1.Surgical Reconstruction for High-Output Chylothorax Associated with Thrombo-Occlusion of Superior Vena Cava and Left Innominate vein in a Neonate.
You Jung OK ; Young Hwue KIM ; Chun Soo PARK
The Korean Journal of Thoracic and Cardiovascular Surgery 2018;51(3):202-204
We report a case of high-output chylothorax associated with thrombo-occlusion of the superior vena cava (SVC) and left innominate vein (LIV) following an arterial switch operation in a neonate. The chylothorax was resolved by 3 weeks after surgical reconstruction of the SVC and LIV using fresh autologous pericardium. We confirmed the patency of the SVC and LIV with a 1-year follow-up computed tomographic scan at our outpatient clinic.
Ambulatory Care Facilities
;
Arterial Switch Operation
;
Brachiocephalic Veins*
;
Chylothorax*
;
Follow-Up Studies
;
Humans
;
Infant, Newborn*
;
Pericardium
;
Thrombosis
;
Vena Cava, Superior*
2.Retroaortic Course and Azygous Continuation of an Aberrant Left Brachiocephalic Vein
Korean Circulation Journal 2018;48(8):763-765
No abstract available.
Brachiocephalic Veins
3.Does the direction of J-tip of the guide-wire influence the misplacement of subclavian catheterization?.
Changshin KANG ; Sunguk CHO ; Hongjoon AHN ; Jinhong MIN ; Wonjoon JEONG ; Seung RYU ; Segwang OH ; Seunghwan KIM ; Yeonho YOU ; Jungsoo PARK ; Jinwoong LEE ; Insool YOO ; Yongchul CHO
Journal of the Korean Society of Emergency Medicine 2018;29(6):636-640
OBJECTIVE: Central venous catheter (CVC) misplacement can result in incorrect readings of the central venous pressure, vascular erosion, and intravascular thrombosis. Several studies have examined the correlation between the guidewire J-tip direction and misplacement rate. This study examined whether the guidewire J-tip direction (cephalad vs. caudad) affects the misplacement rate in right subclavian venous catheterization. METHODS: This prospective randomized controlled study was conducted between February 2016 and February 2017. The subjects were divided into two groups (cephalad group vs. caudad group) and the misplacement rate was compared according to guidewire J-tip direction in each group. RESULTS: Of 100 patients, the cephalad and caudad groups contained 50 patients each. The age, sex, and operator experience were similar in the two groups. In the cephalad group, misplacement of CVC insertion into the ipsilateral internal jugular vein occurred in two cases. In the caudad group, misplacement of CVC insertion into the contralateral subclavian vein occurred in one case, with loop formation in the brachiocephalic trunk in one case. Guidewire J-tip direction showed no significant correlation with CVC misplacement. CONCLUSION: The guidewire J-tip direction does not influence the rate of misplacement.
Brachiocephalic Trunk
;
Catheterization*
;
Catheters*
;
Central Venous Catheters
;
Central Venous Pressure
;
Humans
;
Jugular Veins
;
Prospective Studies
;
Reading
;
Subclavian Vein
;
Thrombosis
4.Alternative Strategies for Central Venous Stenosis and Occlusion in Patients Requiring Haemodialysis Access.
Keith KOH ; Ye Xin KOH ; Edward Tc CHOKE ; John Cc WANG ; Ch'ng Jack KIAN
Annals of the Academy of Medicine, Singapore 2017;46(1):39-41
Angiography
;
Arteriovenous Shunt, Surgical
;
Brachiocephalic Veins
;
diagnostic imaging
;
Collateral Circulation
;
Constriction, Pathologic
;
diagnostic imaging
;
Female
;
Humans
;
Jugular Veins
;
diagnostic imaging
;
Kidney Failure, Chronic
;
therapy
;
Male
;
Middle Aged
;
Phlebography
;
Renal Dialysis
;
methods
;
Subclavian Vein
;
diagnostic imaging
;
Vascular Access Devices
5.Central venous catheter malposition due to dialysis catheter: a case report.
Parnandi Bhaskar RAO ; Neha SINGH ; Sumanth SAMSON
Korean Journal of Anesthesiology 2016;69(5):532-534
A 56-year-old man on maintenance hemodialysis was admitted to the intensive care unit with septic shock and coagulopathy. As there was a dialysis catheter in the right internal jugular vein, the left internal jugular vein was cannulated with a central venous catheter to initiate vasopressor therapy. A chest X-ray showed formation of a catheter loop inside the left brachiocephalic vein, probably due to hindrance by the dialysis catheter. This report describes the hurdles encountered, repeated cannulation attempts, and serial chest X-ray findings required to obtain acceptable placement of the catheter tip.
Brachiocephalic Veins
;
Catheterization
;
Catheters*
;
Central Venous Catheters*
;
Dialysis*
;
Humans
;
Intensive Care Units
;
Jugular Veins
;
Middle Aged
;
Renal Dialysis
;
Shock, Septic
;
Thorax
6.Surgical Results of Third or More Cardiac Valve Operation.
Suk Ho SOHN ; Ho Young HWANG ; Kyung Hwan KIM ; Ki Bong KIM ; Hyuk AHN
The Korean Journal of Thoracic and Cardiovascular Surgery 2015;48(1):25-32
BACKGROUND: We evaluated operative outcomes after third or more cardiac operations for valvular heart disease, and analyzed whether pericardial coverage with artificial membrane is helpful for subsequent reoperation. METHODS: From 2000 to 2012, 149 patients (male:female=70:79; mean age at operation, 57.0+/-11.3 years) underwent their third to fifth operations for valvular heart disease. Early results were compared between patients who underwent their third operation (n=114) and those who underwent fourth or fifth operation (n=35). Outcomes were also compared between 71 patients who had their pericardium open during the previous operation and 27 patients who had artificial membrane coverage. RESULTS: Intraoperative adverse events occurred in 22 patients (14.8%). Right atrium (n=6) and innominate vein (n=5) were most frequently injured. In-hospital mortality rate was 9.4%. Total cardiopulmonary bypass time (225+/-77 minutes vs. 287+/-134 minutes, p=0.012) and the time required to prepare aortic cross clamp (209+/-57 minutes vs. 259+/-68 minutes, p<0.001) increased as reoperations were repeated. However, intraoperative event rate (13.2% vs. 20.0%), in-hospital mortality (9.6% vs. 8.6%) and postoperative complications were not statistically different according to the number of previous operations. Pericardial closure using artificial membrane at previous operation was not beneficial in reducing intraoperative events (25.9% vs. 18.3%) and shortening operation time preparing aortic cross clamp (248+/-64 minutes vs. 225+/-59 minutes) as compared to no-closure. CONCLUSION: Clinical outcomes of the third or more operations for valvular heart disease were acceptable in terms of intraoperative adverse events and in-hospital mortality rates. There were no differences in the incidence of intraoperative adverse events, early mortality and postoperative complications between third cardiac operation and fourth or more.
Brachiocephalic Veins
;
Cardiopulmonary Bypass
;
Heart Atria
;
Heart Valve Diseases
;
Heart Valves*
;
Hospital Mortality
;
Humans
;
Incidence
;
Membranes, Artificial
;
Mortality
;
Pericardium
;
Postoperative Complications
;
Reoperation
;
Sternum
7.Pacemaker Lead Fracture Treated with Splinting and Venoplasty.
Ji Eun KIM ; Nam Sik YOON ; Hyung Wook PARK ; Jeong Gwan CHO
Korean Journal of Medicine 2015;88(2):197-201
A 56-year-old man was admitted for pacemaker generator replacement. We identified a partial fracture in the proximal part of the lead just after the conjunction of the atrial and ventricular leads. The atrial lead sensitivity was stable even under intentional pulling and twisting. We deployed a splint made of a suture-sleeve in the fracture site. After burying the malfunctioning ventricular connector behind the pocket, we inserted only a new ventricular lead. However, another complication existed. Venogram showed a total occlusion between the brachiocephalic vein and superior vena cava. After meticulous wiring, we passed the target and dilated the vessel with 8 and 9 Fr dilators. Finally, a new ventricular lead and generator were inserted via a long peel-away sheath. In conclusion, we successfully treated a patient with a partial lead fracture and a brachiocephalic vein occlusion using splinting and venoplasty.
Angioplasty
;
Brachiocephalic Veins
;
Equipment Failure
;
Humans
;
Middle Aged
;
Splints*
;
Vena Cava, Superior
8.Internal Jugular Vein Thrombosis Presenting with Elevated Intraocular Pressure.
Journal of the Korean Ophthalmological Society 2015;56(11):1810-1816
PURPOSE: To report a case of elevated intraocular pressure (IOP) caused by internal jugular vein thrombosis. CASE SUMMARY: A 58-year-old male diagnosed with diabetic retinopathy visited our clinic for a regular checkup. On ophthalmic examination, IOP was 30 mm Hg in the right eye and 28 mm Hg in the left eye. Slit lamp examination showed chemosis, conjunctival injection and slight corneal edema in both eyes. Additionally, gonioscopic examination showed open angle. We observed face edema that started 1 month prior and he was diagnosed with internal jugular vein thrombosis on the right side, internal jugular vein and innominate vein stenosis on the left side approximately 2 months ago. The patient underwent percutanoeus transluminal angioplasty for dilating stenosed vessel. Four days after the procedure, his IOP was 15 mm Hg in the right eye and 12 mm Hg in the left eye based on Goldman applanation tonometer and was well maintained. CONCLUSIONS: Internal jugular vein thrombosis on both sides can cause an increase in IOP.
Angioplasty
;
Brachiocephalic Veins
;
Constriction, Pathologic
;
Corneal Edema
;
Diabetic Retinopathy
;
Edema
;
Humans
;
Intraocular Pressure*
;
Jugular Veins*
;
Male
;
Middle Aged
;
Thrombosis*
9.Novel Partial Anomalous Pulmonary Venous Connection Associated with Brain Abscess.
Anish KOKA ; Amit SACHDEV ; Moussa F YAZBECK ; Rodney D BELL ; Christopher FARRELLC
Journal of Clinical Neurology 2014;10(1):55-58
BACKGROUND: Right-to-left vascular shunts are associated with brain abscess. CASE REPORT: We present a 47-year-old female with a cryptogenic left thalamic abscess on which Streptococcus mitis grew upon aspiration. Computed tomography of the chest with contrast agent revealed an anomalous connection between the left superior pulmonary and brachiocephalic veins. A right-to-left shunt was confirmed in a transthoracic echocardiogram study in which bubbles were injected into the left arm; this shunt had not previously been noted upon right-arm injection. CONCLUSIONS: We recommend aggressive evaluation for right-to-left shunts in patients who present with cryptogenic brain abscesses. In addition to imaging, this should include a bubble-based study with left-arm saline injection.
Abscess
;
Arm
;
Brachiocephalic Veins
;
Brain Abscess*
;
Brain*
;
Female
;
Humans
;
Middle Aged
;
Streptococcus mitis
;
Thorax
10.Acute right heart failure caused by iatrogenic brachiocephalic arteriovenous fistula following orthopedic surgery.
Kye Hun KIM ; Hyun Ju YOON ; Youngkeun AHN ; Myung Ho JEONG ; Jeong Gwan CHO ; Jong Chun PARK ; Jung Chaee KANG
The Korean Journal of Internal Medicine 2014;29(4):529-531
No abstract available.
Acute Disease
;
Adult
;
Arteriovenous Fistula/diagnosis/*etiology/surgery
;
Brachiocephalic Trunk/*injuries/radiography/surgery/ultrasonography
;
Brachiocephalic Veins/*injuries/radiography/surgery/ultrasonography
;
Dislocations/*surgery
;
Echocardiography, Doppler, Color
;
Female
;
Heart Failure/diagnosis/*etiology
;
Humans
;
*Iatrogenic Disease
;
Orthopedic Procedures/*adverse effects
;
Reoperation
;
Sternoclavicular Joint/*surgery
;
Tomography, X-Ray Computed
;
Treatment Outcome
;
Vascular System Injuries/diagnosis/*etiology/surgery

Result Analysis
Print
Save
E-mail