1.Comparison of the effects of acupuncture with Neiguan(PC6)-to-Waiguan(TE5) and esmolol on hemodynamics during anesthesia induction and postoperative nausea and vomiting.
Jiping XU ; Jiafu JI ; Lan ZHAO ; Yuanyuan ZHAO ; Fan SU
Chinese Acupuncture & Moxibustion 2025;45(9):1265-1270
OBJECTIVE:
To compare the clinical efficacy of acupuncture with Neiguan (PC6)-to-Waiguan (TE5) and esmolol on hemodynamics during anesthesia induction and postoperative nausea and vomiting.
METHODS:
A total of 100 patients undergoing elective laparoscopic hernia repair or gynecological surgery under general anesthesia were randomly divided into an acupuncture group (50 cases, 3 cases were eliminated) and an esmolol group (50 cases, 2 cases were eliminated). In the acupuncture group, before anesthesia induction, patients were applied to acupuncture with Neiguan (PC6)-to-Waiguan (TE5), and the needles were retained for 15 min on the right side and 30 min on the left side. Patients in the esmolol group were intravenously injected with 20 mg esmolol hydrochloride injection 5 min before anesthesia induction. The systolic blood pressure (SBP) and heart rate (HR) of the two groups were recorded at 5 min after entering the operating room (T0), before anesthesia induction (T1), after anesthesia induction (T2), before tracheal intubation (T3) and 1 min after tracheal intubation (T4). The visual analogue scale (VAS) scores of pain and the incidence of nausea and vomiting in the two groups were observed at the time of entering postanesthesia care unit (PACU) (T5), leaving PACU (T6), 6 h after operation (T7) and 24 h after operation (T8). The dosage of anesthesia-related drugs in the two groups was counted.
RESULTS:
The SBP and HR of the two groups at T2, T3 and T4 were lower than those at T1 (P<0.05). SBP and HR at T3 in the acupuncture group were higher than those in the esmolol group (P<0.05). Compared with the esmolol group, in the acupuncture group, the VAS scores of pain at T6 and T7 were decreased (P<0.05), the incidence of nausea and vomiting at T7 and T8 and the nausea and vomiting visual analogue scale (NVAS) scores were decreased (P<0.05). Compared with the esmolol group, the dosage of propofol in the acupuncture group was decreased (P<0.05).
CONCLUSION
Acupuncture with Neiguan (PC6)-to-Waiguan (TE5) can relieve hemodynamic fluctuations during anesthesia induction, reduce postoperative pain and nausea and vomiting, and reduce the dosage of propofol. The curative effect is better than that of esmolol.
Humans
;
Female
;
Adult
;
Middle Aged
;
Acupuncture Points
;
Male
;
Hemodynamics
;
Propanolamines/administration & dosage*
;
Postoperative Nausea and Vomiting/drug therapy*
;
Young Adult
;
Heart Rate
;
Aged
;
Blood Pressure
;
Acupuncture Therapy
2.Effects of resistance combined with aerobic chrono-exercise on common carotid artery elasticity and hemodynamics in young men.
Miao-Xin JIAO ; Bing-Yi SHEN ; Hai-Bin LIU ; Li-Hong CHEN ; Guang-Rui YANG
Acta Physiologica Sinica 2025;77(4):741-751
The purpose of the present study was to investigate the effects of resistance combined with aerobic chrono-exercise on the common carotid artery elasticity and hemodynamics. 24 healthy young men (21.96±0.43 years old) underwent a single acute resistance combined with aerobic exercise intervention at eight time periods (6, 8, 10, 12, 14, 16, 18, and 20 o'clock). The axial flow velocity and diameter waveforms of the common carotid artery were measured, and the hemodynamics were calculated using the classical hemodynamic theory before exercise, immediately after exercise, 10 min and 20 min after exercise. The results showed that during exercise recovery, systolic and mean pressures decreased more markedly after exercise at 8 o'clock (P < 0.05); At 20 min post-exercise, arterial stiffness index and pressure-strain elastic modulus after exercise at 6 o'clock were reduced compared with the resting state, but were significantly elevated after exercise at 20 o'clock (P < 0.05). Immediately after exercise, the pressure rise was higher after exercise at 6 o'clock and the mean wall shear stress was higher after exercise at 20 o'clock (P < 0.05). These results suggest that resistance combined with aerobic chrono-exercise produces different effects on common carotid artery hemodynamics in young men. A single acute session of resistance combined with aerobic exercise at 8 o'clock is more effective in lowering blood pressure. Exercise at 6 o'clock is beneficial to improve arterial elasticity but is not recommended for young male individuals with cardiovascular disease risks because of the excessive increase in blood pressure immediately after exercise. Exercise at 20 o'clock is more effective in improving wall shear stress but is accompanied by elevated arterial stiffness indices and pressure-strain elastic modulus. These results provide a scientific basis for healthy young men in choosing the time of exercise by exploring the common carotid artery elasticity and hemodynamic-related indices.
Humans
;
Male
;
Young Adult
;
Exercise/physiology*
;
Carotid Artery, Common/physiology*
;
Hemodynamics/physiology*
;
Vascular Stiffness/physiology*
;
Elasticity
;
Resistance Training
;
Adult
4.Research progress on the early warning of heart failure based on remote dynamic monitoring technology.
Ying SHI ; Mengwei LI ; Lixuan LI ; Wei YAN ; Desen CAO ; Zhengbo ZHANG ; Muyang YAN
Journal of Biomedical Engineering 2025;42(4):857-862
Heart failure (HF) is the end-stage of all cardiac diseases, characterized by high prevalence, high mortality, and heavy social and economic burden. Early warning of HF exacerbation is of great value for outpatient management and reducing readmission rates. Currently, remote dynamic monitoring technology, which captures changes in hemodynamic and physiological parameters of HF patients, has become the primary method for early warning and is a hot research topic in clinical studies. This paper systematically reviews the progress in this field, which was categorized into invasive monitoring based on implanted devices, non-invasive monitoring based on wearable devices, and other monitoring technologies based on audio and video. Invasive monitoring primarily involves direct hemodynamic parameters such as left atrial pressure and pulmonary artery pressure, while non-invasive monitoring covers parameters such as thoracic impedance, electrocardiogram, respiration, and activity levels. These parameters exhibit characteristic changes in the early stages of HF exacerbation. Given the clinical heterogeneity of HF patients, multi-source information fusion analysis can significantly improve the prediction accuracy of early warning models. The results of this study suggest that, compared with invasive monitoring, non-invasive monitoring technology, with its advantages of good patient compliance, ease of operation, and cost-effectiveness, combined with AI-driven multimodal data analysis methods, shows significant clinical application potential in establishing an outpatient management system for HF.
Humans
;
Heart Failure/physiopathology*
;
Monitoring, Physiologic/methods*
;
Wearable Electronic Devices
;
Remote Sensing Technology
;
Early Diagnosis
;
Electrocardiography
;
Hemodynamics
5.Effect of lower limb amputation on hemodynamic environment of the left coronary artery: a numerical study.
Tianxiang TAI ; Wentao JIANG ; Zhongyou LI ; Junjie DIAO ; Xiao LI
Journal of Biomedical Engineering 2025;42(5):954-963
It has been found that the incidence of cardiovascular disease in patients with lower limb amputation is significantly higher than that in normal people, and the risk of developing coronary atherosclerosis is much higher than that in other high-risk groups. Numerous studies have confirmed that high systolic and diastolic blood pressures are potential risk factors for coronary artery disease, and it has been demonstrated that the ascending aortic pressure during diastole increases after amputation. However, the relationship between lower limb amputation and coronary atherosclerosis has not been fully explained from the perspective of hemodynamic environment. Therefore, in this study, a centralized parameter model of the human cardiovascular system and a three-dimensional model of the left coronary artery were established to investigate the effect of amputation on the hemodynamic environment of the coronary artery. The results showed that the abnormal hemodynamic environment induced by amputation, characterized by factors such as increased diastolic pressure in the ascending aorta, led to a significant expansion of the low wall shear stress (WSS) region on the outer lateral aspect of the left coronary artery bifurcation during diastole. The maximum observed increase in the area of low WSS reached up to 50.5%. This abnormal hemodynamic environment elevates the risk of plaque formation in the left coronary artery. Moreover, the more severe the lower limb atrophy, the greater the risk of coronary atherosclerosis in amputees. This study preliminarily reveals the effect of lower limb amputation on the hemodynamic environment of the left coronary artery.
Humans
;
Hemodynamics/physiology*
;
Amputation, Surgical/adverse effects*
;
Coronary Vessels/physiology*
;
Coronary Artery Disease/etiology*
;
Lower Extremity/surgery*
;
Models, Cardiovascular
;
Blood Pressure
6.Predictive factors for hemodynamically significant patent ductus arteriosus in preterm infants and the construction of a nomogram prediction model.
Jun MU ; Shu-Shu LI ; Ai-Ling SU ; Shu-Ping HAN ; Jin-Gai ZHU
Chinese Journal of Contemporary Pediatrics 2025;27(3):279-285
OBJECTIVES:
To explore the predictive factors for hemodynamically significant patent ductus arteriosus (hsPDA) in preterm infants and to construct a nomogram prediction model for hsPDA occurrence in this population.
METHODS:
A retrospective analysis was conducted on the clinical data of preterm infants with gestational age <32 weeks diagnosed with patent ductus arteriosus (PDA) who were delivered at Nanjing Women and Children's Healthcare Hospital from January 2020 to December 2022. The subjects were divided into an hsPDA group (52 cases) and a non-hsPDA group (176 cases) based on the presence of hsPDA. Univariate analysis and multivariate logistic regression analysis were performed to screen predictive variables regarding the general information of the infants at birth, maternal pregnancy and delivery conditions, and relevant indicators during hospitalization. A nomogram prediction model for hsPDA occurrence was constructed using R software in preterm infants. Internal validation was performed using the Bootstrap method. Finally, the predictive model was evaluated for calibration, discrimination ability, and clinical utility.
RESULTS:
Multivariate regression analysis showed that the ratio of the left atrium to aorta diameter (LA/AO), mode of delivery (vaginal), and duration of mechanical ventilation were independent predictive factors for hsPDA in preterm infants (P<0.05). Based on the results of univariate analysis and multivariate logistic regression analysis, variables used to construct the nomogram prediction model for hsPDA risk included: LA/AO ratio, mode of delivery (vaginal), duration of mechanical ventilation, 5-minute Apgar score, and the presence of neonatal respiratory distress syndrome requiring surfactant therapy. The area under the receiver operating characteristic curve for this model was 0.876 (95%CI: 0.824-0.927), and the calibrated curve was close to the ideal reference line, indicating good calibration. The Hosmer-Lemeshow test demonstrated that the model fit well, and the clinical decision curve was above the extreme curves.
CONCLUSIONS
The nomogram prediction model, constructed using five variables (LA/AO ratio, vaginal delivery, duration of mechanical ventilation, 5-minute Apgar score, and the presence of neonatal respiratory distress syndrome requiring surfactant therapy), has reference significance for predicting the occurrence of hsPDA in preterm infants and provides valuable guidance for the early clinical identification of hsPDA.
Humans
;
Ductus Arteriosus, Patent/etiology*
;
Nomograms
;
Female
;
Infant, Newborn
;
Infant, Premature
;
Retrospective Studies
;
Male
;
Hemodynamics
;
Logistic Models
;
Pregnancy
7.Risk factors for cardiopulmonary dysfunction after ligation of hemodynamically significant patent ductus arteriosus in preterm infants.
Chong-Chong LIU ; Yong LIU ; Yi ZHANG ; Dai-Cheng HAN ; Rui-Jing HE ; Shi-Wen XIA
Chinese Journal of Contemporary Pediatrics 2025;27(4):425-431
OBJECTIVES:
To investigate the risk factors for the occurrence of cardiopulmonary dysfunction following ligation of hemodynamically significant patent ductus arteriosus (hsPDA) in preterm infants.
METHODS:
A retrospective collection of clinical data was conducted on preterm infants with a gestational age of <34 weeks who were admitted to the Maternal and Child Health Hospital of Hubei Province, Tongji Medical College, Huazhong University of Science and Technology from January 2018 to August 2024. These infants underwent hsPDA ligation after 1-2 courses of failed ibuprofen treatment. Based on the occurrence of blood pressure changes and oxygenation or ventilation failure postoperatively, the infants were divided into a cardiopulmonary dysfunction group (19 cases) and a non-cardiopulmonary dysfunction group (40 cases). Binary logistic regression analysis was performed to explore risk factors for postoperative cardiopulmonary dysfunction.
RESULTS:
Binary logistic regression analysis indicated that a faster average weight gain rate preoperatively and low levels of free triiodothyronine (FT3) within one week before surgery were risk factors for cardiopulmonary dysfunction following hsPDA ligation (P<0.05). Receiver operating characteristic curve analysis showed that an average weight gain rate >11.45 g/(kg·d) and FT3 levels <2.785 pmol/L within one week before surgery had predictive value for postoperative cardiopulmonary dysfunction (P<0.05). The combination of these two indicators provided the highest predictive value (P<0.05), with an area under the curve of 0.825, a sensitivity of 79%, and a specificity of 75%.
CONCLUSIONS
An average weight gain rate exceeding 11.45 g/(kg·d) and FT3 levels below 2.785 pmol/L within one week before surgery are risk factors affecting cardiopulmonary function after hsPDA ligation. Preoperative assessment and intervention should be strengthened to reduce the risk of postoperative complications.
Humans
;
Ductus Arteriosus, Patent/physiopathology*
;
Risk Factors
;
Female
;
Infant, Newborn
;
Male
;
Retrospective Studies
;
Infant, Premature
;
Ligation/adverse effects*
;
Hemodynamics
;
Postoperative Complications/etiology*
;
Logistic Models
;
Lung Diseases/etiology*
8.Design and Implementation of Non-Invasive Hemodynamic Monitoring System Based on Impedance Cardiogram Method.
Fuhao KANG ; Qi YIN ; Yanan LIU ; Lin HUANG ; Yan HANG ; Jilun YE ; Xu ZHANG
Chinese Journal of Medical Instrumentation 2025;49(1):80-88
Hemodynamic monitoring can reflect cardiac function and blood perfusion and is an indispensable monitoring method in clinical practice. Invasive hemodynamic monitoring methods represented by the thermodilution method are limited in their clinical application scope because they require vascular cannulation. Non-invasive hemodynamic monitoring has attracted extensive attention from medical companies and clinicians at home and abroad in recent years due to its advantages such as safety, non-invasiveness, continuous monitoring, simple operation, and low cost. This paper designs a non-invasive hemodynamic monitoring system based on the impedance cardiography, including hardware, algorithm, software design, and performance parameter evaluation. Among them, the hardware part mainly includes a differential high-frequency constant current source stimulation circuit, impedance cardiogram signal acquisition, and ECG signal acquisition circuit. Signal processing includes wave filtering, impedance cardiogram signal calibration, and ECG signal and impedance cardiogram signal feature point recognition. According to the collected impedance cardiogram and ECG signals, hemodynamic parameters such as heart rate (HR), stroke volume (SV), cardiac output (CO), stroke index (SI), cardiac index (CI), and cardiac contractility index (ICON) are calculated based on the Nyboer thoracic cylinder model. After testing, the key technical indicators of the system hardware are better than that of the relevant medical device standards. The system was used to collect impedance cardiogram and ECG signal data from 40 volunteers. The calculated HR, SV, and CO, three important hemodynamic indicators, were compared with the ICONCore non-invasive cardiac output monitor of OSYPKA Medical in Germany. Their Pearson correlation coefficients were 0.992 ( P<0.001), 0.948 ( P<0.001), and 0.933 ( P<0.001), respectively, verifying that the designed system has high accuracy and reliability.
Cardiography, Impedance/methods*
;
Humans
;
Hemodynamic Monitoring/methods*
;
Equipment Design
;
Signal Processing, Computer-Assisted
;
Hemodynamics
;
Algorithms
;
Monitoring, Physiologic/methods*
;
Electrocardiography
9.Predictive value of ultrasound-derived quantitative indicators of umbilical cord hypercoiling and hemodynamic parameters for adverse pregnancy outcomes.
Xiaotan TAN ; Qichang ZHOU ; Hongxia YUAN ; Da HOU ; Yunfang ZHU ; Ruji YAO
Journal of Central South University(Medical Sciences) 2025;50(7):1179-1187
OBJECTIVES:
The diagnostic value of ultrasonographic quantitative indicators of umbilical cord coiling, such as the umbilical coiling index (UCI) and pitch value, in identifying hypercoiling and predicting adverse pregnancy outcomes remains controversial. This study aims to evaluate the predictive value of UCI, pitch value, and the cerebroplacental ratio in pregnancies complicated by umbilical cord hypercoiling.
METHODS:
Pregnant women with densely coiled umbilical cords identified by routine obstetric ultrasound at Changsha Maternal and Child Health Hospital between November 2022 and November 2024 were enrolled. Complete clinical data, including UCI, pitch value, and cerebroplacental ratio (CPR), were collected. Pregnancy outcome scores were calculated, and newborns were categorized into the normal outcome group (n=177) and adverse outcome group (n=85), with the latter further subdivided into mild (n=51), moderate (n=19), and severe (n=15) subgroups. Differences in baseline data, UCI, pitch value, and incidence of CRP<1 were compared between groups and among subgroups. Correlations between UCI, pitch value, and adverse pregnancy outcomes were analyzed. Receiver operating characteristic (ROC) curve were used to assess the predictive performance of UCI, pitch value, CPR<1, and their combinations.
RESULTS:
Compared with the normal outcome group, the adverse outcome group had higher age, parity, parity, incidence of CPR<1, and UCI, while gestational age at delivery and pitch values were lower (all P<0.05). The incidence of obesity, gestational diabetes mellitus, and hypertensive disorders of pregnancy did not differ significantly between the 2 groups (all P>0.05). The normal outcome group showed lower UCI and higher pitch values than all 3 adverse outcome subgroups (all P<0.05), while differences among the 3 adverse subgroups were not significant (all P>0.05). UCI was positively correlated with adverse pregnancy outcomes (rs=0.350, P<0.05), whereas pitch value was negatively correlated (rs=-0.286, P<0.05). ROC curve analysis showed that the area under the curve (AUC) values for predicting adverse outcomes were 0.837 for UCI, 0.886 for pitch value, and 0.610 for CPR<1, with sensitivities of 77.6%, 82.4%, and 27.1% and specificities of 78.5%, 83.6%, and 94.9%, respectively. The combined UCI+CPR<1 and pitch value+CPR<1 models yielded AUCs of 0.841 and 0.886, with sensitivities of 78.8% and 81.2% and specificities of 78.5% and 84.2%, respectively. No significant differences were found between the AUCs of UCI and pitch value (P>0.05), but both outperformed CPR<1 alone (both P<0.001). The combined models showed no significant improvement over UCI or pitch value alone (both P>0.05), though both were superior to CPR<1 alone (both P<0.001).
CONCLUSIONS
Most umbilical cord hypercoiling cases had favorable outcomes, with UCI, pitch value, CPR<1 and their combinations demonstrating significant predictive value for adverse pregnancy outcomes.
Humans
;
Female
;
Pregnancy
;
Pregnancy Outcome
;
Adult
;
Ultrasonography, Prenatal/methods*
;
Umbilical Cord/diagnostic imaging*
;
Hemodynamics
;
Predictive Value of Tests
;
Infant, Newborn
;
ROC Curve
10.Characteristics of changes in non-invasive hemodynamic parameters in neonates with septic shock.
Xiaoyi FANG ; Jinzhi XIE ; Airun ZHANG ; Guanming LI ; Silan YANG ; Xiaoling HUANG ; Jizhong GUO ; Niyang LIN
Chinese Critical Care Medicine 2025;37(1):29-35
OBJECTIVE:
To observe the characteristics of changes in non-invasive hemodynamic parameters in neonates with septic shock so as to provide clinical reference for diagnosis and treatment.
METHODS:
A observational study was conducted. The neonates with sepsis complicated with septic shock or not admitted to neonatal intensive care unit (NICU) of the First Affiliated Hospital of Shantou University Medical College were enrolled as the study subjects, who were divided into preterm infant (< 37 weeks) and full-term infant (≥ 37 weeks) according to the gestational age. Healthy full-term infants and hemodynamically stable preterm infants transferring to NICU after birth were enrolled as controls. Electronic cardiometry (EC) was used to measure hemodynamic parameters, including heart rate (HR), mean arterial pressure (MAP), stroke volume (SV), stroke volume index (SVI), cardiac output (CO), cardiac index (CI), systemic vascular resistance (SVR) and systemic vascular resistance index (SVRI), before treatment in the septic shock group, at the time of diagnosis of sepsis in the sepsis without shock group, and before the discharge from the obstetric department or on the day of transferring to NICU in the control group.
RESULTS:
Finally, 113 neonates with complete data and parental consent for non-invasive hemodynamic monitoring were enrolled, including 32 cases in the septic shock group, 25 cases in the sepsis without shock group and 56 cases in the control group. In the septic shock group, there were 17 cases at the compensated stage and 15 cases at the decompensated stage. There were 21 full-term infants (20 cured or improved and 1 died) and 11 premature infants (7 cured or improved and 4 died), with the mortality of 15.62% (5/32). There were 18 full-term infants and 7 premature infants in the sepsis without shock group and all cured or improved without death. The control group included 28 full-term infants and 28 premature infants transferring to NICU after birth. Non-invasive hemodynamic parameter analysis showed that SV, SVI, CO and CI of full-term infants in the septic shock group were significantly lower than those in the sepsis without shock group and control group [SV (mL): 3.52±0.99 vs. 5.79±1.32, 5.22±1.02, SVI (mL/m2): 16.80 (15.05, 19.65) vs. 27.00 (22.00, 32.00), 27.00 (23.00, 29.75), CO (L/min): 0.52±0.17 vs. 0.80±0.14, 0.72±0.12, CI (mL×s-1×m-2): 40.00 (36.67, 49.18) vs. 62.51 (56.34, 70.85), 60.01 (53.34, 69.68), all P < 0.05], while SVR and SVRI were significantly higher than those in the sepsis without shock group and control group [SVR (kPa×s×L-1): 773.46±291.96 vs. 524.17±84.76, 549.38±72.36, SVRI (kPa×s×L-1×m-2): 149.27±51.76 vs. 108.12±12.66, 107.81±11.87, all P < 0.05]. MAP, SV, SVI, CO and CI of preterm infants in the septic shock group were significantly lower than those in the control group [MAP (mmHg, 1 mmHg ≈ 0.133 kPa): 38.55±10.48 vs. 47.46±2.85, SV (mL): 2.45 (1.36, 3.58) vs. 3.96 (3.56, 4.49), SVI (mL/m2): 17.60 (14.20, 25.00) vs. 25.50 (24.00, 29.00), CO (L/min): 0.32 (0.24, 0.63) vs. 0.56 (0.49, 0.63), CI (mL×s-1×m-2): 40.01 (33.34, 53.34) vs. 61.68 (56.68, 63.35), all P < 0.05], while SVR and SVRI were similar to the control group [SVR (kPa×s×L-1): 1 082.88±689.39 vs. 656.63±118.83, SVRI (kPa×s×L-1×m-2): 126.00±61.50 vs. 102.37±11.68, both P > 0.05]. Further analysis showed that SV, SVI and CI of neonates at the compensation stage in the septic shock group were significantly lower than those in the control group [SV (mL): 3.60±1.29 vs. 4.73±1.15, SVI (mL/m2): 19.20±8.33 vs. 26.34±3.91, CI (mL×s-1×m-2): 46.51±20.34 vs. 61.01±7.67, all P < 0.05], while MAP, SVR and SVRI were significantly higher than those in the control group [MAP (mmHg): 52.06±8.61 vs. 48.54±3.21, SVR (kPa×s×L-1): 874.95±318.70 vs. 603.01±111.49, SVRI (kPa×s×L-1×m-2): 165.07±54.90 vs. 105.09±11.99, all P < 0.05]; MAP, SV, SVI, CO and CI of neonates at the decompensated stage in the septic shock group were significantly lower than those in the control group [MAP (mmHg): 35.13±6.08 vs. 48.54±3.21, SV (mL): 2.89±1.17 vs. 4.73±1.15, SVI (mL/m2): 18.50±4.99 vs. 26.34±3.91, CO (L/min): 0.41±0.19 vs. 0.65±0.15, CI (mL×s-1×m-2): 43.34±14.17 vs. 61.01±7.67, all P < 0.05], while SVR and SVRI were similar to the control group [SVR (kPa×s×L-1): 885.49±628.04 vs. 603.01±111.49, SVRI (kPa×s×L-1×m-2): 114.29±43.54 vs. 105.09±11.99, both P > 0.05].
CONCLUSIONS
Full-term infant with septic shock exhibit a low cardiac output, high vascular resistance hemodynamic pattern, while preterm infant with septic shock show low cardiac output and normal vascular resistance. At the compensated stage the hemodynamic change is low output and high resistance type, while at the decompensated stage it is low output and normal resistance type. Non-invasive hemodynamic monitoring can assist in the identification of neonatal septic shock and provide basis for clinical diagnosis and treatment.
Humans
;
Shock, Septic/physiopathology*
;
Infant, Newborn
;
Hemodynamics
;
Female
;
Male
;
Case-Control Studies
;
Infant, Premature

Result Analysis
Print
Save
E-mail