1.Normal Penile Size and Self Esteem about Penile Size of the Third Decade Men in Korea.
Korean Journal of Urology 1999;40(8):1037-1042
PURPOSE: The penile augmentation operation is getting popular in Korea, but we don`t have enough data about normal penile length distribution of Korean male and their self-esteem about their penile size. So I investigated the flaccid and erect penile sizes of young Korean males and their penile size complex or pride if any. This study data could be a step stone to establish better operation indication and patient consultation. MATERIALS AND METHODS: After explanation and agreement to the purpose and methods of this study, 171 Korean male in early 20`s who visit our institution were take part in. I measured their pre-pubic bone fat pad depth, flaccid penile length, flaccid mid-shaft circumferences and stretched length under warm and comfortable private environment. Then erect penile lengths and mid-shaft circumferences were measured after self-stimulation which was tried two times if needed. I used rigid ruler except the measuring of penile circumference to avoid measurement bias originated from penile skin curvature. Then they were asked to answer several questions including, `How do you think about your penile size?`, `Why do you think so?'. I used the correlation analysis and the student t-test to analyze our data statistically. RESULTS: Total number of study subject who can get sufficient erection is 156 among 171 subjects. In 156 subjects, mean flaccid length, flaccid circumference, erect length and erect circumference were 6.1+/-1.3cm, 8.9+/-0.8cm, 10.8+/-1.3cm and 11.3+/-1.2cm(Table 1). Mean stretched length was 9.6+/-1.2cm and the stretched length most closely correlated with the erect length(r=0.81)(Table 2). Mean fat pad depth was 1.1+/-0.4cm and mean functional penile length, the sum of erect length and fat pad depth, was 11.9+/-1.3cm. In 156 subjects, the answer about penile size were 7(4.5%) `very small`, 32(20.5%) `small`, 110(70.5%) `normal`, 7(4.5%) `large`, and no `very large`(Table 3). And most of them compared their penile size with others at rest room or rocker room. CONCLUSIONS: This study demonstrated that more Korean young males think their penile size is small rather than large. And their penile self-esteem is based on their flaccid length mostly. To define the length guideline of penile augmentation, I used flaccid length 3.5cm and erect length 8.2cm as reference values which are 2 standard deviation below from the average among normal distribution. In consultation of the patient who want penile augmentation, urologist should consider the tendency of low self-esteem about penile size and the distribution of flaccid and erect penile size of young Korean male.
Adipose Tissue
;
Bias (Epidemiology)
;
Humans
;
Korea*
;
Male
;
Reference Values
;
Self Concept*
;
Skin
2.Successful Removal of an Intravesical Electrical Wire Cable.
The World Journal of Men's Health 2014;32(2):120-122
A few previous reports have described cases wherein electrical wire cables were inserted into the male urethra and bladder. Electrical wire cables are available at home and are easy to insert. However, after they coil in the patient's bladder, they are difficult to remove. In February 2013, a 30-year-old man presented to the emergency room of SMG-SNU Boramae Medical Center with a urethral foreign body. He had inserted an electrical wire cable into his urethra for the purpose of masturbation, despite having a regular sex partner and no underlying disease. A kidney-ureter-bladder radiography showed a tangled wire in his bladder and urethra. On the next day, we tried to remove the wire cystoscopically, but this proved to be impossible because of complex coiling and the slippery surface of the wire. A Pfannenstiel incision was made to remove the foreign body. No postoperative complications were noted.
Adult
;
Emergency Service, Hospital
;
Foreign Bodies
;
Humans
;
Male
;
Masturbation
;
Postoperative Complications
;
Radiography
;
Urethra
;
Urinary Bladder
3.Successful Removal of an Intravesical Electrical Wire Cable.
The World Journal of Men's Health 2014;32(2):120-122
A few previous reports have described cases wherein electrical wire cables were inserted into the male urethra and bladder. Electrical wire cables are available at home and are easy to insert. However, after they coil in the patient's bladder, they are difficult to remove. In February 2013, a 30-year-old man presented to the emergency room of SMG-SNU Boramae Medical Center with a urethral foreign body. He had inserted an electrical wire cable into his urethra for the purpose of masturbation, despite having a regular sex partner and no underlying disease. A kidney-ureter-bladder radiography showed a tangled wire in his bladder and urethra. On the next day, we tried to remove the wire cystoscopically, but this proved to be impossible because of complex coiling and the slippery surface of the wire. A Pfannenstiel incision was made to remove the foreign body. No postoperative complications were noted.
Adult
;
Emergency Service, Hospital
;
Foreign Bodies
;
Humans
;
Male
;
Masturbation
;
Postoperative Complications
;
Radiography
;
Urethra
;
Urinary Bladder
4.Percutaneous Nephrostomy in Infants and Children.
Hwancheol SON ; Kwang Myung KIM ; Hwang CHOI
Korean Journal of Urology 1996;37(2):163-168
Percutaneous nephrostomy (PCN) is an established technique in urology but there have been few reports in pediatric urology. We reviewed retrospectively 48 cases for evaluation of the indication, results, complications, and the methods of follow-up after PCN. From October '85 to December '95, on 50 kidneys of 48 patients, 64 PCN were performed. Male patients were predominant (39:9). The indication of PCN were the functional evaluation of huge hydronephrotic kidneys (23 PCN), the relieve of urinary obstruction (10), the urinary diversion (9), the urinary tract infection (11), the differential diagnosis of hydronephrosis (1) and re-PCN after catheter displacement or obstruction (10). 23 patients for the functional evaluation of huge hydronephrotic kidneys that had poor function in the intravenous pyelography or the radioisotope renal scan, and/or the thin parenchyme in ultrasound, had got the regular follow-up with check of the daily urine output, the creatinine clearance after 2-14 days. 19 who showed good urine output (200-1000ml/day) and good creatinine clearance (average 22.4% of total creatinine clearance) after 2-14 days, were managed by reconstructive surgery and nephrectomy was performed in 4 patients who showed poor urine output (less than 10 ml/ day) or poor creatinine clearance( 1.1 and 3.5 % of total creatinine clearance). After PCN, there were mild infection in 3 cases and no serious complication. But there were catheter displacement in 13 cases and catheter obstruction in 3 cases, and in 13 cases of catheter displacement, 8 (53.3%, 8/15) were under 1 year-old, 4 (25%, 4/16) were between 1 and 5 year-old, and 1 (5.9%, 1/17) was over 6 year-old. In 2 cases of UPJ obstruction, the thickening of renal pelvis had made pyeloplasty difficult. Our data shows that a brief period (within 2 weeks) of nephrostomy drainage allows the kidney to display its potential for recovery of function, as measured by differential creatinine clearance and daily urine output. In pediatrics, PCN should be performed carefully in the selected cases and the duration of nephrostomy should be shortened as possible.
Catheter Obstruction
;
Catheters
;
Child*
;
Child, Preschool
;
Creatinine
;
Diagnosis, Differential
;
Drainage
;
Follow-Up Studies
;
Humans
;
Hydronephrosis
;
Infant*
;
Kidney
;
Kidney Pelvis
;
Male
;
Nephrectomy
;
Nephrostomy, Percutaneous*
;
Pediatrics
;
Pregnenolone Carbonitrile
;
Recovery of Function
;
Retrospective Studies
;
Ultrasonography
;
Urinary Diversion
;
Urinary Tract Infections
;
Urography
;
Urology
5.Current trends in minimally invasive surgery for benign prostatic hyperplasia
Journal of the Korean Medical Association 2020;63(2):119-125
The prevalence of benign prostatic hyperplasia (BPH) is rising with Korea becoming an aging society. As patients age, their comorbidities and the risks associated with anesthesia increase. Recently, there has been an increasing concern regarding sexual function after surgery. As a result, interest in minimally invasive surgery for BPH that does not require anesthesia or affect sexual function has grown. This review article introduces newly developed minimally invasive surgeries for BPH divided into four categories based on the strategy—mechanical, anatomical, atrophic, and laparoscopic. Here, the mechanisms for each surgical method have been introduced. Furthermore, recent representative studies of these procedures with a focus on randomized controlled trials and meta-analyses have also been reviewed. Side effects related to sexual function have also been mentioned briefly along with the efficacy and indication for robotic BPH surgery, which has recently been attracting attention. However, these newer, minimally invasive procedures require additional comparative randomized controlled trials and long-term results to produce more robust evidence for their use.
6.Current trends in minimally invasive surgery for benign prostatic hyperplasia
Journal of the Korean Medical Association 2020;63(2):119-125
The prevalence of benign prostatic hyperplasia (BPH) is rising with Korea becoming an aging society. As patients age, their comorbidities and the risks associated with anesthesia increase. Recently, there has been an increasing concern regarding sexual function after surgery. As a result, interest in minimally invasive surgery for BPH that does not require anesthesia or affect sexual function has grown. This review article introduces newly developed minimally invasive surgeries for BPH divided into four categories based on the strategy—mechanical, anatomical, atrophic, and laparoscopic. Here, the mechanisms for each surgical method have been introduced. Furthermore, recent representative studies of these procedures with a focus on randomized controlled trials and meta-analyses have also been reviewed. Side effects related to sexual function have also been mentioned briefly along with the efficacy and indication for robotic BPH surgery, which has recently been attracting attention. However, these newer, minimally invasive procedures require additional comparative randomized controlled trials and long-term results to produce more robust evidence for their use.
7.Current trends in minimally invasive surgery for benign prostatic hyperplasia
Journal of the Korean Medical Association 2020;63(2):119-125
The prevalence of benign prostatic hyperplasia (BPH) is rising with Korea becoming an aging society. As patients age, their comorbidities and the risks associated with anesthesia increase. Recently, there has been an increasing concern regarding sexual function after surgery. As a result, interest in minimally invasive surgery for BPH that does not require anesthesia or affect sexual function has grown. This review article introduces newly developed minimally invasive surgeries for BPH divided into four categories based on the strategy—mechanical, anatomical, atrophic, and laparoscopic. Here, the mechanisms for each surgical method have been introduced. Furthermore, recent representative studies of these procedures with a focus on randomized controlled trials and meta-analyses have also been reviewed. Side effects related to sexual function have also been mentioned briefly along with the efficacy and indication for robotic BPH surgery, which has recently been attracting attention. However, these newer, minimally invasive procedures require additional comparative randomized controlled trials and long-term results to produce more robust evidence for their use.
Aging
;
Anesthesia
;
Comorbidity
;
Humans
;
Korea
;
Lower Urinary Tract Symptoms
;
Methods
;
Minimally Invasive Surgical Procedures
;
Prevalence
;
Prostatic Hyperplasia
;
Sexual Dysfunction, Physiological
;
Transurethral Resection of Prostate
8.Influence of 0.2mg Tamsulosin Treatment on the Erectile and Ejaculatory Functions in Patients with Benign Prostatic Hyperplasia.
Sang Hoon SONG ; Hwancheol SON ; Jae Seung PAICK
Korean Journal of Urology 2007;48(12):1251-1257
PURPOSE: The aim of this study was to evaluate the influence of 8 weeks of 0.2mg tamsulosin medication on the erectile and ejaculatory functions of patients with benign prostatic hyperplasia(BPH). MATERIALS AND METHODS: 108 patients with BPH and they were without prostate cancer and neurogenic bladder were included in this study. Initial evaluations included a thorough history, digital rectal exam, urinalysis, serum prostate-specific antigen, uroflowmetry(UFM), post void residual urine measurement, transrectal ultrasound, International Prostatic Symptom Score(IPSS) and an International Index of Erectile Function(IIEF) and ejaculatory function questionnaire. After 4 and 8 weeks of medication, we analyzed the differences of these parameters at each week. RESULTS: The mean age of the patients was 61.3+/-9.0 years old and their prostate volume was 35.7+/-21.3ml. The IIEF erectile function(EF) domain score showed no statistically significant difference after medication. However, the orgasmic function domain score showed a significant decrease from 16.3+/-9.3 to 15.7+/-9.6 at the 4th and 8th week. Regarding the ejaculatory function, when the patients were divided into two groups according to the EF domain score(<10, > or =11), the score of the ejaculatory volume showed a tendency to decrease from 2.5+/-1.0 to 2.2+/-1.2(p=0.07), and the score for satisfaction about ejaculation was decreased from 3.0+/-1.2 to 2.5+/-1.5(p=0.01) in the larger EF domain group after 8 weeks of treatment. The IPSS score and UFM parameters improved significantly after medication(p<0.05). CONCLUSIONS: For the patients with BPH, 8 weeks of 0.2mg tamsulosin medication caused significant improvement in their voiding function. In addition, our findings suggest that 0.2mg tamsulosin medication may the influence erectile and ejaculatory function.
Ejaculation
;
Humans
;
Male
;
Orgasm
;
Prostate
;
Prostate-Specific Antigen
;
Prostatic Hyperplasia*
;
Prostatic Neoplasms
;
Questionnaires
;
Ultrasonography
;
Urinalysis
;
Urinary Bladder, Neurogenic
9.Psychometric Properties of the Korean Version of the Incontinence Quality of Life Instrument in Women with Stress Urinary Incontiennce.
Seung June OH ; Hwancheol SON ; Soo Woong KIM
Journal of the Korean Continence Society 2009;13(1):51-60
PURPOSE: To evaluate the psychometric properties of the Korean version of the Incontinence-Quality of Life (I-QOL) instrument in Korean women with symptoms of stress urinary incontinence. MATERIAL AND METHODS: Prospective study involving women with stress urinary incontince, who eventually underwent anti-incontinence surgery (n=89) was undertaken. Convergent and discriminant validity were assessed. Reliability was assessed by calculating Cronbach's alpha coefficient, and stability was assessed as well. Sensitivity to clinical change before and after operation was also evaluated. RESULTS: The Korean version of I-QOL proved to be not difficult to understand and acceptable to the patients. Significant association was found between the I-QoL scores and clinical parameters including overall symptom severity. The domain score were significantly different between control group and patient groups. Convergent validity of the I-QOL also proved adequate. Cronbach's alpha coefficients (>0.78) indicated reasonable internal consistency. Results from test-retest showed reproducible. I-QOL domains were generally responsive to clinical efficacy variables; the I-QOL also showed statistically significant sensitivity to changes in patients' perceptions of bladder condition in all domains. CONCLUSION: The Korean version of the I-QOL is valid and reliable for clinical use in Korean patients with stress urinary incontinence.
Female
;
Humans
;
Prospective Studies
;
Psychometrics*
;
Quality of Life*
;
Surveys and Questionnaires
;
Translations
;
Urinary Bladder
;
Urinary Incontinence
;
Urination
10.Initial Experiences with a New 120 W Greenlight(TM) High-Power System for Photoselective Vaporization of the Prostate for the Treatment of Benign Prostatic Hyperplasia in Korea.
Dong Woo KO ; Byong Chang JEONG ; Hwancheol SON
Korean Journal of Urology 2009;50(11):1089-1094
PURPOSE: After successful launches of a 120 W high-power system for photoselective vaporization of the prostate (HPS-PVP), several studies in the United States and Europe have reported good short-term data. Here we report the initial efficacy and side effects of the 120 W HPS-PVP in Korea. MATERIALS AND METHODS: Between January 2008 and January 2009, we performed a retrospective clinical analysis of 133 patients treated by HPS-PVP. RESULTS: The mean age at surgery was 68.4+/-8.0 years. The mean prostate size was 44.2+/-22.6 ml. The mean operation time was 58.9+/-33.5 minutes, and the mean total applied energy was 103,108+/-74,362 J. The mean duration of catheterization was 21.5+/-10.8 hours. The blood loss was minimal, and there were no transfusions. The baseline mean peak urinary flow rate (Qmax) was 10.4+/-5.0 ml/s, mean postvoid residual volume (PVR) was 77+/-91.3 ml, the mean International Prostate Symptom Score (IPSS) was 20.7+/-9.0, and the mean quality of life (QoL) score was 4.2+/-1.3. At 6 months, Qmax was 17.5+/-9.9 ml/sec, PVR was 49.0+/-56.0 ml, the IPSS was 8.0+/-9.0, and the QoL score was 1.6+/-1.5. During the first postoperative month, irritative urinary symptoms were reported in 18 cases, urge incontinence in 7, mild hematuria in 5, urinary tract infection in 2, and temporary recatheterization in 13. CONCLUSIONS: The new 120 W HPS-PVP showed good short-term safety and efficacy for the treatment of Korean patients with benign prostatic hyperplasia.
Catheterization
;
Catheters
;
Europe
;
Hematuria
;
Humans
;
Korea
;
Prostate
;
Prostatic Hyperplasia
;
Quality of Life
;
Residual Volume
;
Retrospective Studies
;
United States
;
Urinary Incontinence, Urge
;
Urinary Tract Infections
;
Volatilization