
Radiation Dosage
;
Wireless Technology
10.Design of Treatment System for Poor Peripheral Circulation Using Air Wave Pressure Based on STM32 Microprocessor.
Haiyang HU ; Yueming CHEN ; Jilun YE ; Yong XIANG ; Bin WEN ; Yelei WANG
Chinese Journal of Medical Instrumentation 2020;44(1):42-46
This study designs an intermittent pneumatic pressurization device with STM32 series single chip as the core. The working state of the air pump and the plurality of air chambers is controlled by the IO port of the single chip microcomputer, and the circulating inflation of the plurality of air bags is realized. The pressure monitoring system consists of a silicon piezoresistive pressure sensor, a high-precision operational amplifier and a 12-bit AD converter which monitors the gas pressure of each gas path in real time to ensure the safety of the equipment. The system is easy to operate, simple in function, and has strong practicability.
Blood Circulation
;
Cardiovascular System/physiopathology*
;
Equipment Design
;
Humans
;
Microcomputers
;
Pressure


Result Analysis
Print
Save
E-mail