1.Value of cell block technique as an adjunct to smear cytology in thyroid fine-needle aspiration biopsy
Nichole Andrea Bisquera ; Oliver Allan Dampil ; Bernadette Diane Vista
Philippine Journal of Pathology 2025;10(1):1-8
BACKGROUND
Thyroid fine-needle aspiration biopsy (FNAB) is widely used for thyroid nodule characterization, with approximately 2.7% of samples classified as "inadequate." Non-diagnostic samples pose limitations, resulting in repeated procedures, and unnecessary diagnostic thyroidectomies. Conventional smear (CS) is commonly the method of choice for cytologic preparation of thyroid FNAB. The cell block technique is an alternative that concentrates cells providing additional material for better evaluation and ancillary testing. While conventional smears are commonly used, introducing routine complementary cell blocks could potentially lower costs associated with repeat procedures and improve patient management.
OBJECTIVEThe study aimed to investigate the diagnostic value of incorporating the cell block technique as adjunct to conventional smear technique in reducing nondiagnostic rates (Bethesda Category I) in thyroid-fine needle aspiration biopsies (FNAB) conducted in 2 private hospitals.
METHODOLOGYThis is a multi-center, retrospective cross-sectional study with 701 samples from 528 adult patients, who underwent thyroid FNAB between January 2020 - September 2022. The primary outcome of interest is the reduction in non-diagnostic rates with the combined use of conventional smears and cell block.
RESULTSThe non-diagnostic rates were significantly higher with cell block technique (28.10%) as compared to conventional smears (16.26%), p-value < .01. The results show that conventional smears have lower non-diagnostic rates. With smear cytology alone, 114 (16.3%) of all samples were nondiagnostic. With the addition of cell block technique, 15 of these samples were reclassified as benign (n = 13), Bethesda III (n = 1) or Bethesda IV (n = 1). The rest of the non-diagnostic samples (n = 99) remained Bethesda I. Overall, the equivalent decrease in non-diagnostic rate was 2.1%.
CONCLUSIONThe combined use of cell block and conventional smears did not significantly decrease nondiagnostic rates in thyroid FNAB. In general, conventional smears demonstrated superior diagnostic efficacy across all Bethesda categories, establishing it as the preferred sampling preparation method for thyroid FNAB. Cell blocks should be considered a supplementary technique, particularly in cases where ancillary methods like immunohistochemistry or molecular testing are needed.
Biopsy, Fine-needle ; Thyroid Nodule ; Thyroid Gland ; Thyroid Diseases
2.Application of Fine-Needle Aspiration in the Diagnosis of Classic Hodgkin Lymphoma and Its Clinical Pathological Analysis.
Lan CHEN ; Zhou-Ying LIU ; Zheng-Xian CHEN ; Jin-Song ZHANG
Journal of Experimental Hematology 2025;33(4):1047-1050
OBJECTIVE:
To analyze the cytologic characteristics fine-needle aspiration using histology as the gold standard and to evaluate its diagnostic application in classic Hodgkin lymphoma.
METHODS:
A retrospective analysis was conducted on 17 patients who underwent both coarse-needle aspiration and fine-needle aspiration and were histologically confirmed with classic Hodgkin lymphoma(CHL) at our hospital from December 2012 to December 2023. Clinical information of these patients was collected, and the smear morphology, immunocytochemistry and corresponding biopsies were reviewed.
RESULTS:
Among the 17 cases of CHL, there were 5 cases of mixed cellularity, 10 cases of nodular sclerosis and 2 cases were unsubtyped. Fifteen cases were correctly diagnosed by fine-needle aspiration, with an accuracy rate of 88.2%. The other two cases were misdiagnosed as non-Hodgkin lymphoma. Morphologically single dispersed mononuclear Hodgkin cells and multinucleated Reed-Sternberg cells were observed in a heterogenous background of lymphocytes in cytology smears, and these cells were positive for CD30 immunocytochemistry.
CONCLUSION
Fine needle aspiration is less invasive and quicker, and the cell morphology is better preserved as compared to histological biopsy. It is easier to recognize pathognomonic Hodgkin or Reed-Sternberg cells and it is helpful for the rapid diagnosis and clinical management of CHL.
Humans
;
Hodgkin Disease/pathology*
;
Biopsy, Fine-Needle
;
Retrospective Studies
;
Female
;
Immunohistochemistry
;
Male
3.Diagnostic yield and safety of pancreatic cystic lesions: A comparison between EUS-FNA and EUS-FNB.
Xiaoyu YU ; Mingmei YE ; Yawen NI ; Qianqi LIU ; Pan GONG ; Yuanyuan HUANG ; Xiaoyan WANG ; Li TIAN
Journal of Central South University(Medical Sciences) 2025;50(2):227-236
OBJECTIVES:
In recent years, the incidence and detection rate of pancreatic cystic lesions (PCLs) have increased significantly. Endoscopic ultrasound (EUS) plays an indispensable role in the diagnosis and differential diagnosis of PCLs. However, evidence comparing the diagnostic performance of EUS-guided fine-needle aspiration (EUS-FNA) and fine-needle biopsy (FNB) remains limited. This study aims to compare the diagnostic yield, adequacy of tissue acquisition, and safety between EUS-FNA and EUS-FNB in evaluating PCLs to inform clinical practice.
METHODS:
A retrospective review was conducted on patients with PCLs who underwent either EUS-FNA or EUS-FNB between January 2014 and August 2021. The diagnostic yield, tissue acquisition adequacy, and incidence of adverse events were compared between the 2 groups.
RESULTS:
A total of 90 patients with PCLs were included (52 in the FNA group and 38 in the FNB group). The diagnostic yield was similar between the FNA and FNB groups (94.2% vs 94.7%, P>0.05). The adequacy of tissue acquisition was 71.2% in the FNA group and 81.6% in the FNB group (P>0.05). No statistically significant difference was observed in the incidence of adverse events between the 2 groups (P>0.05).
CONCLUSIONS
Both EUS-FNA and EUS-FNB demonstrate equally high diagnostic yields and tissue adequacy in PCLs, with excellent safety profiles. Both methods are safe and effective diagnostic tools for evaluating PCLs.
Humans
;
Endoscopic Ultrasound-Guided Fine Needle Aspiration/adverse effects*
;
Retrospective Studies
;
Female
;
Male
;
Pancreatic Cyst/diagnostic imaging*
;
Middle Aged
;
Biopsy, Fine-Needle/adverse effects*
;
Aged
;
Pancreatic Neoplasms/diagnosis*
;
Adult
;
Endosonography/methods*
;
Pancreas/pathology*
;
Diagnosis, Differential
4.A rare case report of moderately differentiated adenosquamous carcinoma in the parotid gland associated with IgG4-related disease and literature review.
Huarong PANG ; Qiuping LU ; Zhangmo HUANG ; Jiejun YANG ; Qingyun XIE ; Biru ZHANG
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(8):749-753
Objective:To explore the clinical manifestations of IgG4-related diseases(IgG4-RD) complicated with moderately differentiated adenosquamous carcinoma of the parotid gland, the diagnostic criteria for IgG4-related diseases and parotid malignant tumors, treatment regimens, and the application of fine-needle aspiration in disease diagnosis, so as to reduce clinical misdiagnosis and missed diagnosis. Methods:A retrospective analysis was conducted on the case data of a patient with IgG4-related diseases(IgG4-RD) complicated with moderately differentiated adenosquamous carcinoma of the parotid gland admitted to our department in March 2024. The clinical characteristics, imaging findings, preoperative puncture results, and postoperative pathological features were analyzed, and relevant literatures on both diseases were reviewed and summarized. Results:The elderly male patient was admitted due to "a mass in the parotid area in front of the right ear for more than 3 months". Through clinical examination, imaging examination, laboratory examination, and preoperative needle biopsy, the diagnosis of "right parotid moderately differentiated adenosquamous carcinoma complicated with IgG4-related disease" was considered. It was also considered that IgG4-related disease did not involve other organs before surgery, so no systemic hormone therapy was given before or after surgery. After surgery combined with postoperative radiotherapy, follow-up showed that neither the parotid tumor nor IgG4-related disease recurred. Conclusion:"IgG4-related disease complicated with moderately differentiated adenosquamous carcinoma"is a rare clinical disease. Both lack typical clinical manifestations and specific imaging features, and the diagnosis is mostly unclear before surgery. Pathological examination is of great significance in the diagnosis of the disease, while fine-needle aspiration has limited value in the diagnosis, which should attract the attention of clinicians. In addition, for patients with both diseases, individualized treatment plans should be formulated.
Humans
;
Parotid Neoplasms/pathology*
;
Male
;
Carcinoma, Adenosquamous/pathology*
;
Immunoglobulin G4-Related Disease/complications*
;
Parotid Gland/pathology*
;
Retrospective Studies
;
Aged
;
Biopsy, Fine-Needle
;
Immunoglobulin G
5.Cellular and Histopathological Characteristics of Ultrasonically Underdiagnosed 3/4a Thyroid Nodules.
Wu WEI-QI ; Xu CUN-BAO ; Li YOU-JIA ; Su CHUN-YANG ; Feng-Shun ZHANG ; Yi-Feng CHEN
Acta Academiae Medicinae Sinicae 2025;47(1):23-28
Objective To analyze the cellular and histopathological characteristics of underdiagnosed thyroid nodules of Chinese thyroid imaging reporting and data system(C-TIRADS) categories 3 and 4a,thus improving the understanding of these lesions. Methods The data of ultrasound and fine needle aspiration cytology were collected from 683 nodules diagnosed based on pathological evidence in 549 patients undergoing thyroid surgery.The cellular and histopathological characteristics of C-TIRADS 3 and 4a nodules were analyzed. Results Two hundred and sixty-eight nodules were classified as C-TIRADS category 3,including 236 benign nodules,12 low-risk ones,and 20 (7.46%) malignant ones.Two hundred and twenty-one nodules were classified as C-TIRADS category 4a,including 133 benign nodules,7 low-risk ones,and 81 (36.65%) malignant ones.The malignancy rates differed between C-TIRADS 3 and 4a nodules (χ2=58.93,P<0.001),and both were higher than the recommended malignancy rate in the guidelines for malignancy risk stratification of thyroid nodules (C-TIRADS) (both P<0.001).According to the pathological evidence,the underdiagnosed C-TIRADS 3/4a nodules were mainly papillary thyroid carcinoma,especially in patients with Hashimoto thyroiditis.There was not a consistent one-to-one match between each ultrasound result and each cytological classification of low-risk thyroid nodules.Conclusions When the malignant features in preoprative ultrasound imaging are atypical or absent,papillary thyroid carcinoma (especially with Hashimoto thyroiditis),follicular carcinoma,and medullary carcinoma are likely to be underdiagnosed as C-TIRADS 3 or 4a nodules.Therefore,efforts should be made to fully understand the cellular and pathological characteristics of these lesions.
Humans
;
Thyroid Nodule/diagnostic imaging*
;
Female
;
Male
;
Middle Aged
;
Adult
;
Ultrasonography
;
Biopsy, Fine-Needle
;
Aged
;
Young Adult
;
Thyroid Neoplasms/diagnostic imaging*
;
Adolescent
7.Cytology Smears of Rapid On-site Evaluation as Supplemental Material for Molecular Testing of Non-small Cell Lung Cancer.
Shiqi TANG ; Chunli TANG ; Zeyun LIN ; Juhong JIANG
Chinese Journal of Lung Cancer 2024;26(12):910-918
BACKGROUND:
The thoracic small biopsy sampling procedure including transbronchial forceps lung biopsy (TBLB) and endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) can be accompanied by rapid on-site evaluation (ROSE) of sample material to provide immediate feedback for the proceduralist. The present study aims to investigate the supplemental effect of ROSE smear samples for lung cancer molecular test.
METHODS:
In a retrospective study, 308 patients admitted to our hospital from August 2020 to December 2022 undergoing diagnostic TBLB and EBUS-TBNA with ROSE and subsequently diagnosed as non-small cell lung cancer (NSCLC) were analyzed. The matched formalin-fixed paraffin-embedding (FFPE) tissue section and ROSE smears for tumor cellularity were compared. DNA yields of smears were determined. Real-time polymerase chain reaction (PCR) and next-generation sequencing (NGS) were performed on adequate smear samples.
RESULTS:
ROSE smear samples were enriched in tumor cells. Among 308 biopsy samples, 78 cases (25.3%) exhibited inadequate FFPE tissue sections, whereas 44 cases (14.3%) yielded adequate smear samples. Somatic mutations detected in the FFPE tissue section samples were also detected in the matching adequate smear sample.
CONCLUSIONS
ROSE smear samples of the thoracic small biopsies are beneficial supplemental materials for ancillary testing of lung cancer. Combined use of cytology smear samples with traditional FFPE section samples can enhance the detection rate of informative mutations in patients with advanced NSCLC. We recommend that the laboratory could further evaluate the ROSE cell smears of the patient when FFPE tissue sections are inadequate, and that adequate cell smears can be used as a supplemental source for the molecular testing of NSCLC.
Humans
;
Carcinoma, Non-Small-Cell Lung/pathology*
;
Lung Neoplasms/pathology*
;
Rapid On-site Evaluation
;
Retrospective Studies
;
Molecular Diagnostic Techniques
;
Endoscopic Ultrasound-Guided Fine Needle Aspiration/methods*
10.Influencing Factors and Prediction Model of Performance of Needle Visualization in Fine Needle Aspiration of Thyroid Nodules.
Liang-Kai WANG ; Jia-Jia TANG ; Wen-Quan NIU ; Xin-Ying JIA ; Xue-Hua XI ; Jiao-Jiao MA ; Hui-Lin LI ; Zhe SUN ; Xin-Yi LIU ; Bo ZHANG
Acta Academiae Medicinae Sinicae 2023;45(3):366-373
Objective To investigate the influencing factors and establish a model predicting the performance of needle visualization in fine-needle aspiration (FNA) of thyroid nodules. Methods This study prospectively included 175 patients who underwent FNA of thyroid nodules in the Department of Ultrasound in China-Japan Friendship Hospital and compared the display of the needle tips in the examination of 199 thyroid nodules before and after the application of needle visualization.We recorded the location,the positional relationship with thyroid capsule,ultrasonic characteristics,and the distribution of the soft tissue strip structure at the puncture site of the nodules with unclear needle tips display before using needle visualization.Furthermore,according to the thyroid imaging reporting and data system proposed by the American College of Radiology,we graded the risk of the nodules.Lasso-Logistic regression was employed to screen out the factors influencing the performance of needle visualization and establish a nomogram for prediction. Results The needle tips were not clearly displayed in the examination of 135 (67.8%) and 53 (26.6%) nodules before and after the application of needle visualization,respectively,which showed a significant difference (P<0.001).Based on the positional relationship between the nodule and capsule,anteroposterior/transverse diameter (A/T) ratio,blood supply,and the distribution of subcutaneous strip structure at the puncture site,a nomogram was established to predict the probability of unclear display of the needle tips after application of needle visualization.The C-index of the prediction model was 0.75 (95%CI=0.67-0.84) and the area under the receiver operating characteristic curve was 0.72.The calibration curve confirmed the appreciable reliability of the prediction model,with the C-index of 0.70 in internal validation. Conclusions Needle visualization can improve the display of the needle tip in ultrasound-guided FNA of thyroid nodules.The nomogram established based on ultrasound features such as the positional relationship between the nodule and capsule,A/T ratio,blood supply,and the distribution of subcutaneous strip structure at the puncture site can predict whether needle visualization is suitable for the examination of nodules.
Humans
;
Thyroid Nodule/diagnostic imaging*
;
Biopsy, Fine-Needle/methods*
;
Reproducibility of Results
;
Ultrasonography
;
Retrospective Studies
;
Thyroid Neoplasms


Result Analysis
Print
Save
E-mail