1.Clinical value of continuous photoplethysmography algorithms for detection of atrial fibrillation by wearable devices
Qifan LI ; Song ZUO ; Yiwei LAI ; Sitong LI ; Caihua SANG ; Xin DU ; Jianzeng DONG ; Changsheng MA
Chinese Journal of Cardiology 2024;52(5):513-518
Objective:To evaluate the accuracy of continuous photoplethysmography algorithms for atrial fibrillation diagnosis and atrial fibrillation burden evaluation via wearable devices.Methods:This study was a self-controlled prospective cohort study. A total of 254 consecutive inpatients were recruited from the Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University from September 2022 to November 2022. All participants were required to wear two devices at the same time: (1) an electrocardiogram (ECG) watch for acquisition of photoplethysmography (watch-recorded-photoplethysmography, W-PPG) and electrocardiogram (watch-recorded-electrocardiogram, W-ECG); (2) an ECG patch for acquisition of electrocardiogram (patch-recorded-electrocardiogram, P-ECG). The results were measured in 30 s data segments and individual participants, separately, which were calculated for sensitivity and specificity by comparing them with the results of expert-read ECG according to the receiver operating characteristic curve. Four groups were separated according to the proportion of the atrial fibrillation burden, and the difference of atrial fibrillation burden from algorithm and expert-read ECG was calculated.Results:All 254 subjects completed the study. The mean age of participants was (63.04±11.04) years old, 99 (38.98%) of them were female, and 97 (38.19%) patients had persistent atrial fibrillation. Expert-read ECG results were taken as standard criteria in all calculations. The P-ECG algorithm had a sensitivity of 94.86% (95% CI: 94.81%-94.91%) and a specificity of 99.30% (95% CI: 99.28%-99.31%) when measured in data segments. The W-PPG algorithm had a sensitivity of 96.07% (95% CI: 95.97%-96.18%) and a specificity of 98.62% (95% CI: 98.59%-98.65%). When measured in terms of individual participants, the P-ECG algorithm had a sensitivity of 92.55% (95% CI: 87.57%-95.71%) and a specificity of 96.39% (95% CI: 93.45%-98.09%), while the W-PPG algorithm had a sensitivity of 93.71% (95% CI: 88.75%-96.67%) and a specificity of 89.62% (95% CI: 85.61%-92.65%). When measured in terms of a single acquisition of W-ECG records, the W-ECG algorithm had a sensitivity of 92.04% (95% CI: 88.14%-94.78%) and a specificity of 96.19% (95% CI: 94.35%-97.47%). For atrial fibrillation burden assessment, the difference between the W-PPG analysis results and the expert-read ECG results was less than 2% in all burden distribution intervals. Conclusions:Continuous photoplethysmography algorithm applied to wearable devices to detect atrial fibrillation is a feasible strategy. Taking expert-read ECG results as standard, continuous monitoring of PPG by a smartwatch is highly accurate for atrial fibrillation diagnosis and can also be used to effectively complete atrial fibrillation burden assessment.
2.Early experience with mechanical hemodynamic support for catheter ablation of malignant ventricular tachycardia
Mengmeng LI ; Yang YANG ; Deyong LONG ; Chenxi JIANG ; Ribo TANG ; Caihua SANG ; Wei WANG ; Xin ZHAO ; Xueyuan GUO ; Songnan LI ; Changyi LI ; Man NING ; Changqi JIA ; Li FENG ; Dan WEN ; Hui ZHU ; Yuexin JIANG ; Fang LIU ; Tong LIU ; Jianzeng DONG ; Changsheng MA
Chinese Journal of Cardiology 2024;52(7):768-776
Objective:To explore the role of mechanical hemodynamic support (MHS) in mapping and catheter ablation of patients with hemodynamically unstable ventricular tachycardia (VT), report single-center experience in a cohort of consecutive patients receiving VT ablation during MHS therapy, and provide evidence-based medical evidence for clinical practice.Methods:This was a retrospective cohort study. Patients with hemodynamically unstable VT who underwent catheter ablation with MHS at Beijing Anzhen Hospital, Capital Medical University between August 2021 and December 2023 were included. Patients were divided into rescue group and preventive group according to the purpose of treatment. Their demographic data, periprocedural details, and clinical outcomes were collected and analyzed.Results:A total of 15 patients with hemodynamically unstable VT were included (8 patients in the rescue group and 7 patients in the preventive group). The acute procedure was successful in all patients. One patient in the rescue group had surgical left ventricular assist device (LVAD) implantation, remaining 14 patients received extracorporeal membrane oxygenation (ECMO) for circulation support. ECMO decannulation was performed in 12 patients due to clinical and hemodynamic stability, of which 6 patients were decannulation immediately after surgery and the remaining patients were decannulation at 2.0 (2.5) d after surgery. Two patients in the rescue group died during the index admission due to refractory heart failure and cerebral hemorrhage. During a median follow-up of 30 d (1 d to 12 months), one patient with LVAD had one episode of ventricular fibrillation at 6 months after discharge, and no further episodes of ventricular fibrillation and/or VT occurred after treatment with antiarrhythmic drugs. No malignant ventricular arrhythmia occurred in the remaining 12 patients who were followed up.Conclusions:MHS contributes to the successful completion of mapping and catheter ablation in patients with hemodynamically unstable VT, providing desirable hemodynamic status for emergency and elective conditions.
3.Analysis factors influencing left ventricular thrombus in patients with non-ischemic heart failure
Zhiyan WANG ; Hao ZHANG ; Wenjie LI ; Chang HUA ; Yangyang TANG ; Xinru LIU ; Yuling XIONG ; Qiang LYU ; Jianzeng DONG ; Xin DU
Chinese Journal of Cardiology 2024;52(10):1155-1161
Objective:To explore the influencing factors of left ventricular thrombus (LVT) in patients with non-ischemic heart failure (NIHF) and to construct a nomogram prediction model for NIHF patients with LVT.Methods:This study was a case-control study. A total of 2 592 patients with NIHF hospitalized in Beijing Anzhen Hospital affiliated to Capital Medical University from January 2018 to July 2022 were selected. Fifty-one patients with LVT identified by echocardiography and cardiac magnetic resonance were classified into LVT group. One hundred and sixty patients were selected as the non-LVT group using a 1∶3 propensity score matching based on age and gender. Multivariate logistic regression analysis was used to explore the influencing factors of LVT in patients with NIHF. A nomogram prediction model was constructed, and the area under (AUC) the receiver operating characteristic (ROC) curve was calculated to evaluate the predictive effect of the model.Results:A total of 211 patients were enrolled, with a median age of 40 years old and 160 males (76%). Compared with non-LVT group, LVT group had lower systolic blood pressure ((112±20) mmHg vs. (120±19) mmHg; 1 mmHg=0.133 kPa), lower left ventricular ejection fraction (LVEF; (27±12)% vs. (39±14)% ), lower proportion of patients with history of hypertension (28% (14/51) vs. 44% (70/160)) and atrial fibrillation (8% (4/51)vs.39% (62/160)), higher proportion of patients with New York Heart Association functional class Ⅲ to Ⅳ (class Ⅲ: 59% (30/51) vs. 41% (66/160); class Ⅳ: 28% (14/51) vs. 19% (31/160)), and larger left ventricular end-systolic diameter (LVESD; (56±14) mm vs. (50±15) mm). The levels of hemoglobin ((152±23) g/L vs. (142±30) g/L), D-dimer (508 (300, 1 105) μg/L vs. 158 (68, 379) μg/L), and N-terminal pro-brain natriuretic peptide (3 429 (2 462, 4 734) ng/L vs. 1 288 (422, 2 544) ng/L) were higher in LVT group than in non-LVT group ( P all<0.05). LVT group had a higher proportion of patients using beta-blockers (92% (47/51) vs. 78% (124/160)), angiotensin-converting enzyme inhibitors or angiotensin receptor blockers or angiotensin receptor neprilysin inhibitors (88% (45/51) vs. 72% (115/160)), and anticoagulant drugs (98% (50/51) vs. 32% (51/160)) than non-LVT group (all P <0.05). Multivariate logistic regression showed that reduced LVEF ( OR=1.08, 95% CI 1.02-1.15, P=0.008), decreased LVESD ( OR=1.07, 95% CI 1.01-1.12, P=0.013), and increased D-dimer levels ( OR=5.40, 95% CI 1.98-14.74, P=0.001) were independent influencing factors for LVT in patients with NIHF. The ROC curve showed that the AUC of the nomogram for predicting LVT in patients with NIHF was 0.793 (95% CI 0.710-0.876, P<0.001). Conclusion:Reduced LVEF, decreased LVESD, and elevated D-dimer are associated with LVT in NIHF patients. The predictive model developed based on the above indicators has certain value in predicting LVT in NIHF patients.
4.Oral anti-coagulants use in Chinese hospitalized patients with atrial fibrillation
Jing LIN ; Deyong LONG ; Chenxi JIANG ; Caihua SANG ; Ribo TANG ; Songnan LI ; Wei WANG ; Xueyuan GUO ; Man NING ; Zhaoqing SUN ; Na YANG ; Yongchen HAO ; Jun LIU ; Jing LIU ; Xin DU ; Louise MORGAN ; C. Gregg FONAROW ; C. Sidney SMITH ; Y.H. Gregory LIP ; Dong ZHAO ; Jianzeng DONG ; Changsheng MA
Chinese Medical Journal 2024;137(2):172-180
Background::Oral anti-coagulants (OAC) are the intervention for the prevention of stroke, which consistently improve clinical outcomes and survival among patients with atrial fibrillation (AF). The main purpose of this study is to identify problems in OAC utilization among hospitalized patients with AF in China.Methods::Using data from the Improving Care for Cardiovascular Disease in China-Atrial Fibrillation (CCC-AF) registry, guideline-recommended OAC use in eligible patients was assessed.Results::A total of 52,530 patients with non-valvular AF were enrolled from February 2015 to December 2019, of whom 38,203 were at a high risk of stroke, 9717 were at a moderate risk, and 4610 were at a low risk. On admission, only 20.0% (6075/30,420) of patients with a diagnosed AF and a high risk of stroke were taking OAC. The use of pre-hospital OAC on admission was associated with a lower risk of new-onset ischemic stroke/transient ischemic attack among the diagnosed AF population (adjusted odds ratio: 0.54, 95% confidence interval: 0.43–0.68; P <0.001). At discharge, the prescription rate of OAC was 45.2% (16,757/37,087) in eligible patients with high stroke risk and 60.7% (2778/4578) in eligible patients with low stroke risk. OAC utilization in patients with high stroke risk on admission or at discharge both increased largely over time (all P <0.001). Multivariate analysis showed that OAC utilization at discharge was positively associated with in-hospital rhythm control strategies, including catheter ablation (adjusted odds ratio [OR] 11.63, 95% confidence interval [CI] 10.04–13.47; P <0.001), electronic cardioversion (adjusted OR 2.41, 95% CI 1.65–3.51; P <0.001), and anti-arrhythmic drug use (adjusted OR 1.45, 95% CI 1.38–1.53; P <0.001). Conclusions::In hospitals participated in the CCC-AF project, >70% of AF patients were at a high risk of stroke. Although poor performance on guideline-recommended OAC use was found in this study, over time the CCC-AF project has made progress in stroke prevention in the Chinese AF population.Registration::ClinicalTrials.gov, NCT02309398.
5.An Exploratory Study on the Effects of Interatrial Shunt for Patients With Heart Failure With Reduced Ejection Fraction
Sanshuai CHANG ; Wenhui WU ; Xinmin LIU ; Zhengming JIANG ; Yutong KE ; Qiang LYU ; Xin DU ; Jianzeng DONG ; Guangyuan SONG
Chinese Circulation Journal 2024;39(10):989-996
Objectives:To explore the effects of interatrial shunt on cardiac function and clinical prognosis of patients with heart failure with reduced ejection fraction(HFrEF). Methods:This study was a prospective single-arm study.From December 2021 to December 2022,15 consecutive patients with HFrEF from Beijing Anzhen Hospital were enrolled in this study.Interatrial shunt was performed with a D-Shant atrial shunt device.Right heart catheterization was performed before and immediately after device implantation,pulmonary capillary wedge pressure(PCWP),mean right atrial pressure(RAP),interatrial gradient pressure,mean pulmonary artery pressure,total pulmonary resistance(TPR),pulmonary vascular resistance(PVR),cardiac index(CI),and pulmonary/systemic blood flow ratio(Qp/Qs)were measured.Patients were followed-up for 12 months after procedure,changes in cardiac structure and function were evaluated by echocardiography.NYHA classification,6-minute walking distance(6MWD),and Kansas City cardiomyopathy questionnaire(KCCQ)were observed.All-cause mortality and rehospitalization for heart failure served as clinical endpoints. Results:Interatrial shunt procedure was successful in all patients.Compared with preoperative value,PCWP,interatrial gradient pressure,mean pulmonary artery pressure,and TPR were significantly decreased,while Qp/Qs was significantly increased immediately after procedure(all P<0.01).There were no significant changes in RAP,PVR,and CI post procedure(all P>0.05).There were no significant differences in shunt size,shunt velocity,and shunt pressure difference between postoperative immediately and at 12-months follow-up(all P>0.05).At 12 months,left ventricular ejection fraction was significantly higher than baseline level(P<0.05),and there were no significant changes in right atrial diameter and right ventricular fractional area change(both P>0.05).Compared with preoperative status,NYHA classification was improved,KCCQ score was increased,and the number of patients with 6MWD>450 m was increased at 12 months(all P<0.05).N-terminal pro-B-type natriuretic peptide value was significantly decreased at 12 months(P<0.05).No patient died during the 12-months follow-up period,and there were no device-related adverse events.Two patients experienced hospital readmission for heart failure. Conclusions:Implantation of interatrial shunt device could effectively improve hemodynamic parameters in patients with HFrEF and is related to significantly improved cardiac function at 12-months follow-up.
6.Correlation Between Mitral Annular Calcification and Recurrence of Atrial Fibrillation After Radiofrequency Ablation
Jia XUE ; Bing LI ; Chenxi JIANG ; Wei WANG ; Ribo TANG ; Deyong LONG ; Jianzeng DONG ; Yan YAO
Chinese Circulation Journal 2023;38(12):1274-1278
Objectives:To explore the correlation between mitral annulus calcification(MAC)and recurrence of atrial fibrillation(AF)after radiofrequency ablation. Methods:The study included 785 patients with AF who underwent radiofrequency ablation in Beijing Anzhen Hospital from January 1,2019 to December 31,2020.According to the recurrence of AF after operation,patients were divided into recurrence group and non-recurrence group.Univariate Cox regression model was used to analyze the risk factors associated with AF recurrence,and multivariate Cox regression model was used to evaluate the influence of MAC on AF recurrence. Results:The average follow-up was(16±10)months.190 patients(24.2%)in the recurrence group,595(75.8%)patients in the non-recurrence.Patients in the recurrence group were older,had a higher proportion non-paroxysmal AF,a higher proportion of MAC,moderate/severe mitral regurgitation and larger left atrial diameter(LAD),and higher CHA2DS2-VASc score(all P<0.001).Univariate analysis showed that MAC was a risk factor of AF recurrence after radiofrequency ablation(HR=2.530,95%CI:1.639-3.907,P<0.001).After adjusting for age and sex,MAC remained significantly associated with an increased risk of AF recurrence after radiofrequency ablation(HR=1.52,95%CI:1.14-2.17,P<0.001).After multivariate adjustment for age,sex,non-paroxysmal AF,hypertension,diabetes,LAD,moderate/severe mitral regurgitation,and CHA2DS2-VASc score,MAC remained as an independent risk factor of AF recurrence(HR=1.48,95%CI:1.13-1.95,P=0.001). Conclusions:MAC is significantly associated with an increased risk of AF recurrence after radiofrequency ablation.
7.ABC-AF-Stroke score predicts thromboembolism in non-anticoagulated patients following successful atrial fibrillation ablation: a report from the Chinese Atrial Fibrillation Registry.
Yufeng WANG ; Chao JIANG ; Liu HE ; Xin DU ; Xueyuan GUO ; Ribo TANG ; Caihua SANG ; Deyong LONG ; Jianzeng DONG ; Ziad HIJAZI ; Gregory Y H LIP ; Changsheng MA
Chinese Medical Journal 2023;136(20):2451-2458
BACKGROUND:
The age, biomarkers, and clinical history (ABC)-atrial fibrillation (AF)-Stroke score have been proposed to refine stroke risk stratification, beyond what clinical risk scores such as the CHA2DS2-VASc score can offer. This study aimed to identify risk factors associated with thromboembolism and evaluate the performance of the ABC-AF-Stroke score in predicting thromboembolism in non-anticoagulated AF patients following successful ablations.
METHODS:
A total of 2692 patients who underwent successful ablations with discontinued anticoagulation after a 3-month blanking period in the Chinese Atrial Fibrillation Registry (CAFR) between 2013 and 2019 were included. Cox regression analysis was conducted to present the association of risk factors with thromboembolism risk. The ABC-AF-Stroke score was evaluated in terms of discrimination, including concordance index (C-index), net reclassification improvement (NRI) and integrated discrimination improvement (IDI), clinical utilization by decision curve analysis (DCA), and calibration by comparing the predicted risk with the observed annualized event rate.
RESULTS:
After a median follow-up of 3.5 years, 64 patients experienced thromboembolism events. Age, prior history of stroke/transient ischemic attack (TIA), high-sensitivity cardiac troponin T (cTnT-hs), and N-terminal pro-B-type natriuretic peptide (NT-proBNP) were independently associated with thromboembolism risk. The ABC-AF-Stroke score performed statistically significantly better than the CHA2DS2-VASc score in terms of C-index (0.67, 95% confidence interval [CI]: 0.59-0.74 vs. 0.60, 95% CI: 0.52-0.67, P = 0.030) and reclassification capacity. The DCA implied that the ABC-AF-Stroke score could identify more thromboembolism events without increasing the false positive rate compared to the CHA2DS2-VASc score. The calibration curve showed that the ABC-AF-Stroke score was well calibrated in this population.
CONCLUSIONS
In this real-world study enrolling non-anticoagulated AF patients following successful ablations, age, prior history of stroke/TIA, level of NT-proBNP, and cTnT-hs were independently associated with an increased risk of thromboembolism. The ABC-AF-Stroke score was well-calibrated and statistically significantly outperformed the CHA2DS2-VASc score in predicting thromboembolism risk.
Humans
;
Anticoagulants/therapeutic use*
;
Atrial Fibrillation/complications*
;
East Asian People
;
Ischemic Attack, Transient
;
Registries
;
Risk Assessment
;
Risk Factors
;
Stroke/etiology*
;
Thromboembolism/etiology*
;
Troponin T
8.Pharmacoeconomic evaluation of empagliflozin in the treatment of heart failure with reduced ejection fraction
Yiming WAN ; Haiqiang SANG ; Jianzeng DONG ; Yuchen JIA ; Huihui MA ; Yaohui JIANG
China Pharmacy 2022;33(1):74-78
OBJECTIVE To conduct the pharmacoeconomic evaluation of empagliflozin in the treatment of heart failure with reduced ejection fraction (HFrEF),and to provide evidence-based reference for rational drug use and medical and healthy decision-making. METHODS A Markov model was used to perform a cost-effectiveness analysis of the regimen of empagliflozin in the treatment of HFrEF ,and to evaluate the cost and effectiveness of standard treatment plan plus empagliflozin (empagliflozin group)vs. standard treatment plan (standard treatment group ). Clinical parameters were obtained from the EMPEROR-Reduced study;cost and utility data came from the published literatures. The cycle of the model was 1 month and the simulation time was 20 years. Single-factor sensitivity analysis and probability sensitivity analysis were performed to validate the results of cost-effectiveness analysis. RESULTS Compared with the standard treatment group ,each additional quality-adjusted life year in the empagliflozin group cost 37 995.94 yuan more ,which was less than China ’s 1 time GDP per capita in 2020(72 447 yuan). The results of single factor sensitivity analysis showed that steady-state hospitalization rate of 2 groups was the most important factor affecting the incremental cost-effectiveness ratio . The results of probability sensitivity analysis showed that when the willingness-to-pay threshold (WTP)was 1 time GDP per capita in 2020(72 447 yuan),the probability of empagliflozin group with cost-effectiveness advantage was 58.8%;when the WTP was 3 times GDP per capita in 2020(217 341 yuan),the probability of empagliflozin group with cost-effectiveness advantage was 63.8%. CONCLUSIONS Compared with standard treatment plan alone,standard treatment plan plus empagliflozin is more cost-effective in the treatment of HFrEF. However ,the economic probability is not high.
9.The impact of digoxin on the long-term outcomes in patients with coronary artery disease and atrial fibrillation
Yan QIAO ; Yue WANG ; Chenxi JIANG ; Songnan LI ; Caihua SANG ; Ribo TANG ; Deyong LONG ; Jiahui WU ; Liu HE ; Xin DU ; Jianzeng DONG ; Changsheng MA
Chinese Journal of Internal Medicine 2021;60(9):797-805
Objective:To investigate the long-term safety of digoxin in patients with coronary artery disease (CAD) and atrial fibrillation (AF).Methods:This was a prospective study, in which 25 512 AF patients were enrolled from China Atrial Fibrillation Registry Study. After exclusion of patients receiving ablation therapy at the enrollment, 1 810 CAD patients [age: (71.5±9.3)years] with AF were included. The subjects were grouped into the digoxin group and non-digoxin group, and were followed up for a period of 80 months. Long-term outcomes were compared between the groups and an adjusted Cox regression analysis was applied to evaluate the risk of digoxin on the long-term outcomes. The primary endpoint was all-cause mortality.Results:The patients were followed up for a median period of 3.05 years. After multivariable adjustment, the Cox regression analysis showed that digoxin significantly increased the risk of all-cause mortality ( HR=1.28, 95% CI 1.01-1.61, P=0.038), cardiovascular mortality ( HR=1.48,95% CI 1.10-2.00, P=0.010), cardiovascular hospitalization ( HR=1.67,95% CI 1.35-2.07, P=0.008) and the composite endpoints ( HR=2.02,95% CI 1.71-2.38, P<0.001). In the subgroup of patients with heart failure (HF), digoxin was not associated with the risk of all-cause mortality, but was still associated with the increased risk of cardiovascular mortality ( HR=1.44,95% CI 1.05-1.98, P=0.025), cardiovascular hospitalization ( HR=1.44,95% CI 1.09-1.90, P=0.010) and the composite endpoints ( HR=1.37, 95% CI 1.01-1.70, P=0.004). However, in the subgroup of patients without HF, digoxin was only associated with all-cause mortality ( HR=2.56,95% CI 1.44-4.54, P=0.001). Conclusion:Digoxin significantly increased the risk of all-cause mortality in CAD patients with AF, especially in patients without HF.
10.Clinical analysis of left atrial appendage occlusion for stroke prevention in elderly patients with atrial fibrillation
Wenli DAI ; Ran YANG ; Pengfei GUO ; Chao JIANG ; Yiwei LAI ; Yan ZHANG ; Jiahui WU ; Xu LI ; Songnan LI ; Rong BAI ; Xin DU ; Jianzeng DONG ; Changsheng MA
Chinese Journal of Internal Medicine 2021;60(9):822-826
To evaluate the efficacy and safety of left atrial appendage occlusion (LAAO) in patients with atrial fibrillation (AF) over 75 years. A total of 82 patients with AF who underwent LAAO successfully in Beijing Anzhen Hospital from March 2014 to March 2019 were divided into two groups according to age: the elderly group (aged>75 years) and the young group (aged ≤75 years). Risk of perioperative complications and incidence of ischemic stroke and major bleeding during follow-up were retrospectively analyzed. The results showed that there were no significant differences in procedure-related ischemic stroke(0 vs.1.6%, P=0.768) and major bleeding (0 vs.1.6%, P=0.768) during perioperative period between the two groups. No complications as death or pericardial tamponade occurred in the two group. During a (25.9±15.9) months period of followed up, ischemic stroke event rate was 3.6/100 person-years in the elderly group and 4.9/100 person-years in the young group, respectively. Major bleeding event rate was 2.5/100 person-years in the elderly group and 0/100 person-years in the young group, respectively. Compared with the expected ones, the relative risk reduction (RRR) of stroke in the elderly group was more profound than that in the young group (32.0% vs. 25.0%), while the risk of major bleeding in the young group was significantly lower than that in the elderly group (RRR 100% vs. 56.9%). Therefore, LAAO might be suitable for stroke prevention in the elderly AF patients.

Result Analysis
Print
Save
E-mail