1.Subtrochanteric Fracture: Intramedullary Nailing.
Journal of the Korean Fracture Society 2009;22(2):114-122
No abstract available.
Fracture Fixation, Intramedullary
2.Extraction of Misplaced Endcap during Tibia Intramedullary Nailing by 'Fish-Hook' Technique: Technical Note.
Journal of the Korean Fracture Society 2015;28(3):194-197
Endcap placement after intramedullary nailing can be cumbersome. Misplacement of the endcap which may be difficult to extract may occur. In this report, a simple Kirschner wire device with 'fish-hook' technique may ease the procedure without further violating bony or soft tissues.
Fracture Fixation, Intramedullary*
;
Tibia*
3.Intramedullary Nailing of Proximal Tibial Fractures.
Journal of the Korean Fracture Society 2009;22(3):197-205
No abstract available.
Fracture Fixation, Intramedullary
4.Prebent Intramedullary Nailing of the Shaft Fracture of the Femur
Bong Kun KIM ; Kang Ill LEE ; Ki Young KIM
The Journal of the Korean Orthopaedic Association 1983;18(6):1122-1130
No abstract available in English.
Femur
;
Fracture Fixation, Intramedullary
5.The Clinical Experience of Flexible Intramedullary Nailing for Tibial Shaft Fractures
Chang Uk CHOI ; Soo Kyoon RAH ; Wan Surk CHOI ; Moo Sool KIM
The Journal of the Korean Orthopaedic Association 1984;19(1):165-174
No abstract available in English.
Fracture Fixation, Intramedullary
6.The Huckstep Intramedullary Nailing for Femoral Shaft Fractures
Soo Kil KIM ; Jong Yoon OH ; Keung Bae LEE
The Journal of the Korean Orthopaedic Association 1985;20(4):659-665
No abstract available in English.
Fracture Fixation, Intramedullary
7.A clinical comparison between plate fixation and closed intramedullary nailing in the treatment of femoral shaft fractures.
Byung Yeon HWANG ; Gang Wook LEE ; Seung Hwan LEE
The Journal of the Korean Orthopaedic Association 1992;27(5):1319-1327
No abstract available.
Fracture Fixation, Intramedullary*
8.Flexible intramedullary nailing in the treatment of tibial shaft fractures.
Seung Rim PARK ; Myung Ho KIM ; Hyoung Soo KIM ; Kyoung Ho MOON ; Young Deog KIM
The Journal of the Korean Orthopaedic Association 1992;27(5):1337-1345
No abstract available.
Fracture Fixation, Intramedullary*
9.The Distraction Effect of the Fracture Site on Insertion of the Distal Screw in Interlocking Intramedullary Nailing.
Yung Khee CHUNG ; Sung Il SHIN ; Kye Won KIM
The Journal of the Korean Orthopaedic Association 1998;33(5):1452-1459
To study the development of distraction at the fracture site according to inaccurate insertion of the distal screw in treatment of femoral shaft fracture with interlocking intramedullary nail, we prepared 24 femoral bone model, fixed them with interlocking intramedullary nails after artificially making transverse fracture or spiral fracture at mid 1/3 of femoral shaft and distal 1/3 of femoral shaft. The cephalocaudal insertion angles of the distal screws ranged from 5.2 to 45.4. As the insertion angles increased, the distances between the fractured sites ranged from 0.1 to 8.2mm. Distractions splited more than 5mm were seen in the average insertion angle of 34.3+/-9.4 (28.2 -45.4 ). When the insertion was made few millimeter proximal from the center of the distal screw hole, which was parallel to the transverse section of the femur model, fracture distraction ranged from minimum 1.8mm to maximum 5.0mm. In conclusion, the cephalocaudal insertion angle or location of the distal screw can be reason for the distraction between the fractured sites in internal fixation with intramedullary nail in long bone like femur. To prevent the distraction of fractured site, it is important to make the insertion of the distal screw parallel to the transverse section of the femur and to insert into the center of the screw hole.
Femur
;
Fracture Fixation, Intramedullary*
10.Treatment of tibial shaft fractures using unreamed intramedullary nailing.
Pjil Hyun CHUNG ; Moon Jib YOO ; Suk KANG ; Eung Nam CHA ; Yong Min KIM ; Jong Won KIM ; Hyung Ho OH
The Journal of the Korean Orthopaedic Association 1993;28(5):1725-1735
No abstract available.
Fracture Fixation, Intramedullary*