1.Risk Factors for Prolonged Postoperative Length of Stay After Hip Fracture Surgery in Very Elderly Patients.
Bo-Wen XU ; Wei-Yun CHEN ; Chen SUN ; Ling LAN ; Lu-Lu MA ; Li-Jian PEI
Chinese Medical Sciences Journal 2025;40(2):111-119
OBJECTIVES:
To identify risk factors contributing to prolonged postoperative length of stay (LOS) in very elderly patients following hip fracture surgery, with a focus on postoperative complications and the impact of different anesthesia approaches.
METHODS:
This retrospective single-center cohort study enrolled patients aged 90 years or older who underwent hip fracture surgery at Peking Union Medical College Hospital between January 31, 2013 and December 31, 2023. Relevant perioperative data were collected. The primary outcome was postoperative LOS, and the study cohort was divided into two groups: postoperative LOS ≤ 7 days and LOS > 7 days. Logistic regression was performed to identify factors related to prolonged postoperative LOS.
RESULTS:
A total of 155 patients were included. The average age was 92.7 ± 2.6 years. There were 73 (47%) patients with postoperative LOS > 7 days. Postoperative pneumonia was the only factor associated with a prolonged postoperative LOS (OR = 2.12, 95% CI [1.09, 4.16], P = 0.028). Neither the type of anesthesia (regional vs. general anesthesia, OR = 1.00, 95% CI [0.53, 1.90], P = 0.993) nor the method of airway management (laryngeal mask ventilation vs. spontaneous breathing, OR = 1.46, 95% CI [0.58, 3.76], P = 0.424; endotracheal intubation vs. spontaneous breathing, OR = 0.82, 95% CI [0.39, 1.69], P = 0.592) showed a significant association with a prolonged postoperative LOS. Preoperative chronic obstructive pulmonary disease (OR = 2.78, 95% CI [1.05, 7.65], P = 0.040) and preoperative neutrophil count (OR = 1.13, 95% CI [1.01, 1.26], P = 0.029) were both significantly associated with the occurrence of postoperative pneumonia, while anesthesia type and airway management method were not.
CONCLUSIONS
Postoperative pneumonia was associated with prolonged postoperative LOS in very elderly patients undergoing hip fracture surgery, whereas anesthesia types and airway management methods show no association with prolonged postoperative LOS or postoperative pneumonia. Preoperative comorbidities, especially respiratory conditions and systemic inflammation, potentially play a substantial role in postoperative recovery.
Humans
;
Hip Fractures/surgery*
;
Aged, 80 and over
;
Risk Factors
;
Length of Stay
;
Female
;
Male
;
Retrospective Studies
;
Postoperative Complications/etiology*
2.Postoperative Complications and 30-day Readmission in Patients Older than 80 Years with Chronic Kidney Disease after Hip Fracture.
Hua-Wen ZHANG ; Lu-Lu MA ; Xue-Rong YU
Chinese Medical Sciences Journal 2025;40(3):188-196
OBJECTIVES:
This study aimed to explore the impact of chronic kidney disease (CKD) on prognosis of patients older than 80 years after hip fracture.
METHODS:
This retrospective, observational, single-center study included patients older than 80 years who underwent hip fracture operations between Feburary 2013 to June 2021 at our hospital. Patients were divided into CKD and non-GKD groups based on the estimated glomerular filtration rate (eGFR) < 60 mL/(min·1.73m2)] or not. Outcomes were the incidence of in-hospital postoperative infectious and non-infectious complications, 30-day readmission, and in-hospital death. Logistic regression analysis was used to calculate the odds ratio (OR) of CKD on these outcomes.
RESULTS:
A total of 498 patients were included, 165 in the CKD group and 333 in the non-CKD group. Eighty-seven (52.7%) CKD patients experienced 140 episodes of postoperative complications. In comparison, 114 (34.2%) non-CKD patients had 158 episodes of postoperative complications. CKD patients were more likely to have postoperative complications than non-CKD patients (OR = 2.143, 95% CI: 1.465-3.134, P < 0.001). CKD increased the risk of cardiovascular complications (OR = 2.044, 95% CI: 1.245-3.356, P = 0.004), acute kidney injury (OR = 3.401, 95% CI: 1.905-6.072, P < 0.001), delirium (OR = 2.276, 95% CI: 1.140-4.543, P = 0.024), and gastrointestinal bleeding (OR = 4.151, 95% CI: 1.025-16.812, P = 0.031). The transfusion rate (OR = 2.457, 95% CI: 1.668-3.618, P < 0.001) and incidence of 30-day readmission (OR = 2.426, 95% CI:1.203-4.892, P = 0.011) in CKD patients were significantly higher than those in patients without CKD.
CONCLUSIONS
CKD is associated with poor postoperative outcomes in geriatric hip fracture patients. Special attention should be paid to patients with CKD.
Humans
;
Renal Insufficiency, Chronic/physiopathology*
;
Aged, 80 and over
;
Postoperative Complications/epidemiology*
;
Hip Fractures/complications*
;
Male
;
Female
;
Patient Readmission/statistics & numerical data*
;
Retrospective Studies
;
Glomerular Filtration Rate
3.Short-term effectiveness of Gamma 3 U-Blade system for osteoporotic intertrochanteric fractures in the elderly.
Wenbin FAN ; Liu SHI ; Tian XIE ; Cheng ZHANG ; Xiangxu CHEN ; Hui CHEN ; Yunfeng RUI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):47-52
OBJECTIVE:
To compare the short-term effectiveness between Gamma 3 intramedullary nails and Gamma 3 U-Blade system in the treatment of osteoporotic intertrochanteric fractures in the elderly.
METHODS:
A retrospective analysis was conducted on the clinical data of 124 elderly patients with osteoporotic intertrochanteric fractures, who were admitted between February 2020 and February 2023 and met the selection criteria. The fractures were fixed with Gamma 3 intramedullary nails in 65 patients (control group) and Gamma 3 U-Blade systems in 59 patients (UB group). The differences between the two groups were not significant in age, gender, body mass index, American Society of Anesthesiologists (ASA) classification, bone mineral density, time from injury to operation, fracture classification, and affected side ( P>0.05). The operation time, intraoperative blood loss, hospital stay, and fracture healing time were recorded; the tip-apex distance, fracture reduction quality, and lag screw position were evaluated on X-ray films at immediate after operation; the lag screw sliding distance and change value of neck-shaft angle were measured on X-ray films at last follow-up. Harris hip score at 1 year after operation and the occurrence of internal fixation-related complications were compared between the two groups.
RESULTS:
The operation time, intraoperative blood loss, and hospital stay in the UB group increased compared to the control group, but the differences were not significant ( P>0.05). All patients in both groups were followed up 12-24 months (mean, 17.1 months). At 12 months after operation, there was no significant difference in the Harris hip score between the two groups ( P<0.05). Radiological examination showed that there was no significant difference between the two groups ( P>0.05) in terms of tip-apex distance, fracture reduction quality, and lag screw position. Fractures healed in both groups, and there was no significant difference in healing time ( P>0.05). At last follow-up, the change value of neck-shaft angle and lag screw sliding distance in the UB group were significantly lower than those in the control group ( P<0.05). During follow-up, no related complications occurred in the UB group, while 6 cases (9.2%) in the control group experienced complications, and the difference in the incidence was significant ( P<0.05).
CONCLUSION
For the osteoporotic intertrochanteric fractures in the elderly, the Gamma 3 U-Blade system fixation can achieve good short-term effectiveness, with better imaging results compared to Gamma 3 intramedullary nails fixation.
Humans
;
Retrospective Studies
;
Hip Fractures/surgery*
;
Male
;
Female
;
Aged
;
Fracture Fixation, Intramedullary/methods*
;
Osteoporotic Fractures/surgery*
;
Bone Nails
;
Bone Screws
;
Aged, 80 and over
;
Treatment Outcome
;
Fracture Healing
;
Operative Time
;
Length of Stay
4.Treatment of irreducible intertrochanteric femoral fractures in elderly by novel bone hook combined with finger-guided technique.
Zenghui ZHANG ; Tichao HAN ; Wei LI ; Yangyang ZHOU ; Junjun LIU ; Nannan LI ; Tiantian REN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(1):53-58
OBJECTIVE:
To investigate the feasibility and effectiveness of the novel bone hook combined with finger-guided technique in the treatment of irreducible intertrochanteric femoral fractures in elderly.
METHODS:
Between January 2021 and August 2023, 23 elderly patients with irreducible intertrochanteric femoral fractures were treated with the novel bone hook combined with finger-guided technique. There were 10 males and 13 females; the age ranged from 68 to 93 years (mean, 76.2 years). The time from injury to operation ranged from 36 to 76 hours (mean, 51.2 hours). According to the classification standard proposed by TONG Dake et alin 2021, there were 10 cases of typeⅠA, 1 case of typeⅠB, 6 cases of type ⅡA, 4 cases of type ⅡB, and 2 cases of type ⅡC. The operation time, intraoperative blood loss, intraoperative fluoroscopy frequences, and quality of fracture reduction were recorded. The fracture healing time and occurrence of postoperative complications were observed during follow-up. At last follow-up, the Harris scoring system was used to evaluate the hip joint function.
RESULTS:
The operation time was 42-95 minutes (mean, 52.1 minutes). The intraoperative blood loss was 40-420 mL (mean, 126.5 mL). Intraoperative fluoroscopy was performed 14-34 times (mean, 20.7 times). According to the criteria proposed by Chang et al, the quality of fracture reduction was rated as good in 20 cases and acceptable in 3 cases. All patients were followed up 6-20 months (mean, 10.2 months). X-ray film showed that all fractures healed with the healing time of 3.0-5.5 months (mean, 4.0 months). At last follow-up, the Harris score of the hip joint ranged from 82 to 97 points (mean, 90.4 points). Among them, 14 cases were rated as excellent and 9 cases as good. No complication such as coxa vara, cutting of the cephalomedullary nail, nail withdrawal, or nail breakage occurred during follow-up.
CONCLUSION
The treatment of elderly patients with irreducible intertrochanteric femoral fractures by using the novel bone hook combined with finger-guided technique can achieve high-quality fracture reduction and fixation, and has a good effectiveness.
Humans
;
Male
;
Female
;
Aged
;
Aged, 80 and over
;
Hip Fractures/diagnostic imaging*
;
Fracture Fixation, Internal/instrumentation*
;
Fracture Healing
;
Treatment Outcome
;
Operative Time
;
Fracture Fixation, Intramedullary/instrumentation*
;
Bone Nails
;
Postoperative Complications/epidemiology*
;
Feasibility Studies
;
Fingers
5.Study on assessment methods for acetabular cup size in total hip arthroplasty.
Jinzi WANG ; Wenju CHANG ; Pei ZHANG ; Xiang LI ; Yong ZHANG ; Shuoshuo ZHANG ; Hai DING
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(2):163-167
OBJECTIVE:
To evaluate precise assessment methods for predicting the optimal acetabular cup size in total hip arthroplasty (THA).
METHODS:
A clinical data of 73 patients (80 hips) who underwent primary THA between December 2022 and July 2024 and met the inclusion criteria was analyzed. There were 39 males and 34 females with an average age of 66.3 years (range, 56-78 years). Among them, 66 cases were unilateral THA and 7 were bilateral THAs. There were 29 patients (34 hips) of osteoarthritis, 35 patients (35 hips) of femoral neck fractures, and 9 patients (11 hips) of osteonecrosis of the femoral head. Based on anteroposterior pelvic X-ray films, three methods were employed to predict acetabular cup size, including preoperative template planning, radiographic femoral head diameter (FHD) measurement, and intraoperative FHD measurement. The predicted acetabular cup sizes from these methods were compared with the actual implanted sizes.
RESULTS:
The predicted acetabular cup sizes using the preoperative template planning, radiographic FHD measurement, and intraoperative FHD measurement were (51.25±2.81), (49.72±3.11), and (49.90±2.74) mm, respectively, compared to the actual implanted cup size of (50.57±2.74) mm, with no significant difference ( P>0.05). Regarding agreement with the actual implanted cup size, the preoperative template planning achieved exact matches in 35 hips (43.75%), one-size deviation in 41 hips (51.25%), and two-size deviations in 4 hips (5%); the radiographic FHD measurement achieved exact matches in 12 hips (15%), one-size deviation in 57 hips (71.25%), and two-size deviations in 11 hips (13.75%); and the intraoperative FHD measurement achieved exact matches in 26 hips (32.5%), one-size deviation in 52 hips (65%), and two-size deviations in 2 hips (2.5%). There were significant differences in agreement distributions between the three methods and the actual implanted cup sizes ( H=18.579, P<0.001).
CONCLUSION
The intraoperative FHD measurement, as a simple, cost-effective, and accurate method, effectively guides acetabular cup selection, reduces the risk of prosthesis wear, enhances postoperative joint stability.
Humans
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Male
;
Female
;
Middle Aged
;
Acetabulum/diagnostic imaging*
;
Aged
;
Hip Prosthesis
;
Prosthesis Design
;
Femur Head/surgery*
;
Osteoarthritis, Hip/surgery*
;
Radiography
;
Femoral Neck Fractures/surgery*
;
Femur Head Necrosis/surgery*
6.Effectiveness of guide plate with mortise-tenon joint structure combined with off-axis fixation in treatment of Pauwels type Ⅲ femoral neck fractures.
Xuanye ZHU ; Lijuan CUI ; Leilei ZHANG ; Yudong JIA ; Yingjie ZHU ; Youwen LIU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(3):284-289
OBJECTIVE:
To investigate the effectiveness of using 3 hollow compression screws combined with 1 screw off-axis fixation under the guidance of three-dimensional (3D) printed guide plate with mortise-tenon joint structure (mortise-tenon joint plate) for the treatment of Pauwels type Ⅲ femoral neck fractures.
METHODS:
A clinical data of 78 patients with Pauwels type Ⅲ femoral neck fractures, who were admitted between August 2022 and August 2023 and met the selection criteria, was retrospectively analyzed. The operations were assisted with mortise-tenon joint plates in 26 cases (mortise-tenon joint plate group) and traditional guide plates in 28 cases (traditional plate group), and without guide plates in 24 cases (control group). There was no significant difference in the baseline data of gender, age, body mass index, cause of injury, and fracture side between groups ( P>0.05). The operation time, intraoperative blood loss, frequency of intraoperative fluoroscopy, incision length, incidence of postoperative deep vein thrombosis of lower extremity, pain visual analogue scale (VAS) score at 1 week after operation, and Harris score of hip joint at 3 months after operation were recorded and compared. X-ray re-examination was taken to check the quality of fracture reduction, fracture healing, and the shortening length of the femoral neck at 3 months after operation, and the incidences of internal fixation failure and osteonecrosis of the femoral head during operation.
RESULTS:
Compared with the control group, the operation time, intraoperative blood loss, and frequency of intraoperative fluoroscopy reduced in the two plate groups, and the quality of fracture reduction was better, but the incision was longer, and the differences were significant ( P<0.05). The operation time and intraoperative blood loss were significantly higher in the traditional plate group than in the mortise-tenon joint plate group ( P<0.05), the incision was significantly longer ( P<0.05); and the difference in fracture reduction quality and the frequency of intraoperative fluoroscopy was not significant between two plate groups ( P>0.05). There was 1 case of deep vein thrombosis of lower extremity in the traditional plate group and 1 case in the control group, while there was no thrombosis in the mortise-tenon joint plate group. There was no significant difference in the incidence between groups ( P>0.05). All patients were followed up 12-15 months (mean, 13 months). There was no significant difference in VAS score at 1 week and Harris score at 3 months between groups ( P>0.05). Compared with the control group, the fracture healing time and the length of femoral neck shortening at 3 months after operation were significantly shorter in the two plate groups ( P<0.05). There was no significant difference between the two plate groups ( P>0.05). There was no significant difference in the incidences of non-union fractures, osteonecrosis of the femoral head, or internal fixation failure between groups ( P>0.05).
CONCLUSION
For Pauwels type Ⅲ femoral neck fractures, the use of 3D printed guide plate assisted reduction and fixation can shorten the fracture healing time, reduce the incidence of postoperative complications, and be more conducive to the early functional exercise of the affected limb. Compared with the traditional guide plate, the mortise-tenon joint plate can reduce the intraoperative bleeding and shorten the operation time.
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Plates
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Retrospective Studies
;
Middle Aged
;
Bone Screws
;
Adult
;
Aged
;
Treatment Outcome
;
Printing, Three-Dimensional
;
Operative Time
7.Treatment of irreducible intertrochanteric femoral fracture in elderly with proximal femoral nail antirotation combined with minimally invasive clamp reduction technique by Kocher pincers.
Hongwei TANG ; Yong YIN ; Yinhua MA
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):536-541
OBJECTIVE:
To explore the effectiveness of proximal femoral nail antirotation (PFNA) combined with minimally invasive clamp reduction technique by Kocher pincers in the treatment of irreducible intertrochanteric femoral fracture in the elderly.
METHODS:
The clinical data of 35 elderly patients with irreducible intertrochanteric femoral fractures who were treated with PFNA combined with minimally invasive clamp reduction technique by Kocher pincers between January 2016 and December 2022 were retrospectively analysed. There were 16 males and 19 females, aged from 63 to 95 years (mean, 75.2 years). The causes of injury included traffic accident in 3 cases and falling in 32 cases. The time from injury to operation was 2-11 days (mean, 3.6 days). According to AO/Orthopaedic Trauma Association (AO/OTA) classification system for intertrochanteric fractures, there were 14 cases of type A1, 18 cases of type A2, and 3 cases of type A3. According to the displacement of fracture by intraoperative fluoroscopy, there were 5 cases with only coronal displacement, 17 cases with only sagittal displacement, and 13 cases with both coronal and sagittal displacement. The operation time, intraoperative blood loss, rate of hemoglobin decline at 1 day after operation, length of hospital stay, and fracture healing time were recorded. The reduction quality of fracture during operation was evaluated according to reduction quality criteria proposed by Chang et al. The Harris scoring system was used to evaluate the hip joint function at last follow-up.
RESULTS:
The operation time was 45-105 minutes (mean, 54.4 minutes); the intraoperative blood loss was 80-300 mL (mean, 116.3 mL). The reduction quality of fracture during operation was good in 22 cases (62.9%) and acceptable in 13 cases (37.1%). The rate of hemoglobin decline at 1 day after operation ranged from 6.2% to 18.6% (mean, 10.2%); the length of hospital stay was 5-18 days (mean, 7.2 days). One case died of respiratory failure due to pulmonary infection, 2 cases were lost to follow-up, and the remaining 32 cases were followed up 6-24 months (mean, 10.6 months). All 32 patients achieved bony union and the healing time was 3-9 months (mean, 3.6 months). There was no complication such as incision infection, internal fixation failure, or coxa varus during follow-up. At last follow-up, the Harris score of hip joint was 67-96 (mean, 88.9); among them, 19 cases were excellent, 10 cases were good, 2 cases were fair, and 1 case was poor, with an excellent and good rate of 90.6%.
CONCLUSION
For the elderly patients with irreducible intertrochanteric femoral fracture, the application of PFNA combined with minimally invasive clamp reduction technique by Kocher pincers can achieve high-quality fracture reduction, which has the advantages of simple reduction operation, less trauma, and can avoid the radiation exposure of operators during maintenance reduction.
Humans
;
Male
;
Female
;
Aged
;
Minimally Invasive Surgical Procedures/methods*
;
Hip Fractures/diagnostic imaging*
;
Bone Nails
;
Aged, 80 and over
;
Retrospective Studies
;
Fracture Fixation, Intramedullary/instrumentation*
;
Middle Aged
;
Treatment Outcome
;
Fracture Fixation, Internal/instrumentation*
;
Fracture Healing
;
Femoral Fractures/surgery*
8.Finite element analysis of adding one transverse screw for Pauwels type Ⅲ femoral neck fractures.
Luyao MA ; Xueao SUN ; Qingjun TAN ; Yanping LAN ; Xiaohu WANG ; Yunsheng YIN ; Jinhui MA
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):584-591
OBJECTIVE:
To investigate whether adding 1 transverse screw (TS) to the triangular parallel cannulated screw (TPCS) fixation has a mechanical stability advantage for Pauwels type Ⅲ femoral neck fractures by conducting finite element analysis on four internal fixation methods.
METHODS:
Based on CT data of a healthy adult male volunteer's femur, three Pauwels type Ⅲ femoral neck fracture models (Pauwels angle 70°, Pauwels angle 80°, and Pauwels angle 70° combined with bone defect) were constructed using Mimics 21.0 software and SolidWorks 2017 software. Four different internal fixation models were built at the same time, including TPCS, TPCS+TS, three cross screws (TCS), and TPCS+medial buttress plate (MBP). The mechanical stability of different models under the same load was compared by finite element analysis.
RESULTS:
The femoral model established in this study exhibited a maximum stress of 28.62 MPa, with relatively higher stress concentrated in the femoral neck. These findings were comparable to previous studies, indicating that the constructed femoral finite element model was correct. The maximum stress of internal fixation in finite element analysis showed that TCS was the lowest and TPCS+MBP was the highest in Pauwels angle 70° and 80° models, while TPCS+TS was the lowest and TCS was the highest in Pauwels angle 70° combined with bone defect model. The maximum displacement of internal fixation in each fracture model was located at the top of the femoral head, with TCS having the highest maximum displacement of the femur. The maximum stress of fracture surface in finite element analysis showed that TCS was the lowest and TPCS was the highest in the Pauwels angle 70° model, while TPCS+MBP was the lowest and TPCS/TCS were the highest in the Pauwels angle 80° model and the Pauwels angle 70° combined with bone defect model, respectively. The maximum displacement of fracture surfece analysis showed that TPCS+MBP was the lowest and TCS was the highest in Pauwels angle 70° and 80° models, while TPCS+TS was the lowest and TCS was the highest in Pauwels angle 70° combined with bone defect model.
CONCLUSION
For Pauwels type Ⅲ femoral neck fractures, the biomechanical stability of TPCS+TS was superior to that of TPCS alone and TCS, but it has not yet reached the level of TPCS+MBP.
Finite Element Analysis
;
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Screws
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Bone Plates
;
Stress, Mechanical
;
Biomechanical Phenomena
;
Tomography, X-Ray Computed
;
Adult
;
Femur Neck/surgery*
9.Analysis of effectiveness of Holosight robot navigation-assisted percutaneous cannulated screw fixation in treatment of femoral neck fractures.
Weizhen XU ; Zhenqi DING ; Hui LIU ; Jinhui ZHANG ; Yuanfei XIONG ; Jin WU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):673-679
OBJECTIVE:
To investigate the effectiveness of Holosight robotic navigation-assisted percutaneous cannulated screw fixation for femoral neck fractures.
METHODS:
A retrospective analysis was conducted on 65 patients with femoral neck fractures treated with cannulated screw fixation between January 2022 and February 2024. Among them, 31 patients underwent robotic navigation-assisted screw placement (navigation group), while 34 underwent conventional freehand percutaneous screw fixation (freehand group). Baseline characteristics, including age, gender, fracture side, injury mechanism, Garden classification, Pauwels classification, and time from injury to operation, showed no significant differences between the two groups ( P>0.05). The operation time, intraoperative blood loss, fluoroscopy frequency, fracture healing time, and complications were recorded and compared, and hip function was evaluated by Harris score at last follow-up. Postoperative anteroposterior and lateral hip X-ray films were taken to assess screw distribution accuracy, including deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex.
RESULTS:
No significant difference was observed in operation time between the two groups ( P>0.05). However, the navigation group demonstrated superior outcomes in intraoperative blood loss, fluoroscopy frequency, deviation from the femoral neck axis, inter-screw parallelism, and distance from screws to the femoral neck cortex ( P<0.05). No incision infections or deep vein thrombosis occurred. All patients were followed up 12-18 months (mean, 16 months). In the freehand group, 1 case suffered from cannulated screw dislodgement and nonunion secondary to osteonecrosis of femoral head at 1 year after operation, 1 case suffered from screw penetration secondary to osteonecrosis of femoral head at 5 months after operation; and 1 case suffered from nonunion secondary to osteonecrosis of femoral head at 6 months after operation in the navigation group. All the 3 patients underwent internal fixators removal and total hip arthroplasty. There was no significant difference in the incidence of complications between the two groups ( P>0.05). The fracture healing time and hip Harris score at last follow-up in the navigation group were significantly better than those in the freehand group ( P<0.05).
CONCLUSION
Compared to freehand percutaneous screw fixation, Holosight robotic navigation-assisted cannulated screw fixation for femoral neck fractures achieves higher precision, reduced intraoperative radiation exposure, smaller incisions, and superior postoperative hip function recovery.
Humans
;
Femoral Neck Fractures/diagnostic imaging*
;
Bone Screws
;
Fracture Fixation, Internal/instrumentation*
;
Male
;
Female
;
Retrospective Studies
;
Robotic Surgical Procedures/methods*
;
Middle Aged
;
Aged
;
Adult
;
Treatment Outcome
;
Operative Time
;
Fracture Healing
;
Surgery, Computer-Assisted/methods*
;
Fluoroscopy
10.Application of precise-guided temporary fixation assistive devices in proximal femoral nail antirotation fixation for femoral intertrochanteric fractures.
Wanming QU ; Hongbin ZHOU ; Xiangwei ZHANG ; Qinghua XIANG ; Wenbin SHEN ; Xin YU ; Wenyao CHEN ; Xinzhi LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):680-685
OBJECTIVE:
To investigate the feasibility and effectiveness of precise-guided temporary fixation assistive devices in assisting the main nail guide pin placement and precise temporary fixation in proximal femoral nail antirotation (PFNA) internal fixation of femoral intertrochanteric fractures.
METHODS:
A prospective randomized controlled study was conducted to analyze the clinical data of 60 patients with femoral intertrochanteric fractures over 65 years old who met the selection criteria between January 2020 and June 2022 and were treated with PFNA internal fixation. The patients were randomly divided into the trial group (auxiliary device guided main nail guide pin placement and temporary fixation) and the control group (conventional treatment), with 30 cases in each group. There was no significant difference in baseline data such as gender, age, cause of injury, time from injury to operation, fracture side, AO/Orthopaedic Trauma Association (AO/OTA) classification, and combined medical diseases between the two groups ( P>0.05). The operation time, times of main nail guide pin placement, intraoperative fluoroscopy frequency, intraoperative blood loss, and perioperative blood transfusion were recorded and compared between the two groups. The quality of fracture reduction was evaluated by CHANG Shimin et al criteria. Harris score was used to evaluate the hip function at 1 year after operation.
RESULTS:
In the trial group, 2 temporary fixation needles were successfully placed 2-5 times, including 2 times in 13 cases (43.3%), 3 times in 8 cases (26.7%), 4 times in 7 cases (23.3%), and 5 times in 2 cases (6.7%). The operation time, times of main nail guide pin placement, intraoperative fluoroscopy frequency, and intraoperative blood loss in the trial group were significantly less than those in the control group, and the reduction quality score was significantly better than that in the control group ( P<0.05). There was no significant difference in perioperative blood transfusion between the two groups ( P>0.05). All patients were followed up 12-19 months (mean, 15 months). There was no complication such as incision infection, deep vein thrombosis, or internal fixation loosening. At 1 year after operation, the Harris score of the affected hip joint in the trial group was significantly higher than that in the control group ( P<0.05).
CONCLUSION
The technique of main nail guide pin placement and temporary fixation under the guidance of auxiliary devices in PFNA internal fixation can achieve faster insertion of the main nail guide pin, accurate temporary fixation to maintain reduction, and avoid the subsequent operation space, so as to improve the effectiveness.
Humans
;
Bone Nails
;
Male
;
Female
;
Hip Fractures/surgery*
;
Fracture Fixation, Intramedullary/instrumentation*
;
Aged
;
Prospective Studies
;
Operative Time
;
Treatment Outcome
;
Fracture Fixation, Internal/instrumentation*
;
Aged, 80 and over

Result Analysis
Print
Save
E-mail