1.Study on the electric field transmission characteristics of conducted-electrode tumor treating fields.
Kaida LIU ; Junxia ZHANG ; Jiaqi SHI ; Haohan FANG ; Xing LI
Journal of Biomedical Engineering 2025;42(5):964-969
Tumor treating fields (TTF) therapy is an innovative tumor treatment modality. Currently, the TTF devices predominantly employ insulated ceramic electrodes as the electric field transmission medium, resulting in low energy transfer efficiency of the electric field and poor portability of the devices. This study proposed an innovative TTF transmission mode and independently designed a conducted-electrode TTF cell culture dish utilizing inert titanium materials. The electric field conduction characteristics were verified through finite element simulations and experimental tests. Finally, based on the self-manufactured conducted-electrode TTF cell culture dish, experiments on the proliferation inhibition of U87 tumor cells by TTF were conducted. The results demonstrated that under an applied TTF voltage of 10 V and frequency of 200 kHz, the electric field intensities within the medium for conducted and insulated electrodes are approximately 2.5 V/cm and 0.7 V/cm, respectively. Compared to conventional insulated TTF systems, the conducted-electrode TTF configuration exhibited a lower electrode voltage drop and a higher electric field intensity in the culture medium, indicating superior electric field transmission efficiency. Following 36 hours of treatment with conducted-electrode TTF on U87 cells, the proliferation inhibition rate reached approximately 50%, demonstrating effective suppression of tumor cell growth. This approach presents a potential direction for optimizing TTF treatment modality and device design.
Humans
;
Electrodes
;
Neoplasms/pathology*
;
Cell Line, Tumor
;
Cell Proliferation/radiation effects*
;
Electric Stimulation Therapy/methods*
;
Electromagnetic Fields
2.Experimental study on the treatment of postmenopausal osteoporosis with low-frequency pulsed electromagnetic fields.
Zidong AN ; Liqiang WANG ; Yi WU ; Yongjie PANG ; Keming CHEN ; Yuhai GAO
Journal of Biomedical Engineering 2025;42(5):1054-1061
This study aims to investigate the therapeutic efficacy of 50 Hz-0.6 mT low-frequency pulsed electromagnetic field (PEMF) on postmenopausal osteoporosis in ovariectomized rats. Thirty 3-month-old female SD rats were selected and divided into a sham operation group (Sham), an ovariectomized model group (OVX), and a low-frequency pulsed electromagnetic field (PEMF) treatment group, with 10 rats in each group. After 8 weeks, the whole-body bone mineral density (BMD) of each group of rats was measured. The treatment group began to receive PEMF stimulation for 90 minutes daily, while the OVX group only received a simulated placement without electricity. After 6 weeks of intervention, all rats were sacrificed and tested for in vitro BMD, micro-CT, biomechanics, serum biochemical indicators, and bone tissue-related proteins. The results showed that the BMD of the OVX group was significantly lower than that of the Sham group 8 weeks after surgery, indicating successful modeling. After 6 weeks of treatment, compared with the OVX group, the PEMF group exhibited significantly increased BMD in the whole body, femur, and vertebral bodies. Micro-CT analysis results showed improved bone microstructure, significantly increased maximum load and bending strength of the femur, elevated levels of serum bone formation markers, and increased expression of osteogenic-related proteins. In conclusion, this study demonstrates that daily 90-minute exposure to 50 Hz-0.6 mT PEMF effectively enhances BMD, improves bone biomechanical properties, optimizes bone microstructure, stimulates bone formation, and inhibits bone resorption in ovariectomized rats, highlighting its therapeutic potential for postmenopausal osteoporosis.
Female
;
Animals
;
Rats, Sprague-Dawley
;
Osteoporosis, Postmenopausal/therapy*
;
Rats
;
Bone Density
;
Ovariectomy
;
Magnetic Field Therapy/methods*
;
Electromagnetic Fields
3.Torso Simulation Research on Electromagnetic Compatibility of Implantable Neurostimulator.
Qifei LI ; Weiming WANG ; Weiqiang ZHANG ; Linzhi DAI ; Jiawei LIU
Chinese Journal of Medical Instrumentation 2025;49(2):212-218
In the YY 0989.3-2023 standard, clause 27.106 specifies the protection test against electromagnetic interference, but it only briefly describes the test level for electromagnetic exposure, and does not detail the parameters of the torso. This study aims to explore the internal field distribution for different torso parameters under electromagnetic exposure, and explore the patterns of field distribution through modeling and simulation. The results indicate that the parameters of the torso significantly affect the internal field distribution. The findings of this study provide a basis and reference for the electromagnetic compatibility test for implantable neurostimulator products.
Electromagnetic Fields
;
Implantable Neurostimulators
;
Computer Simulation
4.Research on MRI Gradient Coil Magnetic Field Induced Eddy Current Method.
Xiaotao ZHANG ; Yicheng LI ; Zhanping ZHENG ; Mingke WANG ; Like FENG ; Congbo LI
Chinese Journal of Medical Instrumentation 2025;49(3):263-268
After the production of the gradient coil of the magnetic resonance imaging system, electromagnetic field testing is required to verify whether the assembly accuracy meets the electromagnetic field requirements. Since the passive magnetic field B z satisfies the Laplace ,s equation and is a harmonic function, and according to the extreme value principle of harmonic function, the maximum or minimum values of B z can only appear on the boundaries, so the observation points of the magnetic field are generally selected on the surface of the spherical imaging area. For superconducting magnets used for human body magnetic resonance imaging, a spherical area with a center diameter of 40~50 cm is generally selected as the shimming target area. Only the field value of the target area needs to be measured, and the spherical harmonic coefficients obtained after data processing are used to determine the magnetic field performance of the gradient coil. There are many testing principles and methods for electromagnetic fields, so there is no unified way and method in the field of commercial applications. This article is based on the Gauss-Legendre numerical integration, measures and analyzes the magnetic field performance of gradient coils by building a data acquisition system, and this article applies numerical analysis methods to calculate the spherical harmonic coefficients of the magnetic field using discrete test data, providing a feasible method for the production and testing of gradient coils.
Magnetic Resonance Imaging/methods*
;
Magnetic Fields
;
Electromagnetic Fields
;
Equipment Design
5.Effects of Electromagnetic Pulses on Exosomes Secretion by A549 Cells.
Qingxia HOU ; Yingmei WANG ; Meng CAO ; Jiangzheng LIU ; Deqin KONG ; Qian ZHANG ; Weihua YU ; Guangzhou AN
Chinese Journal of Lung Cancer 2024;27(12):885-893
BACKGROUND:
Numerous researches indicated that electromagnetic pulses (EMP) possessed advantages such as strong targeting, minimal side-effects and low treatment cost in tumor therapy, but its optimum parameters for treatment and the relationship between EMP and tumor-derived exosomes remains unclear. This study aims to clarify the effects of EMP with different parameters on the quantity and miRNA (microRNA) of exosomes secreted by human non-small cell lung cancer A549 cells, providing beneficial reference for the clinical application of EMP and related research.
METHODS:
A549 cells were randomly divided into control group and different EMP radiation groups with respective intensity of 400, 600 and 800 kV/m. EMP was performed with 2000 pulses once, 20 Hz of repetition frequency and 120 ns of pulse width. A549 cells were radiated once per day for continuous 3 days. After radiation, exosomes were collected and identified; cell number was measured by trypan blue staining; the concentration of exosomes was measured by nanoparticle tracking analysis (NTA); the abundance of miRNAs was determined by miRNA sequencing.
RESULTS:
Compared with control group, the morphology and cell viability of A549 cells in radiation group was not different, but the quantity of exosomes in 400 or 800 kV/m radiation group was significantly decreased (P<0.05), in contrast with obvious increase in 600 kV/m radiation group (P<0.05). The abundance of exosomal miRNAs between control group and each EMP group was obviously different (P<0.05) and target genes of differentially abundant miRNAs enriched in different pathways.
CONCLUSIONS
Under the experimental condition, the quantity and miRNA abundance of exosomes could be changed by EMP radiation, which could further influence the function of tumor-derived exosomes.
Humans
;
Exosomes/genetics*
;
A549 Cells
;
MicroRNAs/metabolism*
;
Lung Neoplasms/pathology*
;
Cell Survival/radiation effects*
;
Electromagnetic Fields
6.Exposure to Electromagnetic Fields from Mobile Phones and Fructose consumption Coalesce to Perturb Metabolic Regulators AMPK/SIRT1-UCP2/FOXO1 in Growing Rats.
Ruchi TRIPATHI ; Sanjay Kumar BANERJEE ; Jay Prakash NIRALA ; Rajani MATHUR
Biomedical and Environmental Sciences 2023;36(11):1045-1058
OBJECTIVE:
In this study, the combined effect of two stressors, namely, electromagnetic fields (EMFs) from mobile phones and fructose consumption, on hypothalamic and hepatic master metabolic regulators of the AMPK/SIRT1-UCP2/FOXO1 pathway were elucidated to delineate the underlying molecular mechanisms of insulin resistance.
METHODS:
Weaned Wistar rats (28 days old) were divided into 4 groups: Normal, Exposure Only (ExpO), Fructose Only (FruO), and Exposure and Fructose (EF). Each group was provided standard laboratory chow ad libitum for 8 weeks . Additionally, the control groups, namely, the Normal and FruO groups, had unrestricted access to drinking water and fructose solution (15%), respectively. Furthermore, the respective treatment groups, namely, the ExpO and EF groups, received EMF exposure (1,760 MHz, 2 h/day x 8 weeks). In early adulthood, mitochondrial function, insulin receptor signaling, and oxidative stress signals in hypothalamic and hepatic tissues were assessed using western blotting and biochemical analysis.
RESULT:
In the hypothalamic tissue of EF, SIRT1, FOXO 1, p-PI3K, p-AKT, Complex III, UCP2, MnSOD, and catalase expressions and OXPHOS and GSH activities were significantly decreased ( P < 0.05) compared to the Normal, ExpO, and FruO groups. In hepatic tissue of EF, the p-AMPKα, SIRT1, FOXO1, IRS1, p-PI3K, Complex I, II, III, IV, V, UCP2, and MnSOD expressions and the activity of OXPHOS, SOD, catalase, and GSH were significantly reduced compared to the Normal group ( P < 0.05).
CONCLUSION
The findings suggest that the combination of EMF exposure and fructose consumption during childhood and adolescence in Wistar rats disrupts the closely interlinked and multi-regulated crosstalk of insulin receptor signals, mitochondrial OXPHOS, and the antioxidant defense system in the hypothalamus and liver.
Humans
;
Rats
;
Animals
;
Adult
;
Rats, Wistar
;
Fructose/metabolism*
;
Catalase
;
Receptor, Insulin/metabolism*
;
AMP-Activated Protein Kinases/metabolism*
;
Electromagnetic Fields/adverse effects*
;
Sirtuin 1/metabolism*
;
Cell Phone
;
Phosphatidylinositol 3-Kinases/metabolism*
;
Forkhead Box Protein O1/metabolism*
;
Uncoupling Protein 2
7.Effects of 50 Hz electromagnetic field on rat working memory and investigation of neural mechanisms.
Longlong WANG ; Shuangyan LI ; Tianxiang LI ; Weiran ZHENG ; Yang LI ; Guizhi XU
Journal of Biomedical Engineering 2023;40(6):1135-1141
With the widespread use of electrical equipment, cognitive functions such as working memory (WM) could be severely affected when people are exposed to 50 Hz electromagnetic fields (EMF) for long term. However, the effects of EMF exposure on WM and its neural mechanism remain unclear. In the present paper, 15 rats were randomly assigned to three groups, and exposed to an EMF environment at 50 Hz and 2 mT for a different duration: 0 days (control group), 24 days (experimental group I), and 48 days (experimental group II). Then, their WM function was assessed by the T-maze task. Besides, their local field potential (LFP) in the media prefrontal cortex (mPFC) was recorded by the in vivo multichannel electrophysiological recording system to study the power spectral density (PSD) of θ and γ oscillations and the phase-amplitude coupling (PAC) intensity of θ-γ oscillations during the T-maze task. The results showed that the PSD of θ and γ oscillations decreased in experimental groups I and II, and the PAC intensity between θ and high-frequency γ (hγ) decreased significantly compared to the control group. The number of days needed to meet the task criterion was more in experimental groups I and II than that of control group. The results indicate that long-term exposure to EMF could impair WM function. The possible reason may be the impaired communication between different rhythmic oscillations caused by a decrease in θ-hγ PAC intensity. This paper demonstrates the negative effects of EMF on WM and reveals the potential neural mechanisms from the changes of PAC intensity, which provides important support for further investigation of the biological effects of EMF and its mechanisms.
Humans
;
Rats
;
Animals
;
Memory, Short-Term/physiology*
;
Electromagnetic Fields/adverse effects*
;
Prefrontal Cortex
;
Cognition
8.Analysis of Radio Frequency Identification Immunity Standard for Medical Equipment.
Chinese Journal of Medical Instrumentation 2023;47(1):106-109
Aiming at the increasing application of RFID technology in the medical environment, this study introduces the foreign requirements for RFID immunity test of medical devices, compares them with the current immunity test requirements of medical devices in China, and puts forward the necessity of establishing relevant test specifications in China.
Radio Frequency Identification Device
;
Electromagnetic Fields
;
Radio Waves
;
Equipment Safety
;
Technology
9.Effect of pulsed electromagnetic fields on mesenchymal stem cell-derived exosomes in inhibiting chondrocyte apoptosis.
Yang XU ; Qian WANG ; Xiangxiu WANG ; Xiaona XIANG ; Jialei PENG ; Jiangyin ZHANG ; Hongchen HE
Journal of Biomedical Engineering 2023;40(1):95-102
The study aims to explore the effect of mesenchymal stem cells-derived exosomes (MSCs-Exo) on staurosporine (STS)-induced chondrocyte apoptosis before and after exposure to pulsed electromagnetic field (PEMF) at different frequencies. The AMSCs were extracted from the epididymal fat of healthy rats before and after exposure to the PEMF at 1 mT amplitude and a frequency of 15, 45, and 75 Hz, respectively, in an incubator. MSCs-Exo was extracted and identified. Exosomes were labeled with DiO fluorescent dye, and then co-cultured with STS-induced chondrocytes for 24 h. Cellular uptake of MSC-Exo, apoptosis, and the protein and mRNA expression of aggrecan, caspase-3 and collagenⅡA in chondrocytes were observed. The study demonstrated that the exposure of 75 Hz PEMF was superior to 15 and 45 Hz PEMF in enhancing the effect of exosomes in alleviating chondrocyte apoptosis and promoting cell matrix synthesis. This study lays a foundation for the regulatory mechanism of PEMF stimulation on MSCs-Exo in inhibiting chondrocyte apoptosis, and opens up a new direction for the prevention and treatment of osteoarthritis.
Animals
;
Rats
;
Apoptosis
;
Chondrocytes
;
Electromagnetic Fields
;
Exosomes/physiology*
;
Mesenchymal Stem Cells/metabolism*
10.Explored the Function of Electromagnetic Compatibility (EMC) of Medical Devices from the Perspective of Test.
Zhipeng GAO ; Moda XU ; Wei ZHANG ; Yanling LIU ; Xiangjun CAO ; Haoxing HE
Chinese Journal of Medical Instrumentation 2023;47(4):442-444
OBJECTIVE:
To improve the electromagnetic compatibility (EMC) quality of medical devices, improve the efficiency of EMC testing, and promote the speed of market approval.
METHODS:
The unqualified cases of EMC test items of medical devices in recent years were statistically analyzed, and the reasons of low EMC quality of medical devices were analyzed from the perspective of test.
RESULTS:
Based on the analysis of the reasons, the suggestions were given from the perspectives of medical device manufacturers and testing organizations.
CONCLUSIONS
In order to ensure the quality of EMC of medical devices, medical device manufacturers, regulatory authorities and inspection and testing institutions should strengthen the monitoring and evaluation of medical device electromagnetic compatibility, to ensure the safety of products work together to promote the development of the medical device industry healthily and orderly.
Electromagnetic Phenomena
;
Industry
;
Electromagnetic Fields

Result Analysis
Print
Save
E-mail