1.Posterior Lower Cervical fixation with the AME Haid Universal Bone Plate System.
Journal of Korean Neurosurgical Society 1996;25(5):1017-1022
During posterior cervical stabilization, lateral mass fixation with plate-screw has been found to be a simple and safe application, without the dependence on intact posterior element and immediate rigid fixation. We applied the AME Haid Universal Bone Plate System to six cases of traumatic lower cervical instability with favorable results. Drilling direction was 30 degrees lateral and 15-20 degrees rostral to the vertebral plane, and we have not noticed any complication. Screw loosening, the pitfall of the procedure is described.
Bone Plates*
2.Internal fixation for the spine fusion using long bone plates and screws.
Joo Tae PARK ; Kil Yeong AHN ; Jung Ho YANG
The Journal of the Korean Orthopaedic Association 1991;26(4):1219-1225
No abstract available.
Bone Plates*
;
Spine*
3.The treatment of distal tibia shaft fracture using may anatomical bone plate.
Seung Gyun CHA ; Won Suck LEE ; Jin Hak KIM ; Woo Tae LEE
The Journal of the Korean Orthopaedic Association 1992;27(3):744-752
No abstract available.
Bone Plates*
;
Tibia*
4.A case report of the huge complex odontoma treated with the sagittal splitting of buccal bone plate and iliac bone graft in left mandible angle
Ho Seok KIM ; Jae Chul SONG ; Chin SOo KIM
Journal of the Korean Association of Maxillofacial Plastic and Reconstructive Surgeons 1994;15(4):269-274
No abstract available.
Bone Plates
;
Mandible
;
Odontoma
;
Transplants
5.Analysis of Revision Content and Evaluation Attentions on Guidance for Registration of Metallic Bone Plate Internal Fixation System (Revised in 2021).
Jing WU ; Le JIN ; Lihua DONG ; Dan HAN ; Xinli SHI
Chinese Journal of Medical Instrumentation 2023;47(3):312-316
This study briefly introduces the revised content of Guidance for Registration of Metallic Bone Plate Internal Fixation System (Revised in 2021) compared to the original guidance, mainly including the principles of dividing registration unit, main performance indicators of standard specification, physical and mechanical performance research, and clinical evaluation. At the same time, in order to provide some references for the registration of metallic bone plate internal fixation system, this study analyzes the main concerns in the review process of these products based on the accumulation of experience combining with the current review requirements.
Bone Plates
;
Fracture Fixation, Internal
;
Biomechanical Phenomena
8.Autologous grafts of double-strut fibular cortical bone plate to treat the fractures and defects of distal femur: a case report and review of literature.
Xu CHEN ; Jian-Jun LI ; Zhan KONG ; Dong-Xiang YANG ; Xiang-Nan YUAN
Chinese Journal of Traumatology 2011;14(4):241-246
We reported a 23-year-old man who was involved in a high-speed motorcycle accident. He sustained a closed fracture at the right distal femur. The primary fracture happened on February 2008. He underwent open reduction and internal fixation with cloverleaf plate. And one hundred days after the surgery, the proximal screws were pulled-out, but the bone union was not achieved. Treatment consisted of exchanging the cloverleaf plate with a locking compression plate and using an auto-iliac bone graft to fill the nonunion gap. In July 2009, the patient had a sharp pain in the right lower limb. The X-ray revealed that the plate implanted last year was broken, causing a nonunion at the fracture site. Immediately the plate and screws were removed and an intramedullary nail was inserted reversely from the distal femur as well as a 7 cm long bone from the right fibula was extracted and longitudinally split into two pieces to construct cortical bone plates. Then we placed them laterally and medially to fracture site, drilled two holes respectively, and fastened them with suture. We carried on auto-iliac bone grafting with the nonunion bone grafts. The follow-up at 15 months after operation showed that the treatment was successful, X-ray confirmed that there was no rotation and no angular or short deformity. We briefly reviewed the literature regarding such an unusual presentation and discussed in details the possible etiology and the advantages of autologous double-strut fibular grafts to cope with such an intractable situation.
Bone Plates
;
Femur
;
Fibula
;
Fracture Fixation, Internal
;
Fractures, Bone
;
Humans
10.Precise tooth preparation technique guided by 3D printing guide plate with quantitative hole.
Chun-Xu LIU ; Jing GAO ; Yu-Wei ZHAO ; Lin FAN ; Lu-Ming JIA ; Nan HU ; Zi-Yu MEI ; Bo DONG ; Qian-Qian ZHANG ; Hai-Yang YU
West China Journal of Stomatology 2020;38(3):350-355
The minimum amount of tooth preparation that can be fully controlled is crucial in achieving long-term, stable, and effective aesthetic restoration, which is also a major difficulty in aesthetic restoration. The tooth preparation can be imple-mented efficiently and accurately through digital technology based on the fixed-deep hole guiding technology. Prior the actual tooth preparation, the technology first designs the virtual contour, layering, and virtual occlusion of the prosthesis on the computer. Then, virtual tooth preparation is carried out by cutting back according to the virtual prosthesis. Next, the virtual drilling operation plan is designed according to the shape of the virtual tooth preparation and the contour of the abutment tooth. Finally, the tooth preparation guide plate is designed and printed in 3D. It realizes the whole process of quantitative and precise guidance of dental preparation, visualizes the restoration space, reduces the clinical operation time, and guarantees the quality of dental preparation. It also promotes the improvement of the teaching quality of digital practical exercises.
Bone Plates
;
Esthetics, Dental
;
Printing, Three-Dimensional
;
Tooth
;
Tooth Preparation