1.Guidelines for computer-aided design/computer-aided manufacturing custom fiber post-and-core.
Chinese Journal of Stomatology 2025;60(1):3-7
The post-and-core is a widely accepted method to restore endodontically treated teeth with compromised tooth structure. Currently, cast metal post-and-core systems and prefabricated fiber posts combined with composite resin cores are the most frequently options in dental clinical practice, but both also come with advantages and limitations. The development of computer-aided design/computer-aided manufacturing (CAD/CAM) custom fiber post-and-core represents one of the significant trends in the advancement of dentistry. Society of Digital Dental Industry, National Association of Health Industry and Enterprise Management organized experts to formulate Guidelines for CAD/CAM custom fiber post-and-core, standardizing the clinical operation procedures of this technology, enhancing the success rate of CAD/CAM custom fiber post-and-core, and promoting its application and development.
Computer-Aided Design
;
Humans
;
Post and Core Technique
;
Composite Resins
;
Dental Prosthesis Design
2.A cross-sectional study on improving clinical efficiency through centralized digital impression.
West China Journal of Stomatology 2025;43(1):63-67
OBJECTIVES:
This study aims to explore the effect of improving clinical efficiency by replacing traditional impression workflow with centralized digital impression workflow.
METHODS:
The department of prosthodontics in Center of Stomatology, Peking University Shenzhen Hospital has improved the clinical workflow by replacing the traditional impression made by doctors using impression materials for each patient with a centralized digital impression made by one technician for all patients in the department. This cross-sectional study recorded the chairside time required for impression taking in patients undergoing single posterior zirconia full crown restoration before clinical process improvement; the time required for centralized digital impression production; the comfort level of patients; and the adjacency relationship, occlusal contact relationship, and time required for prostheses adjusting (i.e., whether centralized digital impressions would compromise the quality of pro-stheses and increase the time of prostheses adjusting).
RESULTS:
The average time to make a traditional impression was (9.98±1.41) min, and the average time required for each patient to make a centralized digital impression was (5.98±1.49) min, which was shorter than that to used make a traditional impression (P<0.05). Centralized digital impression made patients feel more comfortable compared with traditional impression (P<0.05). The adjacency relationship of restorations by centralized digital impression was more appropriate (P<0.05), and no significant difference in occlusal relationship was found (P>0.05). The time required for adjusting prostheses also had no significant differences (P>0.05).
CONCLUSIONS
Centralized digital impression can improve clinical efficiency for patients undergoing single posterior zirconia crown restoration. The time for impression taking is shorter, and patients feel more comfortable without compromising the quality of the prostheses.
Humans
;
Cross-Sectional Studies
;
Dental Impression Technique
;
Crowns
;
Zirconium
;
Workflow
;
Computer-Aided Design
;
Time Factors
;
Dental Impression Materials
3.Analysis of situations prone to insufficient spaces in tooth surface preparation with the fixed-depth groove method.
Yueqian ZHANG ; Rongrong NIE ; Xiangfeng MENG
West China Journal of Stomatology 2025;43(3):370-375
OBJECTIVES:
Digitally collect data on the preparation space of the molar occlusal surface for full crown restoration and analyze the minimum preparation spaces and areas prone to insufficient preparation.
METHODS:
A total of 846 molars (excluding third molars) designated for repair with zirconium dioxide crowns were selected. All molars were prepared by using the fixed-depth groove method under visual guidance. A digital impression was collected, and the occlusal surface of the preparation was divided into regions: mesiobuccal area, mesiolingual area, distobuccal area, distolingual area, mesial marginal ridge, and distal marginal ridge. Image measurement software (3Shape Unite) was employed to record the smallest preparation space on the molar occlusal surface, and a space of <1 mm was defined as insufficient preparation. The chi-square test was utilized for the statistical analysis of data.
RESULTS:
Significant differences were observed in the areas with the smallest preparation space on the occlusal surface of molars across different quadrants (P<0.05). Notably, the area with the smallest preparation space on the occlusal surface of the maxillary first molar was most frequently found in the mesiobuccal area, whereas the smallest preparation spaces on other molars were predominantly located in the distolingual area. The insufficient preparation of the occlusal surface occurred in 41.0% (347 cases) of teeth. The distribution of prone areas corresponded with the distribution of the smallest spatial areas.
CONCLUSIONS
Although the fixed-depth groove method is employed, the preparation space on the molar surface unavoidably remains uneven under visual guidance. The identification of the areas prone to minimum preparation spaces can serve as a valuable guide for clinicians to prevent insufficient preparation.
Humans
;
Molar/anatomy & histology*
;
Crowns
;
Zirconium
4.Resin short post retention for reattachment of a fractured crown in a young permanent tooth with complicated crown-root fracture and root fracture: a case report.
Yuanyuan WANG ; Huihui CHANG ; Birong ZHANG ; Zhiqing LIAO
West China Journal of Stomatology 2025;43(4):525-529
This report presents a case of a 9-year-old child with a complicated crown-root fracture of the maxillary central incisor, accompanied with a root fracture. The treatment strategy was minimally invasive, focusing on vital pulp preservation, root fracture recovery, and crown restoration. The fractured crown was reattached using resin short posts to enhance retention, resulting in aesthetic and functional restoration of the anterior teeth. A 2-year follow-up revealed favorable clinical and radiographic outcomes.
Humans
;
Child
;
Tooth Fractures/therapy*
;
Tooth Root/injuries*
;
Incisor/injuries*
;
Tooth Crown/injuries*
;
Post and Core Technique
;
Dental Restoration, Permanent/methods*
;
Maxilla
5.Preliminary study on the influence of the dimensional stability of 3D printed resin master model on the replication accuracy of implant replicas.
Xin LI ; Yuzong LU ; Yongtao YANG ; Aonan WEN ; Yong WANG ; Yijiao ZHAO
West China Journal of Stomatology 2025;43(5):689-695
OBJECTIVES:
This study aimed to investigate the influence of the dimensional stability of 3D printed resin master model on the replication accuracy of implant replicas.
METHODS:
Ten digital impressions of patients undergoing continuous crowns or fixed bridge restoration supported by two implants were obtained, and resin models with implant replicas were 3D printed. Scanning rods were fixed on the replicas 3, 7, and 14 days after printing. The 3D, linear, and angular deviations of the scanning rods at different times were analyzed through Geomagic Wrap 2021 software.
RESULTS:
The position of the replicas shifted mesiolingually, in the same direction as the shrinkage of the model. From day 7 onward, the 3D, distance linear, and angular deviations of the replicas (scanning rod) significantly increased compared with those on the 3rd day (P<0.05). On the 14th day, the changes were even more pronounced, with the above deviations showing statistical significance (P<0.05) compared with those for the 3-day and 7-day groups. No statistical difference in height linear deviation was observed among the groups.
CONCLUSIONS
The insufficient dimensional stability of 3D printed resin models can lead to changes in the relative position and angle of the replicas, thereby affecting the accuracy of the replicas in recreating the implant's position. Complete manufacturing of prosthesis is recommended within 7 days after the model is printed.
Printing, Three-Dimensional
;
Humans
;
Dental Implants
;
Models, Dental
;
Dental Impression Technique
;
Crowns
6.Changing scanning angles on improving finish line trueness of the full crown preparation.
Nan JIANG ; Xu Dong BAO ; Lin YUE
Chinese Journal of Stomatology 2023;58(2):158-164
Objective: To explore the effect of scanning methods on finish line trueness of the full crown preparation. Methods: The standard full crown preparation model of the right maxillary first molars was prepared by using the maxillary standard resin dentition model. The standard preparation was scanned by imetric scanner and data were used as the true value. CEREC Omnicam and 3Shape TRIOS were used to scan the standard preparation. According to the scanning methods, they were divided into parallel scanning group, occlusal wave scanning group and buccolingual wave scanning group. Each group was scanned repeatedly 6 times. The data were imported into Geomagic Studio 2013 software, and the local finish line image data of the mesial, distal, buccal and lingual regions of the full crown preparation were extracted respectively. Three-dimensional deviation analysis was performed with the reference true value, and the root- mean-square error (RMSE) was the evaluation index of scanning trueness. The statistical method was one-way ANOVA. Results: Parallel scanning group: in general, the RMSE value of complete finish lines of scanner B [(35±6) μm] was significantly lower than that of scanner A [(44±7) μm](P<0.05). After scanner A occlusal wave scanning, the RMSE values of the mesial and distal finish lines [(33±5) and (50±12) μm] were significantly lower than those of parallel scanning group (P<0.05). After buccal and lingual wave scanning, the RMSE values of local finish lines in the mesial, distal, buccal and lingual regions [(37±3), (50±6), (28±6) and (29±8) μm] were significantly lower than those in parallel scanning group [(45±9), (63±7), (38±3) and (40±3) μm] (P<0.05). No significant difference was found in the RMSE values of the mesial, distal, buccal and lingual regions of scanner B between parallel scanning group, occlusal wave scanning group and buccolingual scanning group (P>0.05). Conclusions: The scanning trueness of the full crown preparation finish line obtained by the active triangulation scanning equipment can be improved by changing the scanning method to wave scanning.
Humans
;
Imaging, Three-Dimensional
;
Dental Impression Technique
;
Computer-Aided Design
;
Dental Care
;
Crowns
7.Prediction, analysis and application of learning curve of tooth preparation for all ceramic crowns of maxillary central incisors.
Si Yu WU ; Ya Ning LI ; Xiao ZHANG ; Long Wei LV ; Yun Song LIU ; Hong Qiang YE ; Yong Sheng ZHOU
Journal of Peking University(Health Sciences) 2023;55(1):108-113
OBJECTIVE:
To predict the learning curve of tooth preparation for all ceramic crowns of maxillary central incisors on phantom head simulators for graduate students participating in standardized dental resident training based on the modified Wright learning curve model, then to analyze and applicate the learning curve.
METHODS:
Twelve graduate students participating in standardized dental resident training were selected to prepare the resin maxillary central incisors on phantom head simulators for all ceramic crowns 4 times. The results of preparation were evaluated by 3 prosthetic experts with at least 10 years' experience focusing on the reduction, contour, taper, shoulder, finish line, margin placement, adjacent tooth injury, and preparation time for tooth preparation. The learning rate of tooth preparation was calculated by scores of tooth preparation of 4 times. The learning curve of tooth preparation was predicted based on the modified Wright learning curve model. According to the criteria of standardized training skill examinations for dental residents in Beijing, 80 was taken as the qualified standard score. The minimum training times for tooth preparation to satisfy the qualified standard score (80) was calculated, to analyze the characteristics of learning curve and evaluate the effectiveness of tooth preparation.
RESULTS:
The scores of 4 tooth preparation were 64.03±7.80, 71.40±6.13, 74.33±5.96, and 75.98±4.52, respectively. The learning rate was (106±4)%, which showed the learning curve an upward trend. There were no significant differences between the qualified standard score and the predicted scores of tooth preparation from the 5th preparation to the 13th preparation (P > 0.05). The predicted score of the 14th preparation was higher than the qualified standard score (P < 0.05).
CONCLUSION
The trend of the learning curve of tooth preparation for all ceramic crowns of maxillary central incisors on phantom head simulators for graduate students participating in standardized dental resident training is upward, which predicts the minimum training times higher than the qualified standard score is 14 times.
Humans
;
Tooth Preparation, Prosthodontic/methods*
;
Incisor
;
Learning Curve
;
Crowns
;
Tooth Preparation
;
Ceramics
;
Dental Porcelain
;
Dental Prosthesis Design
8.Three-dimensional finite element analysis of cement flow in abutment margin-crown platform switching.
Meng En OU ; Yun DING ; Wei Feng TANG ; Yong Sheng ZHOU
Journal of Peking University(Health Sciences) 2023;55(3):548-552
OBJECTIVE:
To analyze the cement flow in the abutment margin-crown platform switching structure by using the three-dimensional finite element analysis, in order to prove that whether the abutment margin-crown platform switching structure can reduce the inflow depth of cement in the implantation adhesive retention.
METHODS:
By using ANSYS 19.0 software, two models were created, including the one with regular margin and crown (Model one, the traditional group), and the other one with abutment margin-crown platform switching structure (Model two, the platform switching group). Both abutments of the two models were wrapped by gingiva, and the depth of the abutment margins was 1.5 mm submucosal. Two-way fluid structure coupling calculations were produced in two models by using ANSYS 19.0 software. In the two models, the same amount of cement were put between the inner side of the crowns and the abutments. The process of cementing the crown to the abutment was simulated when the crown was 0.6 mm above the abutment. The crown was falling at a constant speed in the whole process spending 0.1 s. Then we observed the cement flow outside the crowns at the time of 0.025 s, 0.05 s, 0.075 s, 0.1 s, and measured the depth of cement over the margins at the time of 0.1 s.
RESULTS:
At the time of 0 s, 0.025 s, 0.05 s, the cements in the two models were all above the abutment margins. At the time of 0.075 s, in Model one, the gingiva was squeezed by the cement and became deformed, and then a gap was formed between the gingiva and the abutment into which the cement started to flow. In Model two, because of the narrow neck of the crown, the cement flowed out from the gingival as it was pressed by the upward counterforce from the gingival and the abutment margin. At the time of 0.1 s, in Model one, the cement continued to flow deep inside with the gravity force and pressure, and the depth of the cement over the margin was 1 mm. In Model two, the cement continued to flow out from the gingival at the time of 0.075 s, and the depth of the cement over the margin was 0 mm.
CONCLUSION
When the abutment was wrapped by the gingiva, the inflow depth of cement in the implantation adhesive retention can be reduced in the abutment margin-crown platform switching structure.
Finite Element Analysis
;
Cementation/methods*
;
Gingiva
;
Crowns
;
Dental Abutments
;
Dental Cements
;
Dental Stress Analysis
9.The infection control of post-and-core crown restoration.
Cui HUANG ; Jiakang ZHU ; Qian WANG
West China Journal of Stomatology 2023;41(3):247-253
Post-and-core crown is one of the most common forms of restoration of tooth after root canal therapy (RCT). Infection control is the core objective of RCT, which is usually well realized by endodontists. However, many prosthodontists often neglect the infection control of the tooth and the maintenance of the curative effect of RCT during the process of post-and-core crown, which may lead to the failure of the final restoration. The concept of integrated crown-root treatment advocated recently requires clinicians to consider the RCT and final restoration as a whole, rather than simply divided into two parts-endodontic treatment and restorative treatment. As the core content of integrated crown-root treatment, infection control should be taken seriously by clinicians and implemented throughout the whole treatment process, especially in the restorative treatment that is easily overlooked after RCT. Therefore, this article describes the infection control of post-and-core crown restoration, classifies the tooth requiring post-and-core crown restoration, and puts forward the measures of infection control before and during post-and-core crown restoration, in order to provide reference and guidance for clinical practice.
Humans
;
Crowns
;
Tooth Crown
;
Post and Core Technique
;
Root Canal Therapy
;
Infection Control
;
Tooth Fractures
10.Initial establishment of digital reference standardized crown models of the primary teeth.
Sha Wei FENG ; Hui GUO ; Yong WANG ; Yi Jiao ZHAO ; He LIU
Journal of Peking University(Health Sciences) 2022;54(2):327-334
OBJECTIVE:
To explore the construction process of the digital reference crown models, and to initially establish the digital reference crown models of the primary teeth to lay the foundation for the establishment of the standardized crown models and the future related applications of computer-aided design/computer-aided manufacture (CAD/CAM) technology to pediatric dentistry.
METHODS:
This study randomly selected children who were caries free, aged from 4 to 5 years in several kindergartens of Haidian District of Beijing.Plaster dental models were made for the children after taking complete impressions.The digital dental models were reconstructed by using the three-dimensional (3D) dental model scanner.And then, Geomagic Studio, a 3D reverse engineering software, was employed to extract the single dental crown data, the mesiodistal and buccolingual diameters and the height of the crowns were measured.The object was reduced or enlarged by a numerical factor, and then the size of each dental crown was standardized.A total of 3-5 points features on the crown were created, and all the objects were aligned through the functions of feature-based alignment.Finally, through average-based object creation and smoothing, the digital models of reference crowns of the primary teeth were established.
RESULTS:
A total of 40 plaster dental models from 16 boys and 26 girls were selected out for our further study.The digital dental models were reconstructed, and the mesiodistal and buccolingual diameters and the height of the crowns were measured by using reverse engineering technology.Comparing the results of using mesiodistal diameter, buccolingual diameter and height as the standards, we chose the mesiodistal diameters of crowns to do the standardization, and successfully established the digital reference models of 20 primary teeth crowns with detailed surface characteristics.
CONCLUSION
In this study, the digital reference crown models of the primary teeth were established by reverse engineering technology, providing reference value for the standardized crown models and application for clinical practice, scientific research and teaching.Furthermore, this study also contributes to the extensive application of CAD/CAM technology in pediatric dentistry and the development of CAD/CAM dental systems with independent intellectual property rights.
Child
;
Computer-Aided Design
;
Crowns
;
Dental Prosthesis Design
;
Female
;
Humans
;
Male
;
Software
;
Tooth Crown
;
Tooth, Deciduous

Result Analysis
Print
Save
E-mail