1.Palliative Care and Hospice for Heart Failure Patients: Position Statement From the Korean Society of Heart Failure
Seung-Mok LEE ; Hae-Young LEE ; Shin Hye YOO ; Hyun-Jai CHO ; Jong-Chan YOUN ; Seong-Mi PARK ; Jin-Ok JEONG ; Min-Seok KIM ; Chi Young SHIM ; Jin Joo PARK ; Kye Hun KIM ; Eung Ju KIM ; Jeong Hoon YANG ; Jae Yeong CHO ; Sang-Ho JO ; Kyung-Kuk HWANG ; Ju-Hee LEE ; In-Cheol KIM ; Gi Beom KIM ; Jung Hyun CHOI ; Sung-Hee SHIN ; Wook-Jin CHUNG ; Seok-Min KANG ; Myeong Chan CHO ; Dae-Gyun PARK ; Byung-Su YOO
International Journal of Heart Failure 2025;7(1):32-46
Heart failure (HF) is a major cause of mortality and morbidity in South Korea, imposing substantial physical, emotional, and financial burdens on patients and society. Despite the high burden of symptom and complex care needs of HF patients, palliative care and hospice services remain underutilized in South Korea due to cultural, institutional, and knowledge-related barriers. This position statement from the Korean Society of Heart Failure emphasizes the need for integrating palliative and hospice care into HF management to improve quality of life and support holistic care for patients and their families. By clarifying the role of palliative care in HF and proposing practical referral criteria, this position statement aims to bridge the gap between HF and palliative care services in South Korea, ultimately improving patient-centered outcomes and aligning treatment with the goals and values of HF patients.
2.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
3.Influence of template design on the accuracy of static computer-assisted implant surgery
Jinmook CHUNG ; Junghyun PARK ; Hyeonseong SON ; Seoung-Jin HONG ; Ahran PAE
The Journal of Advanced Prosthodontics 2025;17(1):22-35
PURPOSE:
This study aimed to evaluate the accuracy of static computer-assisted implant surgery (s-CAIS) by comparing the planned and actual positions of implants placed in a partially edentulous model using surgical templates with different sleeve designs.
MATERIALS AND METHODS:
Forty-nine mandibular partially edentulous models were scanned using a model scanner to create standard tessellation language (STL) files. The models were divided into seven groups based on sleeve design: Group 1–4 (Open non-metal sleeves with varying heights (3 mm, 6 mm) and buccal widths (5 mm, 6 mm)), Group 5–6 (Closed non-metal sleeves with heights of 3 mm and 6 mm), and Group 7 (Closed metal sleeve). After implant placement at #45 and #47, STL files were generated and analyzed using 3D measurement software. Deviations were measured in terms of horizontal deviation (coronal and apical), vertical deviation, and angular deviation. Statistical significance was evaluated using the Wilcoxon rank sum test, Kruskal-Wallis test, and multiple generalized linear models.
RESULTS:
While height differences showed no significant deviations (P > .05), there was a tendency for larger apical deviation with increased sleeve height (P < .1). Closed metal and closed non-metal sleeves showed smaller deviations compared to open non-metal sleeves, except in vertical deviation.
CONCLUSION
Closed sleeves demonstrated greater accuracy in s-CAIS compared to open sleeves. Higher sleeves may improve implant placement accuracy, but buccal insertion width did not significantly affect accuracy.
4.Key factors for successful eruption of the mandibular third molar after extraction of the mandibular second molar
Jung Jin PARK ; Yoonjeong NOH ; Yoon Jeong CHOI ; Jae Hyun PARK ; Ji Hyun LEE ; Chooryung Judi CHUNG ; Kyung-Ho KIM
The Korean Journal of Orthodontics 2025;55(2):154-163
Objective:
Extraction of the mandibular second molar (L7) and substitution by the mandibular third molar (L8) is an effective treatment option. This study aimed to evaluate spontaneously erupted L8 occlusion after L7 extraction, and identify the influencing factors.
Methods:
This study assessed 46 L8 from 28 patients using dental study models, panoramic radiographs, and lateral cephalograms obtained during L7 extraction (T1) and completion of L8 eruption (T2). At T2, samples were categorized as acceptable (A-group) or unacceptable (U-group) based on the American Board of Orthodontics index.L8 angulation and position, retromolar space, distance between the Xi point and mandibular first molar (L6), and Nolla stage were compared between the groups to identify the predictive factors for successful eruption.
Results:
At T2, 58.7% of L8 exhibited acceptable occlusion. Age at T1 was significantly higher in the U-group than that in the A-group. Angles ∠6-MnP and ∠8-MnP differed significantly between the groups at T2. Xi-L6 distance was considerably longer in the A-group than that in the U-group at T1 and T2. Younger age at extraction and Xi-L6 distance at T1 affected the acceptable occlusion.
Conclusions
Younger age at L7 extraction and adequate eruption space (Xi-L6 distance) appear to be the key factors for achieving acceptable L8 occlusion.
5.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
6.Influence of template design on the accuracy of static computer-assisted implant surgery
Jinmook CHUNG ; Junghyun PARK ; Hyeonseong SON ; Seoung-Jin HONG ; Ahran PAE
The Journal of Advanced Prosthodontics 2025;17(1):22-35
PURPOSE:
This study aimed to evaluate the accuracy of static computer-assisted implant surgery (s-CAIS) by comparing the planned and actual positions of implants placed in a partially edentulous model using surgical templates with different sleeve designs.
MATERIALS AND METHODS:
Forty-nine mandibular partially edentulous models were scanned using a model scanner to create standard tessellation language (STL) files. The models were divided into seven groups based on sleeve design: Group 1–4 (Open non-metal sleeves with varying heights (3 mm, 6 mm) and buccal widths (5 mm, 6 mm)), Group 5–6 (Closed non-metal sleeves with heights of 3 mm and 6 mm), and Group 7 (Closed metal sleeve). After implant placement at #45 and #47, STL files were generated and analyzed using 3D measurement software. Deviations were measured in terms of horizontal deviation (coronal and apical), vertical deviation, and angular deviation. Statistical significance was evaluated using the Wilcoxon rank sum test, Kruskal-Wallis test, and multiple generalized linear models.
RESULTS:
While height differences showed no significant deviations (P > .05), there was a tendency for larger apical deviation with increased sleeve height (P < .1). Closed metal and closed non-metal sleeves showed smaller deviations compared to open non-metal sleeves, except in vertical deviation.
CONCLUSION
Closed sleeves demonstrated greater accuracy in s-CAIS compared to open sleeves. Higher sleeves may improve implant placement accuracy, but buccal insertion width did not significantly affect accuracy.
7.Key factors for successful eruption of the mandibular third molar after extraction of the mandibular second molar
Jung Jin PARK ; Yoonjeong NOH ; Yoon Jeong CHOI ; Jae Hyun PARK ; Ji Hyun LEE ; Chooryung Judi CHUNG ; Kyung-Ho KIM
The Korean Journal of Orthodontics 2025;55(2):154-163
Objective:
Extraction of the mandibular second molar (L7) and substitution by the mandibular third molar (L8) is an effective treatment option. This study aimed to evaluate spontaneously erupted L8 occlusion after L7 extraction, and identify the influencing factors.
Methods:
This study assessed 46 L8 from 28 patients using dental study models, panoramic radiographs, and lateral cephalograms obtained during L7 extraction (T1) and completion of L8 eruption (T2). At T2, samples were categorized as acceptable (A-group) or unacceptable (U-group) based on the American Board of Orthodontics index.L8 angulation and position, retromolar space, distance between the Xi point and mandibular first molar (L6), and Nolla stage were compared between the groups to identify the predictive factors for successful eruption.
Results:
At T2, 58.7% of L8 exhibited acceptable occlusion. Age at T1 was significantly higher in the U-group than that in the A-group. Angles ∠6-MnP and ∠8-MnP differed significantly between the groups at T2. Xi-L6 distance was considerably longer in the A-group than that in the U-group at T1 and T2. Younger age at extraction and Xi-L6 distance at T1 affected the acceptable occlusion.
Conclusions
Younger age at L7 extraction and adequate eruption space (Xi-L6 distance) appear to be the key factors for achieving acceptable L8 occlusion.
8.Vitamin D Attenuates Non-Alcoholic Fatty Liver Disease in High-Fat Diet-Induced Obesity Murine Model
Sook In CHUNG ; Lin LIANG ; Heejae HAN ; Kyung Hee PARK ; Jae-Hyun LEE ; Jung-Won PARK
Yonsei Medical Journal 2025;66(2):75-86
Purpose:
Obesity and metabolic syndrome are acknowledged as key factors contributing to the development of non-alcoholic fatty liver disease (NAFLD). Vitamin D (VitD) is a multifaceted secosteroid hormone known for its anti-fibrotic and anti-inflammatory properties, with its deficiency often linked to obesity. Our study aimed to investigate whether VitD supplementation could mitigate the liver pathology associated with NAFLD.
Materials and Methods:
The NAFLD model was developed by subjecting male C57BL/6 mice to a high-fat diet (HFD) for 14 weeks.These mice were supplemented with VitD through intraperitoneal injection at a dosage of 7 μg/kg, administered three times per week for 7 weeks.
Results:
HFD resulted in VitD deficiency, insulin resistance, and increased liver weight. It elevated serum levels of liver aminotransferases and triglyceride, ultimately leading to steatohepatitis with fibrosis. This model exhibited increased levels of transforming growth factor (TGF)-β1, pro-inflammatory cytokines, HNF4α transcription factors, reactive oxygen species (ROS), renin-angiotensin system activity, and epithelial-mesenchymal transitions (EMT) within the liver. Supplementation with VitD resulted in the recovery of liver weight, improvement in histologic features associated with steatohepatitis, and reduction in alanine aminotransferases and triglyceride levels induced by the HFD. Additionally, it mitigated the HFD-induced over-expressions of TGF-β1 and fibrosis-related genes, along with pro-inflammatory cytokines and ROS. Notably, no adverse effect was found due to VitD supplementation in this model.
Conclusion
VitD ameliorates steatohepatitis within obesity-induced NAFLD through its multifaceted pathways. VitD supplementation emerges as a potentially safe, cost-effective, and direct treatment approach for NAFLD patients dealing with obesity or metabolic dysfunction.
9.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
10.Influence of template design on the accuracy of static computer-assisted implant surgery
Jinmook CHUNG ; Junghyun PARK ; Hyeonseong SON ; Seoung-Jin HONG ; Ahran PAE
The Journal of Advanced Prosthodontics 2025;17(1):22-35
PURPOSE:
This study aimed to evaluate the accuracy of static computer-assisted implant surgery (s-CAIS) by comparing the planned and actual positions of implants placed in a partially edentulous model using surgical templates with different sleeve designs.
MATERIALS AND METHODS:
Forty-nine mandibular partially edentulous models were scanned using a model scanner to create standard tessellation language (STL) files. The models were divided into seven groups based on sleeve design: Group 1–4 (Open non-metal sleeves with varying heights (3 mm, 6 mm) and buccal widths (5 mm, 6 mm)), Group 5–6 (Closed non-metal sleeves with heights of 3 mm and 6 mm), and Group 7 (Closed metal sleeve). After implant placement at #45 and #47, STL files were generated and analyzed using 3D measurement software. Deviations were measured in terms of horizontal deviation (coronal and apical), vertical deviation, and angular deviation. Statistical significance was evaluated using the Wilcoxon rank sum test, Kruskal-Wallis test, and multiple generalized linear models.
RESULTS:
While height differences showed no significant deviations (P > .05), there was a tendency for larger apical deviation with increased sleeve height (P < .1). Closed metal and closed non-metal sleeves showed smaller deviations compared to open non-metal sleeves, except in vertical deviation.
CONCLUSION
Closed sleeves demonstrated greater accuracy in s-CAIS compared to open sleeves. Higher sleeves may improve implant placement accuracy, but buccal insertion width did not significantly affect accuracy.

Result Analysis
Print
Save
E-mail