1.Prevalence of thyroid nodules and its association with metabolic syndrome in physical examination population of Mianyang Region
Yanlin PU ; Haitao XU ; Fang HE ; Jianrong SU ; Huiying ZHAO ; Yaozhou JIA ; Li LIU
Journal of Public Health and Preventive Medicine 2026;37(3):151-154
Objective To investigate the prevalence of thyroid nodules in the physical examination population in Mianyang region and analyze its association with metabolic syndrome. Methods A retrospective study was conducted on 9 978 individuals who underwent health examinations at our hospital from January 2024 to May 2025. Thyroid examinations were performed using color Doppler ultrasound to analyze the prevalence of thyroid nodules in this population. Clinical data of all subjects were collected, and logistic regression analysis was employed to assess the association between metabolic syndrome and the risk of thyroid nodule development. Results The prevalence of thyroid nodules in the physical examination population of Mianyang region was 17.98% (1 794/9 978). The logistic regression results showed that after adjusting for gender, age, BMI, occupation, consumption of non-iodized salt, staying up late, daily sleep duration, anxiety, and depression, metabolic syndrome (OR=6.593, 95% CI: 3.961-10.975) was associated with thyroid nodules (P<0.05). Conclusion The prevalence of thyroid nodules among the physical examination population in the Mianyang area is 17.98%, and metabolic syndrome remains associated with the risk of thyroid nodules after effectively controlling for confounding factors.
2.Accuracy of Magnetic Resonance Spectroscopy–Detected Fumarate Peak for Diagnosing Fumarate Hydratase Deficiency in Uterine Leiomyomas: A Prospective Study
Guiqin LIU ; Wenxin YU ; Shihang PAN ; Yuansheng LUO ; Jingli CHEN ; Mengying ZHU ; Zaoyu WANG ; Yang SONG ; Jin ZHANG ; Jianrong XU ; Yan ZHOU ; Jun MA ; Guangyu WU
Korean Journal of Radiology 2026;27(5):440-451
Objective:
To evaluate the diagnostic performance of magnetic resonance spectroscopy (MRS) in discriminating fumarate hydratase-deficient (FH-d) uterine leiomyomas (ULs) from FH-preserved ULs.
Materials and Methods:
This study consisted of three stages, with independent cohorts recruited for each stage: 1) sample-size estimation was retrospectively performed on UL specimens (diameter ≥3 cm; age, 20–40 years) from our database with immunohistochemistry (IHC) for 2-succinocysteine (2-SC) as the reference, without genetic testing, 2) MRS sequence optimization in confirmed FH germline mutation participants with ultrasound-detected ULs (diameter ≥3 cm), without IHC analysis, and 3) prospective diagnostic test accuracy was evaluated in consecutive participants with ultrasound-detected ULs (diameter ≥3 cm;age, 20–40 years), using IHC for 2-SC for determining the FH status and subsequent genetic testing in those with positive 2-SC results to identify whether FH mutations were germline or somatic in origin. The choline and fumarate peaks in MRS were classified as positive, negative, or technical failure (TF). TFs were analyzed separately and excluded from the primary diagnostic accuracy calculations. T1-, T2-, and diffusion-weighted images were interpreted as hyperintense or hypointense. The enhancement rate and apparent diffusion coefficient were also acquired. Diagnostic performance was compared between MRS and various magnetic resonance imaging (MRI) features.
Results:
The optimal MRS parameters for the fumarate peak were echo time (TE) = 140 ms and an average of 256. Among the 360 prospective participants, 37 were confirmed to have FH-dULs. MRS showed positive fumarate peaks in 35 of 37 FH-dULs.After excluding six TFs, the positive fumarate peak on MRS showed 94.6% (35/37) sensitivity, 99.7% (316/317) specificity, and 99.2% (351/354) accuracy, all of which were significantly superior to those of other MRI features (P ≤ 0.002).
Conclusion
A positive fumarate peak on MRS may be a useful imaging biomarker for diagnosing FH-dULs.
3.Expert consensus on infection prevention and control of Creutzfeldt-Jakob disease in medical institutions
Tianxiang GE ; Yangyang JIA ; Chunhui LI ; Jianrong HUANG ; Xiujuan MENG ; Xiaodong GAO ; Jingping ZHANG ; Fu QIAO ; Lijuan XIONG ; Hui LIANG ; Wei LI ; Haiyan LOU ; Wenjuan WU ; Tianxin XIANG ; Jiansen CHEN ; Biao ZHU ; Kaijin XU ; Zhihui ZHOU ; Hongliu CAI ; Meihong YU ; Yan ZHANG ; Yanwan SHANGGUAN ; Haiting FENG ; Hangping YAO ; Lei GUO ; Tieer GAN ; Weihong ZHANG ; Jimin SUN ; Ye LU ; Qun LU ; Meng CAI ; Jin SHEN ; Yunsong YU ; Anhua WU ; Liu-yi LI ; Tingting QU
Chinese Journal of Infection Control 2025;24(4):437-450
Creutzfeldt-Jakob disease(CJD)is a rapidly progressive and fatal neurodegenerative disorder caused by prions,with certain infectivity and iatrogenic transmission risks.With the rapid progress and application of new dia-gnostic biomarkers and detection methods,as well as the construction and improvement of surveillance and reporting systems,the detection of CJD in patients domestically and internationally has shown an increasing trend year by year.Due to its long incubation period and heterogeneity of early symptoms,early identification and diagnosis of the disease is difficult,increasing the risk of transmission within medical institutions.Currently,there is a lack of con-sensus on the infection prevention and control of CJD.In order to timely identify and diagnose CJD as well as effec-tively block its transmission in medical institutions,this consensus summarizes 15 clinical concerns and formulates 24 specific recommendations based on the latest domestic and international research findings and clinical evidence,as well as combines with clinical practice,aiming to standardize healthcare-associated infection prevention and control measures for CJD and reduce its transmission risk in medical institutions.
4.Evaluation of the effect of health education based on transtheoretical model on pulmonary rehabilitation exercise in elderly patients with COPD
Huimin WEN ; Qicang LIU ; Jianrong LI
Chongqing Medicine 2025;54(7):1642-1647
Objective To evaluate the effect of health education based on the transtheoretical model on pulmonary rehabilitation exercise in elderly outpatients with chronic obstructive pulmonary disease(COPD).Methods From January 2022 to April 2023,118 COPD patients from the internal medicine outpatient clinic of Beijing Tongren Hospital,Capital Medical University,were selected as study subjects and randomly divided in-to a control group and observation group using a random number table,with 59 patients in each group;the control group received routine health education,while the intervention group received health education guided by the transtheoretical model on top of the control group's regimen,with different health education strategies provided according to the patients'behavioral stages,and comparisons were made between the two groups be-fore and after the intervention in terms of quality of life,pulmonary function,blood gas analysis,inflammatory factors,modified Medical Research Council(mMRC)dyspnea scale,and 6-minute walk test(6MWD).Results After the intervention,there were statistically significant differences between the two groups in scores on the Short Form-36 Health Survey(SF-36),forced expiratory volume in one second(FEV1),percent-age of predicted forced expiratory volume in one second(FEV1%pred),partial pressure of oxygen(PaO2),levels of tumor necrosis factor-alpha(TNF-α),C-reactive protein(CRP),interleukin-6(IL-6),mMRC score,and 6MWD(P<0.05).Conclusion Health education guided by the transtheoretical model has significant ap-plication value in elderly outpatients with COPD and is worthy of further promotion in clinical practice.
5.Tubeless subxiphoid uniportal video-assisted thoracoscopic surgery with percutaneous suspension technique via balance-shaped sternal elevation device in anterior mediastinal masses
Junmin ZHU ; Junjie WANG ; Jianming YUE ; Yixin SUN ; Yichen LIU ; Lei WANG ; Lin LIN ; Jie LI ; Jinlan ZHAO ; Xuehua TU ; Ningying DING ; Jianrong HU ; Chunmei HE ; Leilei TIAN ; Hongtao TANG ; Jiasheng ZHAO ; Cheng CHEN ; Yongxiang SONG ; Yunwei TIAN ; Yong XIAO ; Kaidi LI ; Lin MA ; Yun WANG ; Longqi CHEN ; Dong TIAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(11):1603-1609
Objective To assess the clinical value of a novel surgical technique—Tubeless subxiphoid uniportal video-assisted thoracoscopic surgery with percutaneous suspension technique via balance-shaped sternal elevation device in the resection of anterior mediastinal masses. Methods Patients who underwent tubeless subxiphoid uniportal video-assisted thoracoscopic surgery via balance-shaped sternal elevation device in anterior mediastinal masses process at the Department of Thoracic Surgery, West China Hospital, Sichuan University from March to April 2025 were included, and their clinical data were analyzed. Results A total of 4 patients were included, with 2 males and 2 females, aged 58-75 years. The diameter of the tumor was 2.5-3.0 cm. The operation time was 60.0-150.0 min, intraoperative blood loss was 5-10 mL, pain score on the 3rd day after surgery was 0 points, and postoperative hospital stay was 2-3 days. All patients achieved complete resection of the masses and thymus without perioperative complications. Conclusion The tubeless subxiphoid uniportal video-assisted thoracoscopic surgery with percutaneous suspension technique via balance-shaped sternal elevation device technique optimizes surgical visualization and instrument maneuverability while avoiding complications related to conventional anesthesia and tubing, thereby markedly enhancing the minimally invasive profile of anterior mediastinal masses resections. In addition to maintaining procedural safety, this approach effectively reduces postoperative pain and accelerates patient recovery, highlighting its potential for widespread clinical adoption.
6.Effects of psychological state on setup errors of radiotherapy for patients with breast cancer
Wei ZHANG ; Shirui QIN ; Fukui HUAN ; Hongju LI ; Bofei LIU ; Wenbo ZHANG ; Lu HOU ; Kun ZHANG ; Shijia WANG ; Shulian WANG ; Jianrong DAI
Cancer Research and Clinic 2025;37(5):362-365
Objective:To investigate the effects of psychological state on the setup errors of radiotherapy for breast cancer patients.Methods:A prospective cohort study was conducted. A total of 193 breast cancer patients in Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College from October 2022 to May 2023 were selected. Radiotherapy was performed after fixation with an integrated multi-functional device for the head, chest and abdomen. Psychological status of patients was assessed by using 9-item health questionnaire (PHQ-9) and generalized anxiety disorder 7 self-rating scale (GAD-7) before first radiotherapy, the 10th radiotherapy and the last radiotherapy. Based on the results of the questionnaires, patients were divided into psychological problem (anxiety or depression) group and non-psychological problem group. The general data and setup errors of radiotherapy in both groups were compared.Results:All the 193 patients were female, with a median age of 47 years. There were 53 patients in psychological problem group and they underwent a total of 507 image-guided procedures, with setup errors [ M ( Q1, Q3)] of 0.18 (0.07, 0.33), 0.20 (0.10, 0.33) and 0.19 (0.09, 0.30) in the left-right (X), superior-inferior (Y), and anterior-posterior (Z) directions, respectively; the remaining 140 patients in non-psychological problem group underwent 1 240 image-guided procedures, with setup errors [ M ( Q1, Q3)]of 0.17 (0.08, 0.30), 0.20 (0.10, 0.30) and 0.18 (0.09, 0.28) in the X, Y, and Z directions, respectively, and the differences were statistically significant ( Z values were -3.78, -2.00; P < 0.001, P = 0.046). Conclusions:Anxiety and depression have an influence on the setup errors of radiotherapy in patients with breast cancer. In the processs of radiotherapy for breast cancer, it is important to pay attention to the psychological status of patients.
7.Establishment of a"#-shaped"method of radiotherapy marking of reflecting the range of respiratory motion in radiotherapy
Chenlei GUO ; Ying CAO ; Xin FENG ; Kaixuan ZHANG ; Zhen WANG ; Mingjian SUN ; Yongli SONG ; Xing LIU ; Wenyang LIU ; Jianrong DAI
China Medical Equipment 2025;22(8):52-56
Objective:To propose a novel radiotherapy marking method-the"#"-character method,which aimed at improving the accuracy and repeatability of positioning during radiotherapy.Methods:A specially"cross-shaped"stamp was designed by this study,which consisted of a handheld square base with a"cross-shaped"protrusion.Using this stamp,the extreme positions of end-expiration and end-inspiration were marked respectively at the laser-guided regions on the directly above and bilateral sides of the patient's body,and each position was printed a"+"character.Finally,a"#-shaped"signal was formed,which represented the full range of respiratory motion of patients.The study included two parts:surface displacement caused by respiration was simulated through a three-dimensional(3D)motion platform,which was used to conduct a phantom experiment for anthropomorphic dummy,A randomized controlled study involving 40 patients,who were treated between January and June 2024 at the Department of Radiotherapy,Cancer Hospital,Chinese Academy of Medical Sciences,were conducted.The cohort included 20 patients with breast tumor(Positioning the outer contour by exposing the chest)and 20 patients with thoracic tumor(fixed position of using thermoplastic film).These patients were divided into two groups for comparison,which received respectively the"#-shaped"method and the conventional"+-shaped"method.The cone-beam computed tomography(CBCT)images before treatment were used to compare the influences of the two kinds of marking methods on the positioning errors of patients with breast tumor and patients with thoracic tumor.Then,the statistical analysis was used to assess precision and accuracy of positioning.Results:The result of phantom experiment indicated that the positioning error of the"#-shaped"method was significantly better than that of the"+-shaped"method under various parameters of respiratory movement.Under three kinds of different respiratory cycles(3,4,and 5 seconds)and amplitudes(8,12,and 15 mm),the positioning errors of the"#-shaped"method were respectively(0.15±0.04)cm,(0.19±0.05)cm and(0.35±0.14)cm,while the"+-shaped"method were respectively(0.42±0.16)cm,(0.64±0.28)cm and(0.88±0.37)cm,and the differences were statistically significant(t=8.347,3.416,2.901,P<0.05).The results of actual patients indicated the positioning error[(0.97±0.32)cm]of the"#-shaped"method was significantly lower than[(1.62±0.47)cm]of the"+-shaped"method for patients with breast tumor(Positioning the outer contour by exposing the chest),and the difference was significant(t=3.615,P<0.05).On the other hand,the positioning error[(0.69±0.24)cm]of the"#-shaped"method was significantly lower than[(0.97±0.39)cm]of the"+-shaped"method for patients with thoracic tumor(fixed position of using thermoplastic film),and the difference also was significant(t=1.934,P<0.05).Conclusion:Compared to the conventional"+-shaped"method,the"#-shaped"method appears higher accuracy and repeatability during the positioning process of radiotherapy,which especially is suitable to the treatment for breast tumor and thoracic tumor that need accurately control the influences of respiratory motion.
8.Expert consensus on infection prevention and control of Creutzfeldt-Jakob disease in medical institutions
Tianxiang GE ; Yangyang JIA ; Chunhui LI ; Jianrong HUANG ; Xiujuan MENG ; Xiaodong GAO ; Jingping ZHANG ; Fu QIAO ; Lijuan XIONG ; Hui LIANG ; Wei LI ; Haiyan LOU ; Wenjuan WU ; Tianxin XIANG ; Jiansen CHEN ; Biao ZHU ; Kaijin XU ; Zhihui ZHOU ; Hongliu CAI ; Meihong YU ; Yan ZHANG ; Yanwan SHANGGUAN ; Haiting FENG ; Hangping YAO ; Lei GUO ; Tieer GAN ; Weihong ZHANG ; Jimin SUN ; Ye LU ; Qun LU ; Meng CAI ; Jin SHEN ; Yunsong YU ; Anhua WU ; Liu-yi LI ; Tingting QU
Chinese Journal of Infection Control 2025;24(4):437-450
Creutzfeldt-Jakob disease(CJD)is a rapidly progressive and fatal neurodegenerative disorder caused by prions,with certain infectivity and iatrogenic transmission risks.With the rapid progress and application of new dia-gnostic biomarkers and detection methods,as well as the construction and improvement of surveillance and reporting systems,the detection of CJD in patients domestically and internationally has shown an increasing trend year by year.Due to its long incubation period and heterogeneity of early symptoms,early identification and diagnosis of the disease is difficult,increasing the risk of transmission within medical institutions.Currently,there is a lack of con-sensus on the infection prevention and control of CJD.In order to timely identify and diagnose CJD as well as effec-tively block its transmission in medical institutions,this consensus summarizes 15 clinical concerns and formulates 24 specific recommendations based on the latest domestic and international research findings and clinical evidence,as well as combines with clinical practice,aiming to standardize healthcare-associated infection prevention and control measures for CJD and reduce its transmission risk in medical institutions.
9.Diagnostic value of epicardial adipose tissue thickness combined with serum ADAM10 and STIM1 for coronary heart disease
Peilu XU ; Jianmin QIAO ; Jing LI ; Jianrong LIU ; Shujun CHEN ; Chunpeng JI
Tianjin Medical Journal 2025;53(9):963-967
Objective To explore the diagnostic value of epicardial adipose tissue(EAT)thickness combined with serum disintegrin metalloprotease 10(ADAM10)and stromal interaction molecule 1(STIM1)in coronary heart disease(CHD).Methods A total of 119 CHD patients were included as the study group,and 100 non-CHD patients in the same period were selected as the control group.The clinical data of the patients were collected.Serum ADAM10 and STIM1 levels were detected by enzyme-linked immunosorbent assay(ELISA).Color Doppler ultrasonography was applied to detect EAT thickness.Multivariate Logistic regression was used to analyze influencing factors of CHD occurrence.The diagnostic value of EAT thickness combined with serum ADAM10 and STIM1 levels in the diagnosis of CHD was analyzed by subject work characteristics(ROC)curves.Results The levels of triglycerides,low-density lipoprotein cholesterol(LDL-C),EAT thickness,serum ADAM10 and STIM1 were higher in the study group than those in the control group(P<0.05).Logistic regression analysis showed that elevated EAT thickness,serum ADAM10,STIM1,triglyceride and LDL-C levels were independent risk factors for the occurrence of CHD(P<0.05).ROC curve analysis showed that the area under the curve of EAT thickness combined with serum ADAM10 and STIM1 for the diagnosis of CHD[0.864(95%CI:0.811-0.907)]was higher than that of their respective individual diagnoses[0.801(95%CI:0.741-0.851),0.750(95%CI:0.687-0.806),respectively,0.799(95%CI:0.740-0.850)],and the sensitivity and specificity of the combined diagnosis were 82.35%and 83.00%,respectively.Conclusion EAT thickness,serum ADAM10 and STIM1 levels are obviously elevated in CHD patients,and the combination of the three tests has a high diagnostic value for CHD.
10.Establishment of a"#-shaped"method of radiotherapy marking of reflecting the range of respiratory motion in radiotherapy
Chenlei GUO ; Ying CAO ; Xin FENG ; Kaixuan ZHANG ; Zhen WANG ; Mingjian SUN ; Yongli SONG ; Xing LIU ; Wenyang LIU ; Jianrong DAI
China Medical Equipment 2025;22(8):52-56
Objective:To propose a novel radiotherapy marking method-the"#"-character method,which aimed at improving the accuracy and repeatability of positioning during radiotherapy.Methods:A specially"cross-shaped"stamp was designed by this study,which consisted of a handheld square base with a"cross-shaped"protrusion.Using this stamp,the extreme positions of end-expiration and end-inspiration were marked respectively at the laser-guided regions on the directly above and bilateral sides of the patient's body,and each position was printed a"+"character.Finally,a"#-shaped"signal was formed,which represented the full range of respiratory motion of patients.The study included two parts:surface displacement caused by respiration was simulated through a three-dimensional(3D)motion platform,which was used to conduct a phantom experiment for anthropomorphic dummy,A randomized controlled study involving 40 patients,who were treated between January and June 2024 at the Department of Radiotherapy,Cancer Hospital,Chinese Academy of Medical Sciences,were conducted.The cohort included 20 patients with breast tumor(Positioning the outer contour by exposing the chest)and 20 patients with thoracic tumor(fixed position of using thermoplastic film).These patients were divided into two groups for comparison,which received respectively the"#-shaped"method and the conventional"+-shaped"method.The cone-beam computed tomography(CBCT)images before treatment were used to compare the influences of the two kinds of marking methods on the positioning errors of patients with breast tumor and patients with thoracic tumor.Then,the statistical analysis was used to assess precision and accuracy of positioning.Results:The result of phantom experiment indicated that the positioning error of the"#-shaped"method was significantly better than that of the"+-shaped"method under various parameters of respiratory movement.Under three kinds of different respiratory cycles(3,4,and 5 seconds)and amplitudes(8,12,and 15 mm),the positioning errors of the"#-shaped"method were respectively(0.15±0.04)cm,(0.19±0.05)cm and(0.35±0.14)cm,while the"+-shaped"method were respectively(0.42±0.16)cm,(0.64±0.28)cm and(0.88±0.37)cm,and the differences were statistically significant(t=8.347,3.416,2.901,P<0.05).The results of actual patients indicated the positioning error[(0.97±0.32)cm]of the"#-shaped"method was significantly lower than[(1.62±0.47)cm]of the"+-shaped"method for patients with breast tumor(Positioning the outer contour by exposing the chest),and the difference was significant(t=3.615,P<0.05).On the other hand,the positioning error[(0.69±0.24)cm]of the"#-shaped"method was significantly lower than[(0.97±0.39)cm]of the"+-shaped"method for patients with thoracic tumor(fixed position of using thermoplastic film),and the difference also was significant(t=1.934,P<0.05).Conclusion:Compared to the conventional"+-shaped"method,the"#-shaped"method appears higher accuracy and repeatability during the positioning process of radiotherapy,which especially is suitable to the treatment for breast tumor and thoracic tumor that need accurately control the influences of respiratory motion.


Result Analysis
Print
Save
E-mail