1.Comparative study of orthopaedic robot-assisted minimally invasive surgery and open surgery for limb osteoid osteoma.
Junwei FENG ; Weimin LIANG ; Yue WANG ; Zhi TANG ; MuFuSha A ; Baoxiu XU ; Niezhenghao HE ; Peng HAO
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):40-45
OBJECTIVE:
To compare the accuracy and effectiveness of orthopaedic robot-assisted minimally invasive surgery versus open surgery for limb osteoid osteoma.
METHODS:
A clinical data of 36 patients with limb osteoid osteomas admitted between June 2016 and June 2023 was retrospectively analyzed. Among them, 16 patients underwent orthopaedic robot-assisted minimally invasive surgery (robot-assisted surgery group), and 20 patients underwent tumor resection after lotcated by C-arm X-ray fluoroscopy (open surgery group). There was no significant difference between the two groups in the gender, age, lesion site, tumor nidus diameter, and preoperative pain visual analogue scale (VAS) scores ( P>0.05). The operation time, lesion resection time, intraoperative blood loss, intraoperative fluoroscopy frequency, lesion resection accuracy, and postoperative analgesic use frequency were recorded and compared between the two groups. The VAS scores for pain severity were compared preoperatively and at 3 days and 3 months postoperatively.
RESULTS:
Compared with the open surgery group, the robot-assisted surgery group had a longer operation time, less intraoperative blood loss, less fluoroscopy frequency, less postoperative analgesic use frequency, and higher lesion resection accuracy ( P<0.05). There was no significant difference in lesion resection time ( P>0.05). All patients were followed up after surgery, with a follow-up period of 3-24 months (median, 12 months) in the two groups. No postoperative complication such as wound infection or fracture occurred in either group during follow-up. No tumor recurrence was observed during follow-up. The VAS scores significantly improved in both groups at 3 days and 3 months after surgery when compared with preoperative value ( P<0.05). The VAS score at 3 days after surgery was significantly lower in robot-assisted surgery group than that in open surgery group ( P<0.05). However, there was no significant difference in VAS scores at 3 months between the two groups ( P>0.05).
CONCLUSION
Compared with open surgery, robot-assisted resection of limb osteoid osteomas has longer operation time, but the accuracy of lesion resection improve, intraoperative blood loss reduce, and early postoperative pain is lighter. It has the advantages of precision and minimally invasive surgery.
Humans
;
Robotics
;
Osteoma, Osteoid/surgery*
;
Orthopedics
;
Blood Loss, Surgical
;
Retrospective Studies
;
Neoplasm Recurrence, Local
;
Minimally Invasive Surgical Procedures
;
Bone Neoplasms/surgery*
;
Analgesics
;
Treatment Outcome
2.Development of a flexible embedded neurostimulator for animal robots.
Zhenling SU ; Dongyun WANG ; Xiaomin QI ; Chenguang YANG ; Yexin ZHANG ; Kaige LIU ; Yue QIN ; Xinyu LIU
Journal of Biomedical Engineering 2023;40(2):327-334
The neural stimulator is a core component of animal robots. While the control effect of animal robots is influenced by various factors, the performance of the neural stimulator plays a decisive role in regulating animal robots. In order to optimize animal robots, embedded neural stimulators had been developed using flexible printed circuit board technology. This innovation not only enabled the stimulator to generate parameter-adjustable biphasic current pulses through control signals, but also optimized its carrying mode, material, and size, overcoming the disadvantages of traditional backpack or head-inserted stimulators, which have poor concealment and are prone to infection. Static, in vitro, and in vivo performance tests of the stimulator demonstrated that it not only had precise pulse waveform output capability, but also was lightweight and small in size. It had excellent in vivo performance in both laboratory and outdoor environments. Our study has high practical significance for the application of animal robots.
Animals
;
Robotics
3.Bionic optic nerve based on perovskite (CsPbBr 3) quantum-dots.
Pingjun ZENG ; Xudong JIN ; Yubo PENG ; Min ZHAO ; Zhipeng GAO ; Xiaona LI ; Jianlong JI ; Weiyi CHEN
Journal of Biomedical Engineering 2023;40(3):522-528
The bionic optic nerve can mimic human visual physiology and is a future treatment for visual disorders. Photosynaptic devices could respond to light stimuli and mimic normal optic nerve function. By modifying (Poly(3,4-ethylenedioxythio-phene):poly (styrenesulfonate)) active layers with all-inorganic perovskite quantum dots, with an aqueous solution as the dielectric layer in this paper, we developed a photosynaptic device based on an organic electrochemical transistor (OECT). The optical switching response time of OECT was 3.7 s. To improve the optical response of the device, a 365 nm, 300 mW·cm -2 UV light source was used. Basic synaptic behaviors such as postsynaptic currents (0.225 mA) at a light pulse duration of 4 s and double pulse facilitation at a light pulse duration of 1 s and pulse interval of 1 s were simulated. By changing the way light stimulates, for example, by adjusting the intensity of the light pulses from 180 to 540 mW·cm -2, the duration from 1 to 20 s, and the number of light pulses from 1 to 20, the postsynaptic currents were increased by 0.350 mA, 0.420 mA, and 0.466 mA, respectively. As such, we realized the effective shift from short-term synaptic plasticity (100 s recovery of initial value) to long-term synaptic plasticity (84.3% of 250 s decay maximum). This optical synapse has a high potential for simulating the human optic nerve.
Humans
;
Quantum Dots
;
Bionics
;
Oxides
;
Optic Nerve
4.A comparative study of short-term effectiveness of "SkyWalker" robot-assisted versus traditional total knee arthroplasty.
Haoming AN ; Hangyu PING ; Haifeng LI ; Wei CHAI
Chinese Journal of Reparative and Reconstructive Surgery 2023;37(4):404-409
OBJECTIVE:
To compare the short-term effectiveness of "SkyWalker" robot-assisted total knee arthroplasty (TKA) and traditional TKA.
METHODS:
A clinical data of 54 patients (54 knees) with TKA who met the selection criteria between January 2022 and March 2022 was retrospectively analyzed. Among them, 27 cases underwent traditional TKA (traditional operation group) and 27 cases underwent "SkyWalker" robot-assisted TKA (robot-assisted operation group). There was no significant difference between the two groups ( P>0.05) in terms of gender, age, body mass index, osteoarthritis side, disease duration, and preoperative Knee Society Score (KSS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC), visual analogue scale (VAS) score, hip-knee-ankle angle (HKA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), and posterior proximal tibial angle (PPTA). The operative time, intraoperative bleeding volume, surgery-related complications, the KSS, WOMAC, and VAS scores before operation and at 6 months after operation, and Forgotten Joint Score (FJS) at 6 months after operation were recorded. X-ray films were taken to review the prosthesis position and measure HKA, LDFA, MPTA, and PPTA. The differences of the clinical and imaging indicators between before and after operation were calculated and statistically analyzed.
RESULTS:
The operations were completed successfully in both groups. There was no significant difference in the operative time and intraoperative bleeding volume between the two groups ( P>0.05). After operation, 1 case of incision nonunion and 1 case of heart failure occurred in the traditional operation group, while no surgery-related complications occurred in the robotic-assisted operation group. The incidences of surgical complications were 7.4% (2/27) in the traditional operation group and 0 (0/27) in the robotic-assisted operation group, with no significant difference ( P=0.491). Patients in both groups were followed up 6 months. KSS score, WOMAC score, VAS score, and ROM significantly improved in both groups at 6 months after operation when compared with preoperative ones ( P<0.05). There was no significant difference between the two groups ( P>0.05) in the differences between the pre- and post-operative values of the clinical indicators and FJS scores at 6 months after operation. X-ray films showed that the lower extremity force lines of the patients improved and the knee prostheses were in good position. Except for LDFA in the robot-assisted operation group, HKA, LDFA, MPTA, and PPTA significantly improved in both groups at 6 months after operation when compared with the preoperative ones ( P<0.05). There was no significant difference between the two groups in the differences between the pre- and post-operative values of the radiological indicators ( P>0.05).
CONCLUSION
The "SkyWalker" robot-assisted TKA is one of the effective methods for the treatment of knee osteoarthritis and had good short-term effectiveness. But the long-term effectiveness needs to be further studied.
Humans
;
Arthroplasty, Replacement, Knee/methods*
;
Knee Joint/surgery*
;
Knee Prosthesis
;
Osteoarthritis, Knee/surgery*
;
Retrospective Studies
;
Robotics
;
Treatment Outcome
5.Robot-assisted single lung transplantation.
Wenjie JIAO ; Ronghua YANG ; Yandong ZHAO ; Nan GE ; Tong QIU ; Xiao SUN ; Yingzhi LIU ; Kun LI ; Zhiqiang LI ; Wencheng YU ; Yi QIN ; Ao LIU
Chinese Medical Journal 2023;136(3):362-364
6.Clinical study on application of 3D Slicer software assisted domestic frameless stereotactic robot in biopsy of intracranial lesions.
Hui CHEN ; Xin YAN ; Feng HE ; Sheng Chao DING ; Jin Fu DIAO ; Hui GUO ; Shou Ming CAO ; Chun Juan YANG ; Feng YIN
Chinese Journal of Surgery 2023;61(1):61-65
Objective: To examine the application value of 3D Slicer software assisted domestic frameless stereotactic robot in biopsy of intracranial lesions. Methods: A retrospective analysis was performed on 80 patients who admitted consecutively and underwent intracerebral lesions biopsy with the domestic frameless stereotactic robot at Department of Neurosurgery, Aerospace Central Hospital from January 2019 to December 2021. There were 36 males and 44 females, with a mean age of (38.5±18.0) years (range: 6 to 71 years). Before surgery only enhanced T1-weighted three-dimensional magnetization prepared gradient echo sequences and diffusion tensor imaging scans were performed. Self-reconstruction of intracranial lesions, cerebral cortex and blood vessels was carried out using 3D Slicer software system after the DICOM format imaging data of 80 patients were collected. These imaging data were merged to the workstation of the domestic frameless stereotactic robot for preoperative surgical planning and the surgical puncture path was designed to avoid blood vessels in the brain functional area, cerebral cortex and sulcus. Results: All frameless stereotactic biopsy were successfully performed. Postoperative pathological diagnosis included 50 cases of diffuse astrocytic and oligodendroglioma, 15 cases of lymphoma, 5 cases of metastatic tumors, 5 cases of inflammatory demyelinating disease, 2 cases of inflammatory granuloma, 1 case of hemangioma, 1 case of acute lymphoblastic leukemia intracranial invasion and 1 case of seminoma. The positive diagnosis rate was 100% (80/80). Postoperative imaging confirmed that the puncture path and target were accurately implemented according to the preoperative planning, and the target error was (1.32±0.44) mm (range: 0.55 to 1.99 mm). One case of puncture-related bleeding occurred at the target after surgery and improved after treatment. Conclusion: The three-dimensional multimodal images reconstructed by the 3D Slicer software before operation could help the surgeons make the preoperative planning and reduce the risk of stereotactic brain biopsy.
Male
;
Female
;
Humans
;
Child
;
Adolescent
;
Young Adult
;
Adult
;
Middle Aged
;
Aged
;
Brain Neoplasms/pathology*
;
Diffusion Tensor Imaging
;
Retrospective Studies
;
Robotics
;
Biopsy
;
Software
;
Stereotaxic Techniques
7.Simulation design and experimental study of magnetic stimulation coil for robot pigeon.
Menghua XU ; Xin PU ; Ming CHANG ; Yang SONG ; Fuzhe MA ; Ruituo HUAI ; Junqing YANG ; Hui CHANG ; Feng SHAO ; Hui WANG
Journal of Biomedical Engineering 2023;40(1):141-148
To explore the feasibility of applying magnetic stimulation technology to the movement control of animal robots, the influence of coil radius, number of turns and other factors on the intensity, depth and focus of magnetic stimulation was simulated and analyzed for robot pigeons. The coil design scheme was proposed. The coil was placed on the head and one of the legs of the pigeon, and the leg electromyography (EMG) was recorded when magnetic stimulation was performed. Results showed that the EMG was significantly strengthened during magnetic stimulation. With the reduction of the output frequency of the magnetic stimulation system, the output current was increased and the EMG was enhanced accordingly. Compared with the brain magnetic stimulation, sciatic nerve stimulation produced a more significant EMG enhancement response. This indicated that the magnetic stimulation system could effectively modulate the functions of brain and peripheral nerves by driving the coil. This study provides theoretical and experimental guidance for the subsequent optimization and improvement of practical coils, and lays a preliminary theoretical and experimental foundation for the implementation of magnetic stimulation motion control of animal robots.
Animals
;
Columbidae
;
Robotics
;
Motion
;
Brain
;
Magnetic Phenomena
8.Early clinical application of Mako robot-assisted total knee arthroplasty in knee osteoarthritis.
China Journal of Orthopaedics and Traumatology 2023;36(2):133-139
OBJECTIVE:
To investigate the early efficacy of Mako robot-assisted total knee arthroplasty (TKA) in the treatment of knee osteoarthritis (KOA) and summarize the initial application experience.
METHODS:
Retrospective analysis of 73 patients with KOA treated with Mako robot-assisted TKA from June 2021 to December 2021. There were 16 males and 57 females, aged from 54 to 81 years old with an average of (67.8±6.6) years old. The hip knee and ankle angle (HKA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), lateral femoral component angle (LFCA) and lateral tibial component angle (LTCA) were recorded and analyzed. WOMAC score and KSS were used to compare the functional recovery of patients preoperatively, 3 and 6 months postoperatively.
RESULTS:
All the 73 patients were successfully treated without serious complications such as vascular and nerve injury, and all the incisions healed well at stageⅠwithout infection. The patients were followed up from 4 to 11 months with an average of (7.0±2.7) months, and the satisfaction rate of the last follow-up was 90.41% (66/73). WOMAC scores were (23.1±5.4) at 3 months and (14.8±4.1) at 6 months postoperatively. KSS clinical scores were ( 76.1±4.0) at 3 months and (82.1±3.7) at 6 months postoperatively;KSS functional scores were (74.3±3.1) at 3 months and (78.6±2.1) at 6 months after operation. Postoperative imaging showed good position of the prosthesis, HKA angle was (178.5±2.1)°, LDFA was (91.2±1.8)°, MPTA was(89.9±1.5) °, LFCA was (7.6±3.1)°, LTCA was (88.2±1.1)°. The mechanical axis within ±3° in sixty cases(82.2%), and the mechanical axis within ±6° in all the patients.
CONCLUSION
Mako robot-assisted TKA is a safe and effective surgery in the treatment of knee osteoarthritis, which exhibited good efficacy in the correction of lower limb alignment, soft tissue balance and improvement of knee function. The long-term efficacy needs further follow-up observation.
Male
;
Female
;
Humans
;
Middle Aged
;
Aged
;
Aged, 80 and over
;
Arthroplasty, Replacement, Knee/methods*
;
Osteoarthritis, Knee/surgery*
;
Retrospective Studies
;
Robotics
;
Knee Joint/surgery*
9.Comparison of curative effect between Tianji robot assisted screw placement and traditional cannulated screw internal fixation for femoral neck fracture.
De-Xin NIE ; Wen-Gao SUN ; Xiao-Qiang WANG ; Ming-Jun WANG ; Jin-Bo SUN ; Chun CHEN
China Journal of Orthopaedics and Traumatology 2023;36(3):221-225
OBJECTIVE:
To investigate the clinical efficacy and advantages of Tianji orthopedic robot assisted cannulated screw internal fixation for femoral neck fracture.
METHODS:
The clinical data of 41 patients with femoral neck fracture who underwent internal fixation with cannulated screws from January 2019 to January 2022 were retrospectively analyzed. According to different surgical methods, they were divided into Tianji robot group and traditional cannulated screw fixation group (traditional operation group). Among them, there were 18 patients in Tianji robot group including 8 males and 10 females with age of (56.00±4.22) years old, Garden typeⅠ (4 cases), type Ⅱ (11 cases), type Ⅲ (2 cases), and type Ⅳ (1 case). There were 23 patients in the traditional operation group, including 10 males and 13 females, aged (54.87±4.81) years old;there were 5 cases of Garden typeⅠ, 14 cases of type Ⅱ, 3 cases of type Ⅲ and 1 case of type Ⅳ. The operation time, intraoperative blood loss, fluoroscopy times, guide needle placement times, operation costs and other indicators were observed and compared between two groups. Harris score was used to evaluate hip joint function 12 months after operation.
RESULTS:
The wounds of all patients healed in Grade A without complications. There were significant differences between two groups in terms of operation time, times of intraoperative fluoroscopy, times of guide needle placement, amount of intraoperative bleeding, and operation cost (P<0.05). All 41 patients were followed up for at least 12 months. The fractures of both groups were healed. There was no infection, screw loosening, fracture displacement and femoral head necrosis in Tianji robot group during follow-up;Screw loosening occurred in 2 patients in the traditional operation group during follow-up. At 12 months after operation, Harris hip joint function score of Tianji robot group was higher than that of traditional operation group in daily activity, lameness, joint activity score and total score (P<0.05).
CONCLUSION
Tianji robot assisted nail placement is a better method for the treatment of femoral neck fracture, which improves the surgical efficiency, is more accurate, has higher success rate of one-time nail placement, shorter operation time, less radiation, and has better hip joint function recovery after surgery.
Male
;
Female
;
Humans
;
Middle Aged
;
Robotics
;
Retrospective Studies
;
Femoral Neck Fractures/surgery*
;
Bone Screws
;
Fracture Fixation, Internal/methods*
;
Treatment Outcome
10.Study on the correlation between early three-dimensional gait analysis and clinical efficacy after robot-assisted total knee arthroplasty.
Rui HE ; Ran XIONG ; Mao-Lin SUN ; Jun-Jun YANG ; Hao CHEN ; Peng-Fei YANG ; Liu YANG
Chinese Journal of Traumatology 2023;26(2):83-93
PURPOSE:
Robot-assisted technology is a forefront of surgical innovation that improves the accuracy of total knee arthroplasty (TKA). But whether the accuracy of surgery can improve the clinical efficacy still needs further research. The purpose of this study is to perform three-dimensional (3D) analysis in the early postoperative period of patients who received robot-assisted total knee arthroplasty (RATKA), and to study the trend of changes in gait parameters after RATKA and the correlation with the early clinical efficacy.
METHODS:
Patients who received RATKA in the Center of Joint Surgery, the First Hospital Affiliated to Army Military Medical University from October 2020 to January 2021 were included. The imaging parameters, i.e., hip-knee-ankle angle, lateral distal femoral angle, medial proximal tibial angle, posterior condylar angle were measured 3 months post-TKA. The 3D gait analysis and clinical efficacy by Western Ontario Mac Master University Index (WOMAC) score were performed pre-TKA, 3 and 6 months post-TKA. The differences in spatiotemporal parameters of gait, kinetic parameters, and kinematic parameters of the operated limb and the contralateral limb were compared. The correlation between gait parameters and WOMAC scores was analyzed. Paired sample t-test and Wilcoxon rank-sum test were used to analyze the difference between groups, and Spearman correlation coefficient was used to analyze the correlation.
RESULTS:
There were 31 patients included in this study, and the imaging indexes showed that all of them returned to normal post-TKA. The WOMAC score at 3 months post-TKA was significantly lower than that pre-TKA, and there was no significant difference between at 3 and 6 months. The 3D gait analysis results showed that the double support time of the operated limb reduced at 3 and 6 months (all p < 0.05), the maximum extension and maximum external rotation of the knee joint increased at stance phase, and the maximum flexion angle, the range of motion and the maximum external rotation increased at swing phase. Compared with the preoperative data, there were significant improvements (all p < 0.05). Compared with the contralateral knee joint, the maximum external rotation of the knee joint at swing phase was smaller than that of the contralateral side, and the maximum flexion and extension moment was greater than that of the contralateral knee. The maximum external rotation moment of the joint was greater than that of the contralateral knee joint (p < 0.05). There was a negative correlation between the single support time pre-TKA and the WOMAC score at 3 months (p = 0.017), and the single support time at 3 months was negatively correlated with the WOMAC score at 6 months (p = 0.043). The cadence at 6 months was negatively correlated with the WOMAC score at 6 months (p = 0.031). The maximum knee extension at stance phase at 6 months was negatively correlated with the WOMAC score at 6 month (p = 0.048). The maximum external rotation at stance phase at 6 months was negatively correlated with the WOMAC score at 6 months (p = 0.024).
CONCLUSION
The 3D gait analysis of RATKA patients is more sensitive than WOMAC score in evaluating the clinical efficacy. Trend of changes in gait parameters shows that the knee joint support, flexion and extension function, range of motion, external rotation and varus deformity moment of the patient were significantly improved at 3 months after surgery, and continued to 6 months after surgery. Compared with the contralateral knee, the gait parameters of the operated limb still has significant gaps in functionality, such as the external rotation and flexion and extension. The single support time, cadence, knee extension, and knee external rotation of the operated limb have a greater correlation with the postoperative WOMAC score. Postoperative rehabilitation exercises should be emphasized, which is of great value for improving the early efficacy of RATKA.
Humans
;
Arthroplasty, Replacement, Knee
;
Gait Analysis
;
Robotics
;
Osteoarthritis, Knee/surgery*
;
Knee Joint/surgery*
;
Treatment Outcome
;
Range of Motion, Articular
;
Biomechanical Phenomena

Result Analysis
Print
Save
E-mail