1.Anteromedial cortical support reduction in treatment of trochanteric femur fractures: a ten-year reappraisal.
Sunjun HU ; Shouchao DU ; Shimin CHANG ; Wei MAO ; Zhenhai WANG ; Kewei TIAN ; Tao LIU ; Yunfeng RUI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1501-1509
OBJECTIVE:
This review summarized the first 10-year progresses and controversies in the concept of anteromedial cortical support reduction, to provide references for further study and clinical applications.
METHODS:
Relevant domestic and foreign literature on cortical support reduction was extensively reviewed to summarize the definition of positive, neutral, and negative support, anteromedial cortices at the inferior corner, intraoperative technical tips for fracture reduction, radiographic assessment at different periods, comparison between positive versus neutral and medial versus anterior support, and the clinical efficacy of Chang reduction quality criteria (CRQC) and postoperative stability score.
RESULTS:
Anteromedial cortical support reduction was only focused on the cortex of anteromedial inferior corner, with no concern the status of lateral wall or lesser trochanter. Anteromedial cortex was seldom involved by fracture comminution, it was thicker, denser, and stronger, and was the key for mechanical buttress of the head-neck fragment to share compression load. Positive, neutral, and negative support were also called "extramedullary, anatomic, and intramedullary reduction", respectively. There was hardly seen parallel cortical apposition, but characterized by some kinds of head-neck rotation, for example 10°-15° flexed rotation for positive cortical contact and support. Due to intraoperative compression and postoperative impaction, the status of cortical support may be changed at different time of radiographic examination. The positive medial cortex support was more reliable with less reduction loss than its neutral counterpart, and the anterior cortex contact was more predictive than the medial cortex for final results. As incorporation the bearing of cortex apposition and using a 4-point score, CRQC demonstrated more efficacy and was gradually accepted and applied in the evaluation of trochanteric fracture reduction quality. Postoperative stability score (8 points) provided a assessment tool for early weight-bearing in safety to prevent mechanical failure.
CONCLUSION
Anteromedial cortical support reduction is a key point for stability reconstruction in the treatment of trochanteric femur fractures. Evidence has definitely shown that non-negative (positive and neutral) is superior to negative (loss of cortical support). There is a tendency that positive cortex support is superior to neutral, but high quality study with large sample size is needed for a clear conclusion.
Humans
;
Femur/diagnostic imaging*
;
Fracture Fixation, Internal/methods*
;
Hip Fractures/diagnostic imaging*
;
Treatment Outcome
;
Fracture Fixation, Intramedullary/methods*
2.Early follow-up study on three-dimensional-printed customized porous acetabular components for reconstructing extensive acetabular bone defects in primary total hip arthroplasty.
Shangkun TANG ; Zhuangzhuang LI ; Xin HU ; Linyun TAN ; Hao WANG ; Yitian WANG ; Minxun LU ; Fan TANG ; Yi LUO ; Yong ZHOU ; Chongqi TU ; Li MIN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1543-1550
OBJECTIVE:
To evaluate the feasibility and short-term effectiveness of three-dimensional (3D)-printed customized porous acetabular components for reconstruction of extensive acetabular bone defects during primary total hip arthroplasty (THA).
METHODS:
The clinical data of 8 patients with extensive acetabular bone defects, who were treated with 3D-printed individualized porous acetabular components between July 2018 and January 2022, were retrospectively analyzed. The cohort comprised 4 males and 4 females with an average age of 48 years ranging from 34 to 56 years. Acetabular bone defects were classified as Paprosky type ⅢA in 3 cases and type ⅢB in 5 cases. The causes of acetabular destruction were hip tuberculosis (5 cases), pigmented villonodular synovitis (2 cases), and syphilitic arthritis (1 case). Visual analogue scale (VAS) score and Harris hip score (HHS) were used to evaluate the pain relief and hip function before and after operation. Reconstruction outcomes were further assessed by imaging results [X-ray film and Tomosynthesis Shimadzumetal artefact reduction technology (T-SMART)], and the mechanical properties were evaluated by finite element analysis.
RESULTS:
The operation time ranged from 174 to 195 minutes (mean, 187 minutes), and intraoperative blood loss ranged from 390 to 530 mL (mean, 465 mL). All 8 patients were follow-up 26-74 months (mean, 44 months). Among the 5 patients with tuberculosis, none experienced postoperative recurrence. At last follow-up, the VAS score was 0.3±0.5 and the HHS score was 87.9±3.7, both significantly improved compared to preoperative values ( t=25.170, P<0.001; t=-28.322, P<0.001). X-ray films at 2 years after operation demonstrated satisfactory matching between the 3D-printed customized acetabular component and the acetabulum. The postoperative center of rotation of the operated hip was shifted by (2.1±0.5) mm horizontally and (2.0±0.7) mm vertically relative to the contralateral side, with both offsets showing significant differences compared to preoperative values ( t=24.700, P<0.001; t=55.230, P<0.001). T-SMART imaging showed satisfactory osseointegration at the implant-host bone interface. No complications such as aseptic loosening or screw breakage was observed during follow-up. Finite element analysis showed that the acetabular component had good mechanical properties.
CONCLUSION
The application of 3D-printed individualized porous acetabular components in the reconstruction of extensive acetabular bone defects demonstrated precise anatomical reconstruction, stable mechanical support, and good functional performance in short-term follow-up, offering a potential alternative for acetabular defect reconstruction in primary THA.
Humans
;
Middle Aged
;
Male
;
Female
;
Printing, Three-Dimensional
;
Arthroplasty, Replacement, Hip/instrumentation*
;
Acetabulum/diagnostic imaging*
;
Adult
;
Follow-Up Studies
;
Retrospective Studies
;
Hip Prosthesis
;
Prosthesis Design
;
Porosity
;
Treatment Outcome
;
Plastic Surgery Procedures/methods*
3.Effectiveness of arthroscopic treatment for femoroacetabular impingement syndrome combined with ligamentum teres injury.
Siyu HAN ; Song LI ; Di JIA ; Yanlin LI ; Guofeng CAI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1551-1555
OBJECTIVE:
To investigate the effectiveness of hip arthroscopy in the treatment of patients with femoroacetabular impingement (FAI) syndrome combined with ligamentum teres injury.
METHODS:
A retrospective analysis was conducted on 23 patients (23 hips) with Cam-type FAI syndrome combined with ligamentum teres injury who met the selection criteria between April 2022 and May 2024. The cohort included 12 males and 11 females, with a mean age of 29.16 years (range, 16-57 years). According to Tönnis classification, there were 5 cases of grade 0, 10 cases of grade Ⅰ, and 8 cases of grade Ⅱ in hip osteoarthritis. The disease duration ranged from 6 to 24 months, with an average of 12 months. Under hip arthroscopy, hypertrophic synovium and the damaged ligamentum teres were debrided, while the torn labrum and cartilage were repaired, and femoral head-neck osteoplasty was performed to eliminate impingement, restore the normal morphology of the acetabulum and femoral head-neck, and suture the joint capsule. Acetabular lateral center-edge angle (LCEA) and α angle (reflecting the degree of non-sphericity at the femoral head-neck junction) were measured before and after operation, and the modified Harris hip score (mHHS), the International Hip Outcome Tool-12 (IHOT-12), and the visual analogue scale (VAS) score for pain were evaluated.
RESULTS:
The operation was successfully completed in all patients. The incisions healed by first intention after operation, and there was no perioperative complications such as iatrogenic cartilage injury, fracture, infection, neurovascular traction injury, or lower extremity venous thrombosis. All the 23 patients were followed up 12-24 months, with an average of 14.6 months. The pain of hip joint significantly relieved, and the function of hip joint improved; no complication such as joint stiffness, joint instability, and osteonecrosis of the femoral head occurred. The α angle, VAS score, mHHS score, and IHOT-12 score at last follow-up were significantly better than those before operation ( P<0.05); there was no significant difference in LCEA compared to preoperative value ( P>0.05).
CONCLUSION
Hip arthroscopy is a safe and effective treatment for patients with FAI syndrome combined with ligamentum teres injury, which can achieve satisfactory effectiveness.
Humans
;
Femoracetabular Impingement/complications*
;
Arthroscopy/methods*
;
Adult
;
Male
;
Female
;
Retrospective Studies
;
Middle Aged
;
Adolescent
;
Treatment Outcome
;
Young Adult
;
Hip Joint/surgery*
;
Acetabulum/surgery*
;
Round Ligaments/surgery*
;
Range of Motion, Articular
4.Preoperative diagnostic efficacy of novel blood markers white blood cell ratio and fibrinogen levels in periprosthetic joint infection.
Geng-Yao ZHU ; Chao MA ; Guang-Wang LIU ; Jia-Zheng MAN
China Journal of Orthopaedics and Traumatology 2025;38(1):55-60
OBJECTIVE:
To investigate the clinical utility of novel of new hematological markers in the preoperative diagnosis of periprosthetic joint infection (PJI).
METHODS:
A retrospective analysis was conducted on a total of 149 patients who underwent revision of total hip arthroplasty (THA) or total knee arthroplasty (TKA) at a single center between January 2016 and June 2022, including 63 males and 86 females, aged from 47 to 93 years old with an average of (69.5±11.8) years old. Of them, 46 were diagnosed as PJI(PJI group), including 22 males and 24 females. The mean age was (71.3±12.5) years old. The body mass index (BMI) was (26.4±3.1) kg·m-2. And 103 patients were diagnosed as aseptic prosthesis loosening (aseptic group), including 41 males and 62 females. The mean age was (68.7±11.4) years old. The BMI was (25.8±3.5) kg·m-2. Preoperatively analyzed clinical parameters included C-reactive protein (CRP), erythrocyte sedimentation rate (ESR), albumin, globulin, albumin-to-globulin ratio (AGR), plasma D-dimer, and plasma fibrinogen. The receiver operating characteristic curve (ROC), sensitivity, and specificity analysis were employed to compare the diagnostic value of each blood marker in preoperative PJI diagnosis.
RESULTS:
In the PJI group, the levels of CRP were 16.6 (7.6, 4.5) mg·L-1, ESR was 17.0 (12.8, 35.5) mm·h-1, plasma D-dimer was 1.0 (0.5, 3.1) μg·L-1, and plasma fibrinogen was 4.2 (3.2, 3.1) mg·L-1;all of which were higher compared to the aseptic group with CRP at 4.2 (2.6, 7.8) mg·L-1, ESR at 12.0(8.0, 20.0 )mm·h-l, D-dimer at 0.4(0.2, 0.7)μg·L-1, and fibrinogen at 2.8(2.4, 3.3 ) g·L-1(P<0.05). However, the albumin level of 35.3 (32.3, 37.5) g·L-1 and the WBC ratio of 1.0(0.9, 1.1) in the PJI group were significantly lower compared to the aseptic group with levels of 39.8 (36.1, 41.8) g·L-1 and 1.4 (1.3, 1.5), respectively (P<0.05). Only the area under the curve (AUC) of AGR and plasma fibrinogen were greater than 0.8. The optimal predictive cut-1off, AUC, sensitivity and specificity were 3.4 g·L-1, 0.820, 69.57% and 84.47% for plasma fibrinogen; 1.18, 0.813, 82.61% and 78.64% for AGR, respectively.
CONCLUSION
AGR and plasma fibrinogen are promising blood markers for improving the diagnosis of PJI.
Humans
;
Female
;
Fibrinogen/metabolism*
;
Male
;
Middle Aged
;
Aged
;
Prosthesis-Related Infections/blood*
;
Retrospective Studies
;
Biomarkers/blood*
;
Aged, 80 and over
;
Arthroplasty, Replacement, Knee/adverse effects*
;
Arthroplasty, Replacement, Hip/adverse effects*
;
Leukocyte Count
5.Risk factors for cutout failure in geriatric intertrochanteric fracture patients after cephalomedullary nail fixation.
You-Liang HAO ; Fang ZHOU ; Hong-Quan JI ; Yun TIAN ; Zhi-Shan ZHANG ; Yan GUO ; Yang LYU ; Zhong-Wei YANG ; Guo-Jin HOU
China Journal of Orthopaedics and Traumatology 2025;38(2):141-147
OBJECTIVE:
To determine risk factors for cutout failure in geriatric intertrochanteric fracture patients after cephalomedullary nail fixation.
METHODS:
A retrospective review of 518 elderly patients who underwent cephalomedullary nail fixation for intertrochanteric fractures between January 2008 and August 2018 was conducted, including 167 males and 351 females, age from 65 to 97 years old. All patients were followed up for at least one year after surgery and divided into a healed group and a cutout group based on whether the hip screw cutout occurred. Among all patients, 10 cases experienced hip screw cutout. The general information, surgical data, and radiological data of the two groups were compared, and risk factors influencing hip screw cutout were analyzed. Propensity score matching was then performed on the cutout group based on gender, age, body mass index(BMI), and American Society of Anesthesiologists(ASA), and 40 patients from the healed group were matched at a ratio of 1∶4. Key risk factors affecting hip screw cutout were further analyzed. Multivariable logistic regression analysis was conducted to evaluate associations between variables and cutout failure.
RESULTS:
There were no statistically significant differences between the healed group and the cutout group in terms of age, gender, BMI, ASA, and AO classification. However, statistically significant differences were observed between the two groups in terms of reduction quality(P=0.003) and tip-apex distance(TAD), P<0.001. Multivariate analysis identified poor reduction quality OR=23.138, 95%CI(2.163, 247.551), P=0.009 and TAD≥25 mm OR=30.538, 95%CI(2.935, 317.770), P=0.004 as independent risk factors for cutout failure.
CONCLUSION
The present study identified poor reduction quality and TAD≥25 mm as factors for cutout failure in geriatric intertrochanteric fractures treated with cephalomedullary nails. Further studies are needed to calculate the optimal TAD for cephalomedullary nails.
Humans
;
Male
;
Female
;
Hip Fractures/surgery*
;
Aged, 80 and over
;
Aged
;
Risk Factors
;
Retrospective Studies
;
Fracture Fixation, Intramedullary/adverse effects*
;
Bone Nails
;
Bone Screws
6.Early clinical outcomes of 3D-printed individualised customised prostheses in hip revision combined severe bone defect.
Hong-Ping WANG ; Ming-You WANG ; Xiao-Qin YANG ; Zhuo-Dong TANG ; Xun-Zhou SONG ; Yu-Ping LAN
China Journal of Orthopaedics and Traumatology 2025;38(2):163-169
OBJECTIVE:
To explore the early clinical outcomes of 3D printed individualised customised prostheses for in hip revision in patients with combined severe bone defects.
METHODS:
Twenty-two patients from January 2021 to May 2023 underwent hip revision using 3D printed personalised customised prostheses were retrospective analyzed, including 10 males and 12 females, age 28 to 78 with a mean of (58.9±12.8) years old. All of patients were combined with severe bone defects (Parprosky type Ⅲ). Among of them, 9 patients had periprosthetic infections and 13 patients had aseptic prosthesis loosening. All patients were treated with a 3D printed personalised prosthesis protocol, patients with the periprosthetic infection received a second stage revision after infection control. The operation time, preoperative waiting time, intraoperative and postoperative complications were recorded, and the clinical efficacy were evaluated at the final follow-up using the visual analogue scale (VAS) for pain, the Harris hip score.
RESULTS:
One patient was lost to follow-up and the remaining 21 patients were followed up for 10 to 15 with a mean of (12.91±1.44) months after surgery. All patients completed surgery as planned, with an operative time of 135 to 390 with a mean of (165.4±39.3) minutes and a preoperative waiting time of 7 to 16 with a mean of (10.5±3.3) days. Regarding patient complications:one patient had a severe intraoperative periprosthetic femoral fracture due to the combination of severe osteoporosis; one patient had an intraoperative greater trochanteric femur fracture. At the latest follow-up, all patients had good position of the custom-made prosthesis and no loosening of the prosthesis;all patients had good wound healing and no local redness or swelling. The total Harris score at the final follow-up (85.86±7.04) was significantly improved compared to the preoperative (44.86±2.36), P<0.001. The VAS at the last follow-up (2.19±0.87) was significantly improved compared with preoperative (7.41±0.96), P<0.001.
CONCLUSION
The clinical efficacy of 3D-printed personalised customised prosthesis in combined severe bone defect hip revision is satisfactory, but due to the increased preoperative waiting time of the patients and certain risks, certain indications should be mastered when applying in the clinic.
Humans
;
Male
;
Female
;
Printing, Three-Dimensional
;
Middle Aged
;
Aged
;
Adult
;
Retrospective Studies
;
Hip Prosthesis
;
Arthroplasty, Replacement, Hip
;
Reoperation
;
Prosthesis Design
;
Treatment Outcome
7.Application of grid locator in hip arthroscopy for the treatment of femoroacetabular impingement features.
Kun-Yang XIA ; Wen-Li RUAN ; Shou-Yun WANG ; Jin-Xian YANG
China Journal of Orthopaedics and Traumatology 2025;38(2):176-182
OBJECTIVE:
To explore the application effect of grid locator in hip arthroscopy for the treatment of femoral acetabular impingement (FAI).
METHODS:
Total of 50 patients of FAI were treated by arthroscopic hip joint surgery for from January 2020 to January 2021, and were divided into two groups according to intraoperative positioning methods. Among them, 27 cases in the positioner group were treated by hip arthroscopy assisted by grid positioner including 10 males and 17 females with a mean age of (35.91±9.92) years old. In the non-locator group, 23 cases were treated with hip arthroscopy by positioning puncture according to the operator's experience including 12 males and 11 females with a mean age of (36.01±11.03) years old. Intraoperative fluoroscopy times, puncture time, adjusted puncture times and operation time of two groups were compared. The α Angle and lateral central edge(LCE) angle of hip joint were measured and compared before and after operation. Four evaluation indexes were recorded and compared, including pain visual analogue scale(VAS), hip Harris score, non-inflammatory hip joint score (NAHS), hip joint activities of daily living (HOS-ADL).
RESULTS:
All patients were followed up for 6 to 12 months with an average of (18.69±3.72) months. The α angle and LCE angle of hip joint at 1 month after operation were decreased in both groups(P<0.05), but there was no significant difference between groups(P>0.05). VAS, hip Harris score, NAHS and HOS-ADL score after operation were higher than those before operation(P<0.05), but there was no statistical significance between groups (P>0.05). Intraoperative fluoroscopy times(6.04±1.13), puncture time(13.19±3.52) min, puncture adjustment times(4.59±1.55) and operation time(48.28±3.38) min in the positioner group were less (shorter) than those of (13.43±2.56), (22.39±2.93) min, (10.43±3.33), (62.25±5.73) min in the non-positioner group(P<0.05). No postoperative complications occurred in both groups, and the pain was significantly relieved.
CONCLUSION
The application of hip arthroscopy in the treatment of femoral acetabular impingement sign can obtain good postoperative results. Compared with the traditional positioning method, the grid locator can improve the accuracy of skin positioning point, shorten the puncture time, reduce the number of fluoroscopy, and improve the efficiency of surgical puncture.
Humans
;
Male
;
Female
;
Arthroscopy/instrumentation*
;
Femoracetabular Impingement/physiopathology*
;
Adult
;
Middle Aged
;
Hip Joint/surgery*
8.Clinical features and surgical treatment strategies of hip arthroplasty for unhealed old femoral intertrochanteric fractures.
Qing XIA ; Chuan-Wen LIU ; Yu-Cheng XIA ; Hui-Yang WANG ; Jin-Quan GUO
China Journal of Orthopaedics and Traumatology 2025;38(2):188-194
OBJECTIVE:
To explore the surgical method and clinical efficacy of hip arthroplasty in the treatment of old non-union femoral intertrochanteric fractures.
METHODS:
Fifteen unoperated patients suffering from old non-union femoral intertrochanteric fractures from Feburary 2013 to Feburary 2023 were treated with hip arthroplasty including 9 males and 6 females, aged 71 to 82 years old. Eleven cases detected deep venous thrombosis(DVT), 9 cases received lower vena cava filter implantation. The operation time, intraoperative blood loss, intraoperative and postoperative blood transfusion, postoperative hemoglobin content, procedure-related complications, and the range of motion of hip flexion, abduction motion were recorded. The degree of hip pain was evaluated using a visual analogue scale(VAS). The hip Harris scores were used to evaluated the clinical efficacy.
RESULTS:
All patients were followed up for 3 to 12 months. The intraoperative blood loss was 200 to 400 ml, intraoperative blood transfusion was 0 to 400 ml, and the operation time was 40 to 90 min. All 15 patients had different degrees of anemia after surgery, the 3 days postoperative hemoglobin was 72 to 97 g·L-1, and the postoperative transfusion volume was 0 to 400 ml. All patients had no periprosthetic infection, poor incision healing, lower limb deep vein thrombosis, and cerebral infarction. One case occurred in the early postoperative period, which disappeared from 4 to 5 days after operation, and there was no further revision at the last follow-up. The VAS was 6 to 7 points before operation and 2 to 4 points at latest follow-up;the hip Harris score was 2 to 13 points before operation and 73 to 84 points at latest follow-up.
CONCLUSION
The unoperated patients of old non-union femoral intertrochanteric fractures had significant clinical and imaging characteristics. Hip arthroplasty combined with or without femoral calcar reconstruction in the treatment of old non-union femoral intertrochanteric fractures had the advantages of relatively simple manipulation, rigid fixation, relatively safe operation, and relatively exact efficacy.
Humans
;
Male
;
Female
;
Aged
;
Hip Fractures/physiopathology*
;
Aged, 80 and over
;
Arthroplasty, Replacement, Hip/methods*
9.Predictive value of combined examination of coagulation and fibrinolysis indexes for deep venous thrombosis after proximal femoral nail anti-rotation in elderly patients with femoral intertrochanteric fracture.
Hong-Feng ZHANG ; An-Ji HE ; Xi-Lin ZHAO
China Journal of Orthopaedics and Traumatology 2025;38(4):371-377
OBJECTIVE:
To investigate the prognostic significance of combined coagulation and fibrinolysis marker analysis in predicting the development of deep venous thrombosis (DVT) following proximal femoral anti-rotation intramedullary nail (PFNA) surgery in elderly patients with intertrochanteric femur fractures.
METHODS:
A retrospective analysis was conducted on the clinical data of 80 elderly patients who underwent PFNA treatment for intertrochanteric fractures between April 2019 and April 2023. There were 26 males and 54 females. The patients' ages ranged from 60 to 85 years old, with a mean age of (76.4±5.6) years old. According to the occurrence of DVT following PFNA, patients were categorized into two groups. The DVT group were 29 patients, comprising 10 males and 19 females with a mean age of (76.9 ± 6.1)years old. And the non-DVT group were 51 patients, consisting of 16 males and 35 females with a mean age of (75.3 ± 6.9 )years old. The prothrombin time (PT), activated partial thromboplastin time(APTT), thrombin time(TT), plasma fibrinogen (FIB), plasma thrombin-antithrombin complex(TAT), and D-dimer levels were compared between the two groups immediately post- PFNA surgery, as well as at 3 and 7 days postoperatively. Pearson correlation analysis was conducted to evaluate the relationship between plasma FIB, TAT, and D-dimer levels in patients who developed DVT. Multivariate logistic regression analysis was employed to assess the association between each coagulation and fibrinolysis index following PFNA surgery in elderly patients and the incidence of DVT. The area under the receiver operating characteristic (ROC) curve (AUC) was utilized to determine the predictive value of PT, APTT, TT, FIB, TAT, and D-dimer for postoperative DVT occurrence.
RESULTS:
There were no statistically significant differences in PT, APTT, and TT between the two groups immediately post-surgery, at 3 days, and at 7 days (P>0.05). At immediately, 3 days and 7 days postoperatively in DVT group, FIB were (4.68±1.77), (6.73±2.02), (8.81±2.86) g·L-1, TAT were (10.64±2.30), (12.88±3.45), (14.96±4.87) μg·L-1 respectively. D-dimer were (635.00±100.88), (720.02±168.09), (810.47±170.19) μg· L-1, respectively.In the DVT group FIB were (3.46±0.47), (3.55±0.52), (3.67±0.48) g·L-1, TAT were (8.58±3.37), (8.69±3.48), (8.80±3.50) g·L-1, D-dimer were (588.36±96.68), (589.58±96.45), (591.11±95.50) g·L-1. The difference between the two groups was statistically significant (P<0.05). Pearson correlation analysis revealed significant positive correlations between FIB and D-dimer(r=0.428, 0.523, P<0.05), FIB and TAT(r=0.517, 0.411, P<0.05), as well as TAT and D-dimer(r=0.602, 0.596, P<0.05). Multivariate Logistic regression analysis revealed that FIB OR=3.252, 95% CI(0.640, 3.975), P<0.01, TAT OR=1.461, 95% CI(1.059, 2.011), P<0.05, and D-dimer OR=3.830, 95%CI (2.032 to 7.213), P<0.01 were significantly associated with the development of DVT following PFNA surgery. The combined detection of PT, APTT, TT, FIB, TAT, and D-dimer demonstrates significantly greater predictive value for the occurrence of DVT following PFNA surgery compared to individual index detection (P<0.01).
CONCLUSION
The combined detection of PT, APTT, TT, FIB, TAT and D-D has a high predictive value for DVT in elderly patients with femoral intertrochanteric fracture after PFNA, which is of vital importance in the early diagnosis of DVT and early prevention of pulmonary embolism and other serious complications.
Humans
;
Male
;
Female
;
Venous Thrombosis/diagnosis*
;
Aged, 80 and over
;
Aged
;
Fibrinolysis
;
Retrospective Studies
;
Blood Coagulation
;
Hip Fractures/blood*
;
Fracture Fixation, Intramedullary/adverse effects*
;
Middle Aged
;
Postoperative Complications/blood*
;
Bone Nails/adverse effects*
10.Comparative study on lengthened proximal femoral nail antirotation and InterTan in the treatment of subtrochanteric femur fractures in the elderly.
Zhen-Shan WANG ; Ming-Cong DING ; Jin JIANG ; Jing-Sheng LIU ; Tong-Qun YANG
China Journal of Orthopaedics and Traumatology 2025;38(7):662-667
OBJECTIVE:
To investigate the clinical efficacy of lengthened proximal femoral nail antirotation (PFNA) and InterTan in the treatment of subtrochanteric femur fractures in the elderly.
METHODS:
A retrospective analysis was performed on the data of 65 elderly patients diagnosed with subtrochanteric femoral fractures who met the inclusion criteria between October 2016 and January 2022. The enrolled patients were categorized into two groups according to the type of internal fixation used: the lengthened proximal femoral nail antirotation(PFNA) group and the InterTan group. There were 32 patients in the PFNA group, comprising 20 males and 12 females, with ages ranging from 60 to 85 years old with an average of (69.3±6.7 ) years old. Among these patients, 15 patients resulted from traffic accidents and 17 patients were caused by falls. According to the Seinsheimer classification system, there were 11 patients as type Ⅱ, 14 patients as type Ⅲ, 6 patients as type Ⅳ, and 1 patient as type Ⅴ. The InterTan group comprised 33 patients, including 20 males and 13 females, aged from 60 to 85 years old with an average of (69.8±7.8 ) years old. Of these, 15 patients resulted from traffic accidents, while 18 patients were caused by falls. According to the Seinsheimer classification system, 10 patients as type Ⅱ, 15 patients as type Ⅲ, 7 patients as type Ⅳ, and 1 patient as type Ⅴ. The intraoperative blood loss, operative duration, and fracture healing time were recorded and compared between two groups. The quality of fracture reduction was assessed using Chang's criteria. Additionally, the Harris hip score was utilized to evaluate hip function in both groups at 3 months postoperatively and at the final follow-up.
RESULTS:
All patients were followed up for a period ranging from 10 to 20 months with an average of (14.6±4.5) months. No statistically significant differences were observed between two groups in terms of operation time, intraoperative blood loss, quality of fracture reduction, or reduction methods (P>0.05). Three months after the surgery, the Harris hip score in the InterTan group was 80.0(78.0, 83.5) points, which was significantly higher than that in the PFNA group, which recorded a score of 77.5(75.0, 81.8) points. This difference was statistically significant (P<0.05). At the final follow-up, the Harris hip score in the InterTan group was 80.0(76.5, 87.0), while that in the PFNA group was 78.0(74.3, 82.8). No statistically significant difference was observed between two groups (P>0.05).
CONCLUSION
The use of lengthened PFNA and InterTan in the treatment of elderly subtrochanteric femur fractures can both achieve good treatment results, with the advantages of simple operation, firm fixation, and low failure rate of internal fixation. The lengthened InterTan can achieve better hip function than PFNA.
Humans
;
Male
;
Female
;
Aged
;
Aged, 80 and over
;
Bone Nails
;
Retrospective Studies
;
Hip Fractures/surgery*
;
Middle Aged
;
Fracture Fixation, Intramedullary/instrumentation*
;
Fracture Fixation, Internal/methods*
;
Femoral Fractures/surgery*

Result Analysis
Print
Save
E-mail